Loading...
HomeMy WebLinkAbout0094155-Building (sunroom) 1 ~~h~~~~~~ane I 20'-( II SlAn IOO\rv"l 16' -0" tJhA17~ d"p; .&J $-{ cC/ La!- ~ 6f#t?5 .ad Symmetrica@ Unregistered Demonstration Version Copyright @ 1995-1997, Software Engineering, Inc. . ~ d? I'S. \L('C' - 48" Frost Walls on top of 8" thick footers 4 " Thick Concrete Slab as Floor Framing To Be Wood With 6" Walls ~,-~c.. - ~~ t..:Jo \~ t0~ '?~ ~ \%ss )-h~~ ~ .ad Symrtletrica@ Unregistered Demonstration Version Copyright@ 1995-]997, Software Engineering, Inc. . C 0:: < o a::l t.:.l' o C 0:: CIl t.:.l 1= 11.8::1 07 02 12: 40p ~'!: Freedom Lumber (920)788-6219 p. 1 WIScheck COMPLIANCE REPORT Wisconsin Uniform Dwelling Code WIScheck Softwar~ Version 1.0 Release 3 Permit # Checked by/Date TITLE: 2120 SF TWO-STORY WI 320 SF ADD-ON COUNTY: Winnebaga HEATING TYPE: Non-Electric DATE: 5-7-2002 PROJECT INFORMATION: 1855 HICKORY LANE COMPANY INFORMATION: CREATIVE HOMES BY RANDY STILLS NOTES: JLM (FREEDOM LUMBER) UDe COMPLIANCE: Passes Code-Allowed UA = 701 Your Home = 696 0.7% Be~ter Than Code Area or Cavity Cont. Glazing/Door Perimeter R-Value R-Value U-Value UA -----------------------------------_._----~------------------------------------- 0.340 0.320 0.340 0.240 36 114 11 93 63 2 44 9 324 CEILINGS WALLS: \~ood Frame, 16" O.c. WALLS: \~ood Frame, 16" O.c. 8SMT: Cone. 7.7' ht/6.7' bgj7.7' lnsul GLAZING: Windows or Doors, Above Grade GLAZING: Windows, Basement/foundation GLAZING: Windows or Doors, Above Grade DOORS .SLAB FLOORS: Heated, 2.0" insul. ~AC EQUIPMENT: Furnace, 90.0 AFUE 1380 1897 190 1054 185 6 130 38 320 50.0 19.0 19.0 0.0 0.0 0.0 0".0 5'.0 10.0 -------.--------.---------------------------------------------------------------- Cor4PLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet. t~~~ Wisconsin ""ifo,. Dv'elling,~Ode, ~Si9W P-~':'4,:j)> #2:-;;''''0(;>3- Date 7_7-:Z~ ~, Ha\:j 07 02 01:40p Freedom Lumber (920)788-6219 p. 1 ~...... TITLE: 2120 SF TV/a-STORY WI 320 SF ADD-ON HEATING EQUIPMENT SIZING SUMMARY General Information: Outdoor Design Temperature: Conditioned Floor Area: Average Ceiling Height: Infiltration Rate: Equipment Oversizing Factor: -15 deg 2440 ft2 8.0 ft 0.50 Normalized ACH 15.0 % Loads Summary: Conductive Losses: Infiltration Losses; Oversizing Factor Losses: 59146 Btu/ilr 14933 Btuj~r 11112 Btujh r 85191 Btujhr Total Building Heating Load: M8~ 07 02 12:41p , -, Fr@edom Lumber- p.3 U'l~nl7fl8-621.8 TITLE: 2120 SF TWO-STORY WI 320 SF ADD-ON WIScheck INSPECTION CHECKLIST Wisconsin Uniform Dwelling Code WIScheck Software Version 1.0 Release 3 DATE; 5-7-2002 Bldg. I Dept. I Use I I I r ] [ ] [ ] CEILINGS: 1. R-50 Comments/Locati on_ WALLS: 1. Wood Frame, 16" O. c., R--19 Comments/Location 2. II/ood Frame, 16" O. c., R-19 Comments/Location BASEMENT WALLS: [ ] 1. Cone. 7.7' ht!6.7' bg/7.7' insul, R-5 continuous Comments/Location WINDOWS AND GLASS DOORS: [ ] 1. U-value: 0.34 Windows must be labeled and rated in accordance with NFRC or must use default values from COMM Table 22.05-1. For windows without labeled U-values, descdbe features: # Panes__ Frame Type_ Thermal Break? [ J Yes [ ] !~o Comments/Location ________._ [ ] 2. U-value: 0.32 Windows must be labeled and rated in accordance with NFRC or must use default values from COMM Tab"le 22.05-1. For windows w'ithoutlabeled U-values, describe features: # Panes_ Fr'ame Type "' Thermal Break? [ ] Yes [ ] No Comments/Locati on ___-. _ [ J 3. U-value: 0.34 Windows must be labeled ar.d rated in accordance with NFRC or must use defaul1: values from COMM Table 22.05-1. For windows without labeled U.-values, describe features: # Panes____ Frame Type Thermal 8re~k? [ ] Yes [ ] No Comments/Locati on______ DOORS: [ ] 1. U-value: 0.24 Doors must be labeled and rated ;n accordance with NFRC or must use default values from COMM Table 22.05-2. Comments/Location SLAB-ON-GRADE FLOORS: [ ] 1. Heated, 2.0" insul.. R-10 Comments/Location Slab insulation to extend down from the top of the slab to at least 2" OR down to at least the bottom of the slab then horizontally for a total distance of 2". Ma~ 07 02 12:41p .,. ~", Freedom Lumber (920)788-6219 p.4 TITLE: 2120 SF TV/O-STORY WI 320 SF ADD-ON [ ] HVAC EQUIPMENT: 1. Furnace, 90.0 AFUE or higher Make and Model Number AIR LEAKAGE: [ ] Joints, penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be type Ie rated and installed with no penetrations or installed inside an appropriate air-tight assembly (COMM 22.32). VENTILATION: [ ] Mechanical ventilation systems must be balanced. Intake air ducts must be sized to provide a minimum of 40% of the total air that would be exhausted with all exhaust ventilation in the dwelling acting simultaneously CCOMM 23.02(3)). VAPOR RETARDER: [ ] Required on the warm-in-winter side of ail non-vented framed ceilings, walls, and floors. MATERIALS IDENTIFICATION: [ ] Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-values, and heating equipment efficiency must be clearly marked on the building plans or specifications. DUCT INSULATION: [ J Ducts in unconditioned spaces must be insulated to a minimum of R-5 (COMM 22 .17) . TEMPERATURE CONTROLS: [ ] Thermostats are requi red for each separate IWAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided CCOMM 22.15). HUMIDITY CONTROL: [ ] A humidistat is required when humidifying or dehumidifying (COMM 22.16). PIPE INSULATION: [ ] All heating pipes in unheated spaces and all cooling pipes in uncooled spaces must be insulated with a material providing a minimum thermal resistivity of R-4 (COMM 22.19). n--NOTES TO FIELD (Building Department Use Only)n-----__._nn__________n_ jY'