Job Address 1835 HICKORY LN
CITY OF OSHKOSH
PLUMBING PERMIT - APPLICATION AND RECORD
No 93783
Contractor COMPLETE PLUMBING INC
Plan
Create Date 04/01/2002
Owner JERRY H DOEMEL
Category 410 - Residential-Interior
Bathtub 1 Shower 2 EjectoJ/Grind 0 Dip Well 0 F Prep Sink 0 Gar Drain 0
- - - - -
Whirlpool 1 Floor Drain 1 Water Softner 0 Drink Ftn 0 Serv Sink 0 Soda Disp 0
Lavatory 4 Lndry Tray 1 Local Waste 0 Wait. St. 0 Shamp Sink 0 Coffee Maker 0
- - - - -
Toilet 4 Lndry Stndp 1 Clothes Wshr 1 Ice Chest 0 FlrlWst Sink 0 Int Grease Trap 0
Res. Sink 0 Disposal 1 Bidet 0 Exam Sink 0 Catch Basin 0 Ext Grease Trap 0
- - -
Bar Sink 1 Dishwasher 1 Beer Tap 0 Sculry Sink 0 Wash Ftn 0
-
Water Heater 1 Sump Pump 1 Dent. Oper. 0 Hand Sink 0 Urinal 0
- - -
Site Drain 0 Classrm Sink 0 Lab Sink 0 Plaster Sink 0 Standp Rec 0
- - -
Roof Drain 0 Breakrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker 1
Use/Nature NSFR
of Work
Size
Material
Type
Conn. Type
#
Sanitary Sewer
o
o
o
o
o
o
o
o
o
o
Storm Sewer
Water Service
o
o
o
o
o
Valuation $10,000.00
Issued By \(.'(\1\
$0.00
Permit Fees
$132.00
Plan Approval
D Permit Voided I
all work pursuant to rules governing the described construction.
Date 04/23/2002
Date 04-'d3-0-:J
Signature
Address W 7057 SHEA RD
Agent/Owner
MENASHA
WI 54952 - 0000 Telephone Number 920-380-8619
..... "f"'>
City of Oshkosh
Inspection Services Division
POBox 1130
Oshkosh, WI 54903-1130
Phone: (920) 236-5050
Fax: (920) 236-5084
~
OfHKOfH
ON THE WATER
Plumbing Permit Application
I hereby apply for a permit to do and install the following plumbing on the premises hereinafter described, the work to conform to the
Wisconsin State Plumbing Code, in the performance of which all parties hereto agree to and are bound by said statutes.
. Application(s) and fee(s) can be brought to City Hall, Room 205 or mailed to Inspection Services, PO Box 1128,
Oshkosh WI 54903-1128. Commencing work without permit(s) will result in fees being doubled or $100.00 plus the
normal permit fee, which ever is greater.
OR
If vou are a contractor participating in the Permit Fee Account Svstem and have adequate funds, check here
if vou want this processed throuf!h vour account n
Job Address i <1'5)
Owner 1;. V"\ \.V\ Y
lXISingle Family
H\'c.~~'fy LN
&." y" to 1-\
DDuplex
Value (Including labor and materia~ /6, ()CX)
CC>(/\''\f' e J ~l vi VA bl'lAj
DMulti-Family jJIRental DCommercial
Date4-);)-O J
TtVc
Dlndustrial
Number of Fixtures:
Bathtub ( Lndry Standp
Whirlpool f Disposal
Lavatory !L Dishwasher
Toilet !l.- Sump Pump
Res. Sink Ej ector/Grind
Bar Sink ,- Water Softner
Water Heater -r Local Waste
D Gas D Elect !lPwrVnt Clothes Wshr
Shower ? Bidet
Floor Drain -L Beer Tap
Lndry Tray -'- Classrm Sink
Lab Sink Surgeons Sink
Plaster Sink Breakrm Sink
Sterilizer
Electric Contractor
Contractor
I
---r-
~
~
-r
Use/Nature of Work A/SFf2-
Dent. Oper. Shamp Sink
Dip Well Flr/Wst Sink
Drink Ftn Catch Basin
Wait.St. Wash Ftn
Ice Chest Urinal
Exam Sink Gar Drain
Sculry Sink Soda Disp
Hand Sink Coffee Maker
F Prep Sink Ice Maker --I-
Serv Sink Site Drain
Int Grease Trap Roof Drain
Ext Grease Trap Standp Rec
OR
DElectric Installation Verification form attached
(If Replacement)
Size
Material
Conn. Type
Sanitary Sewer
Storm Sewer
Water Service
Type
#
3/02
AUG-26-2002 08:11A FROM:
I V i (., \1\ \. , V' "O\~. ,
",
TO: 19202365084
V"'ll.;,,'" ,t....' -. ~"".r~" 101- rVIl;1J'
V~ \J "5 'I $3 rS fI ,"c.. t:..e \I \)
WATER CALCULATION WORKSHEn
p: 1/1
.,
, InfonDatioc needed for water serviu sizing
1. go,,/ Demand of'buildint in plloDs per inin\ItC. 31 wt; (()
)
2. 1~'1
:S'
3,
4. ~
Low pnwun: lit main ill S'lrcet (or II cxtemIl pressure tank).
Difference In elevation ttom main to meter (or mern.. Jft$SW'C QrIk to buildina control ~.Ivc),
Size: of water mc:ler (if applicabl:).
,.~ Developed len!lh ft'om main to lIleter (or ectemlll pressUl'e'faJ\k to builcllng control valve).
Your must first find tbe a'\'ailable pressure after tbe "'ater meter (er aJ. b\lildinr contrOl valve).
To obtain this prenun:. you must:.
?S~ ,O~
6, I Find prcuwc Iou QUC to ftiction in ~ -inch diameter walel" scrvili~.
'.J ,'30~ Find pm$Urc loss dlle to cl~alion. mllin to meter (or Clttem41 pressure tank \0 building cantTOl valve).
Multiply wim clifTcn:nc:c in ,Icvation ~. .434 psi/ft.
8. 5 Find pressure loss due 10 meter (&om manufacturer or AWWA).
9. '16., i'1 Subll'llc:t the: ID5I due: to fri=(ln (Step 6). 1055 due to elevation (step 7), and Iou due to merer (stcp 8) lTom the
low main prcssure (Ot 10\\1 prcIsure: at clU&rJIal pressu~ Wlk (StCp ::). This calculation is the available
pressure after rhe water metA!r (or at the building col'llrol valve). This lIJ1$wcr is entered in line B below.
Information needed fot water distribution sizing
J
Using the followinl (ormuIL fiucl the pRSsurc available ror uniform loss (psi/I 00 reet of pipe).
B . (C .!> - J)
^ - F X 100
WHE1U.:
..~.
"".S;:lU.l Pressure available for uniiorm loss (psl/l00 feet of pipe).
B.!lQ.i Available prtSSUI'e after water meter (at the: building control valve 01' low pn::QImI It incernal pressure rank)
(see $tCp 9 above).
C. 2-~ Prl:sSUl't 1leCd=ct It conUQl1inS iixwtc.
D.~ J)iffc:tmee in elevation bClWCeI1 wat!;f mew (ix.ilciinS (:OmrOI valve or internal pressure WI") and controlling
fixtw'C in feet I S x .434 pili/I\.
A ,e>{:.,
E. --1.L..- ~ loss due to Wltel' sofiefters. wacet autmell.t devices. instaconeou$ water beaten and oackftow
pnt~nt&l'S which &crve 11\. controUins filn~rc. Convcmion.l water hc:ar&rs u$llally do nOt have a pressure
loss.
F. ~ Ot1'c1~ leap from wau:r meter (building comrol valve or int.emal plUsure tank) to Controlling lill;tUl'C in
feet a2: x 1.$. .
With presSUl'C available for uniform loss, SO to .pplicable cable (or dislriblltion sizins.
J
/.:<j
l J
WATER DISTRIBUTION DAT ASHEET
,'"
Date: August 26, 2002
)
Name: COMPLETE PLBG
Project: NSFR
Street:
Street: 1835 HICKORY LN
City:
City:
1. 20.8 Gallon per minute buiding demand, predominatly Flush Tank.
2. 54.0 Low pressure at the Main in Street.
3. .0 Lb loss from a.O ft difference in elevation from Main in Street to the Water Meter.
4a.~ Lb loss from a 15.0 ft I" Copper Tube Type K ASTM B88 water service from tj1e Main in Street to the curb stop.
Pressure loss detemined using a C value of 130, inside diameter of .995 and a velocity of 8.6 ft per sec.
4b.~ Lblossfroma84.0ft 11/4" PETubingCTS ASTM2737 AWWAC901 water service from the curb stop to the Water Meter.
Pressure loss detemined using a C value of 150, inside diameter of 1.060 and a velocity of 7.6 ft per sec.
5. 6.5 Lb loss from a 3/4in Meter
6. 37.7 Lbs of pressure available at the Water Meter. This value is entered in (B) below.
The (A) value listed below is determined by using the following formula, then rounding the result up.
A = B-(C+D+E) x 100
F
')
A. ------H Pressure available for uniform loss (psi/lOO feet of pipe).
B. ----.l1.!J... Lbs of pressure available at the Water Meter.
C. ~ Pressure needed at the controlling fixture. SHOWER VALVE-MASTER BA THRM
D. ~ Lb loss resulting from a 15.0 ft difference in elevation from the Water Meter to the controlling fixture.
E. .0 Lb pressure loss due to a W1R SFNR serving the controlling fixture.
F. 48.0 Ft Developed length from the 32.0 ft actual length of piping from the Water Meter to the controlling fixture.
Maximun Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 21/2 3 4
Actual I. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value ofC 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835
Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835
~
/
Date: August 26, 2002
tfJ-sr-
-~o" ~
J. f:J
1 V ,t
Fixture Listing
Ai
o
. J
Name: COMPLETE PLBG
Project: NSFR
Street:
Street: 1835 HICKORY LN
City:
City:
Non Public Use Fixtures
7?-
II,S-
~
;;-0, 5'
Hot
Cold
Total
1 Automatic Clothes Washer 1.00 1.00 1.50
1 Bar Sink .50 .50 1.00
2 Bathtub, with or without shower head 3.00 3.00 4.00
1 Dishwashing Machine 1.00 .00 1.00
2 Hose Bib, 1/2" diameter .00 6.00 6.00
1 Kitchen Sink 1.00 1.00 1.50
1 Laundry Tray, 1 or 2 compartment 1.00 1.00 1.50
4 Lavatory 2.00 2.00 4.00
2 Shower, per head 2.00 2.00 3.00
4 Water Closet, gravity type flush tank .00 8.00 8.00
Public Use Fixtures
Hot Cold Total
.00 I .50 I .50
.~
j
Q Ice Maker
Total Water Supply Fixture Units
11.50
25.00
32.00
20.8 Gallon per minute demand ofthe building. Predominatly Flush Tank
23.3 Pressure available for uniform loss. For the table use - 24.0
Maximun Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 21/2 3 4
Actual L D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value ofC 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303