HomeMy WebLinkAbout12900 (7/18/07)-Building permit (roof)
~
e
OSHKOSH
ON THE WATER
Issue Date 7/18/2007
Address 1130 N WESTFI ELD ST
INSPECTION SERVICES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance Date 8/17/2007 IMMEDIATELY
Compliance No
Sent to
~ Owner
Name
EVERGREEN MANOR INC
Address
1130 N WESTFIELD ST
City
OSHKOSH
State Zip Code
WI 54902 -3217
Introduction
U Required for Occupancy Occupancy Commercial
Reroofing has commenced prior to securing the required Building Permit. The required information shall be provided for review
~nd acceptance to determine compliance with applicable codes prior to permit issuance.
Item # Code 7-8 Compliance No
Description Reroofing has commenced prior to securing the required Building Permit.
Compliance Date 08/17/2007 IMMEDIATELY
07/18/2007
Last
Updated
Item # 2 Code Comm 62.2603.4 Compliance No Compliance Date 08/17/2007 IMMEDIATELY
Description [Provide information demonstrating the foam insulation is separated with a thermal barrier as required by 62.2603.4 or is part of a Tested/Listed
Listed Roofing system as described/required by Comm 62.2603.4.1.5. See enclosed code sections for further information.
07/18/2007
Last
Updated
12900
Page 1 of 2
e
OSHKOSH
ON THE WATER
Issue Date 7/18/2007
Address 1130 N WESTFIELD ST
INSPECTION SERVICES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance Date 8/17/2007 IMMEDIATELY
Compliance No
Sent to
~ Owner
Name
I EVERGREEN MANOR INC
Address
1130 N WESTFIELD ST
City
OSHKOSH
State Zip Code
WI 54902 -3217
Introduction
U Required for Occupancy Occupancy Commercial
Reroofing has commenced prior to securing the required Building Permit. The required information shall be provided for review
~nd acceptance to determine compliance with applicable codes prior to permit issuance.
Item # 3 Code Comm 62.1605 Compliance No Compliance Date 08/17/2007 IMMEDIATELY
Description Provide information demonstrating the weight of the roofing materials in place do not exceed the capacity of the building design. (what was the
weight of the original roof installed and what is the weight of the materials that are in place presently?)
07/18/2007
Last
Updated
Summary Compliance shall be provided by the date indicated to avoid additional enforcement action.
Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment
and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 8/17/2007
Office hours for obtaining permits are Monday through Friday 7:30-8:30 a.m. and 12:30-1 :30 p.m. or by appointment. To schedule
inspections please call the Inspection Request line at 236-5128 noting the address, permit number (when applicable), and the
nature of what needs to be inspected.
Signature Date
Inspected by: Allyn Dannhoff 236-5045 adannhoff@cLoshkosh.wLus
I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes.
Print Name Company
Signature Date
Also Sent to: ~ Bldg DAN V BINDER CONSTRUCTION 1224 W SOUTH PARK AVE OSHKOSH WI 54902 -0
---
U Elec ---
U HVAC ---
U Plbg ---
U Designer ---
~ Other HILL TOP ROOFING 5276 COUNTY RD II LARSEN WI 54947 -8732
---
U Inspector
12900
Page 2 of2
..,'."
CHAP"rER26
. .:..:.",:..::>::,<:>,'<.
. ....;,,~,',
"::f~t~~~;~l.~;1~;:_.~: :'
SECTION 260f
GENERAL
2601.1 Scope. Theseprovisi611s shall govern the maferi'als, de-
sign, application, construction and installation oHoarn phl.stic;
foam plastic insulation, plastic veneer, interior plastic finish .
and trim, and light-transmhtingplastics. See Chapter 14 for re~
quirements for exterior wall finish and trim.
SECTION 2602
DEFINITIONS
2602.1 General. The following words and terms shall, for the
purposes of this chapter and as used elsewhere in this code,
have the meanings shown herein.
FOAM PLASTIC INSULAnON. A plastic that is intention-
ally expanded by the use ofa foaming agent to produce a re-
duced-density plastic containing voids con~isting of open or
closed cells distributed throughout the plastic for thermi;ll insu-
lating or acoustical purposes and that has a density less than 20
pounds per cubic foot (~20 kg/m3). -
LIGHT-DIFFUSING SYSTEM. Construction consisting in
whole or in part of lenses, panels, grids or baffles made with
light-transmitting plastics positioned below independently
mounted electrical light sources, skylights or light-transmitting
plastic roof panels. Lenses, panels, grids and baffles that are
part of an electrical fixture shall not be ~on~idered asa light -dif-
fusing system.
LlGHT- TRANSMITTING PLASTIC . ROOF PANELS.
Structural plastic panels other than skylights that are fa,stened
to structural members, or panels or sheathing and that are used
as light-transmitting media inthe plane of the roof.
LlGHT- TRANSMITTING PLASTIC WALL PANELS.
Plastic materials that are fastened to structural members, or to
structural panels or sheathing, and that are used as light-trans-
mitting media in exterior walls.
PLASTIC, APPROVED. Any thermoplastic, therinosetting
or reinforced thermosetting plastic material that conforms to '
combustibility classificationsspecifredin the' section applica-
. ble to the application and plastic type. .
PLASTIC GLAZING. Plastic materials that are glazecl orset
in frame or sash and not held by mechanicalfasteners that pass
through the glazing material.
REINFORCED PLASTIC, GLASS FffiER. Plastic rein-
forced with glass fiber having not less than 20 percent of glass
fibers by weight. .
. THERMOPLASnC~TERIAL.A-p~astiQ mate~iaiihat is ._"
capable of being repeatedly softened by increa~e .of ,tem.pyJ:a-
ture and hardened by decrease of temperature. .
THERMOSETTING MATERIAL. A plastic material that is
capable of being changed into a substantially nonreformable
product when cured.
2002 WISCONSIN ENROLLED COMMERCIAL BUILDING CODE
SECTION 2603
FOAM PLASTIC'INSULATION
2603.1 General. The provisions of this section shall govem the
requirements and uses of foam plastic insulation in buildings
and structures. ,.
2603.2 Labeling and identification. Packages and containers
of foam plastic insulation and foam plastic insulation compo-
nents delivered to the job site shall bear the label of an approved
agency showing the manufacturer's name, the product-listing,
, product identification and informationsufficientto determine
that th d use will comply with the code requirements.
rface-buming characteristics. Unless otherwise
dicated in this section, foam plastic insulation and foam plas-
tic cores of manufactured assYIllbliy~snall h,nTe<tflame spread
index ofnotmorethan75 and a smoke-developed index of not
more than 450 where tested in the maximum thickness in-
tended for use in accordance with ASTM E 84. Loose-fill-type
foam plastic insulation' shall be tested as board stock for the
flame spread index and smoke-developed index.
Exceptions:
1. Smoke-developed index for interior trim as provided
for in Section 2604.2.
2. In cold storage buildings, ice plants, food plants, food
processing rooms and similar areas, foam. plastic in-
sulation where tested in a thickness of 4 iIlches (102
mm) shall be permitted in a thickness up to 10 inches
(254 mm) where the building is equipped throughout
with an automatic fire sprinkler system in accordance
with Section 903.3.1.1. The approved automatic
sprinkler system shall be provided in both the room
and that part of the building in which the room is h
cated.
.3. Foam plastic insulation that isa part of a Class A, B or
C roof-covering assembly' provided the assembly
with the foam plastic insulation satisfactorily passes
FM 4450 or UL 1256. The smoke-developed index
shall not be limited for roof applications. .
4. Foam plastic insulation greater than 4 inches in thick-'
ness shall have a maximum flame spread index of 75
and a smoke-developed indexof 450 where tested ata
minimum thickness of 4 inches, provided the end use
is approved in accordance with Section 2903.7 using
the thickness and density intended for use.
2603.4 Therm~llmrri,~l'" E"c:ept as provided for in Sections
2603.4. band 2603.7, foam plastic shall be separated frOluthe
interior of a building by an approved thermal barrier of OS inch
.... (12.7 mm) gypsum wallboard or equivalen,ttherill31 barrierma~
terial that will limit the average temperature rise of the unex~
. posed surface to not more than 2500F (120oC) after 15 minutes
of fire exposure, complying with the standard time-tempera-
ture curve of ASTM E 119. The thermal barrier shall be in-
stalled in such a manner that it will remain in place for 15
B-519
2603.4.1 - 2603.4.1.10
minutes based on FM 4880, UL lO400rUL 1715. Combustible
concealedspacesshall comply with Section 716.
;"'. ~.,~, ",.! ~"ff~N~;1ii:O:ililUi_
rier specified in Section 2603.4 is not required under the
conditions set forth in Sections 2603.4.1.1 through
2603.4.1.12.
2603.4.1.1 Masonry or concrete construction. In a ma-
sonry or concrete wall, floor or roof system where the
foam plastic insulation is covered on each face by a mini-
mUIl) of I-inch (25.4 mm) thickness of masonry or con-
crete.
~ttllllls. Foam plastic in-
stalled in a maximum thickness of 10 inches (254 mm) in
cooler and freezer walls shall:
1. Have a flame spread index of 25 or less and a
smoke-developed index of not more than 450,
where tested in a minimum 4- inch (102 mm) thick-
ness.
2. Have flash ignition and self-ignition temperatures
of not less than 6000P and 8000P (3160C and
4270C), respectively.
3. Have a covering of not less than 0.032-inch (0.8
mm) aluminum or corrosion-resistant steel having
a base metal thickness not less than 0.0160 inch
(004 mm) at any point.
4. Be protected by an automatic sprinkler system.
Where the cooler or freezer is within a building,
both the cooler or freezer and that part of the build-
ing in which it is located shall be sprinklered.
2603.4.1.3 Walk-in coolers. In unsprinklered buildings,
foam plastic having a thickness that does not exceed 4
inches (102 mm) and a maximum flame spread of 75 is
permitted in walk-in coolers or freezer units where the
aggregate floor area does not exceed 400 square feet (37
m2) and the foam plastic is covered by a metal facing not
less than 0.032-inch-thick (0.81 mm) aluminum or cor-
rosion-resistant steel having a minimum base metal
thickness of 0.016 inch (0.41 mm). A thickness of up to
10 inches (254 mm) is permitted where protected by a
thermal barrier.
2603.4.1.4 Exterior walIs-one story buildings. Por
one-story buildings, foam plastic having a flame spread
index of 25 or less, and a smoke-developed index of not
more than 450, shall be permitted without thermal barri-
ers in or on exterior walls in a thickness not more than 4
inches (102 mm) where the foam plastic is covered by a
thickness of not less than 0.032-inch-thick (0.81 mm),
aluminum or corrosion-resistant steel having a base
metal thickness of 0.0160 inch (0041 mm) and the build-
ing is equipped throughout with an automatic sprinkler
in accordance with Section 903.3.1.1.
oam plastic insulation under a roof
assembly or rering that is installed in accordance
with the code and the manufacturer's installation instruc-
tions shall be separated from the interior of the building
by wood structural panel sheathing not less than 0.47
inch (11.9 mm) in thickness bonded with exterior glue,
B-520
( .
PLASTIC
with edges supported 'by blocking,tbngue-aild-'gr60ve
joints or other approved type ofede sli ort '. an
equivalent material.
2603.4.1.6 Attics and crawl spaces. Within an attic or
crawl space where entry is niadeonly for service ofutilF
ties, foam plastic insulation shall be protected against ig-
nition by 1.5-inch-thick (38 mm) mineral. fiber
insulation, 0.25-inch-thick (6Amm) wopd structwal
panel, particleboard or hardboard, O.375~inch (9.5 mm)
gypsum wallboard, corrosion-resistant steel having a
base metal thickness of 0.0 16 inch .(004 mm), or other ap-
proved material installed in such a manner that the foam
plastic insulation is not exposed. The protective covering
shall be consistent with the requirements for the type of
construction.
2603.4.1.7 Doors not required to have a tire protection
rating. Where pivoted or side-hinged doors are permit-
ted without a fire protection rating, foam plastic insula-
tion, having aflame spread inqex of 75 or less and a
smoke-developed index of not more than 450, shall be
permitted as a core material where the door facing is of
metal having a minimum thickness of 0.032-inch (0.8
mm) aluminum or steel having a base metal thickness of
not less than 0.016 inch (004 mm) at any point.
2603.4.1.8 Exterior doors in bujldings of Groups R-2
or R-3. In occupancies classified as Groups R-2 or R-3 as
applicable in Section 101.2, foam-filled exterior en-
trance doors to individual dwelling units that do not re-
quire a fire-resistance rating shall be faced with wood or
other approved materials.
2603.4.1.9 Garage doors. Where garage doors are per-
mitted without a fire resistance rating and foam plastic is .
used as a core material, the door facing shall be metal
having a minimum thickness ofO.032~inch(0.8 niril) alu-
minum or O.OlO-inch (0.25 mm) steelorthefacing shall
be minimum 0.125-inch-thick (3.2 mm) \\lood., Garage
doors having facings other than those desCJ.ibed. above
shall be tested in accordance with, andmeet th,ea9cep~
tance criteria of, ANSI/DASMA 107,
Exception: Garage doors using foam plastic insula-
tion complying with Section 2603.3 in detached. and
attached garages associated with one- and two-family
dwellings need not be provided with a thermal barrier.
2603.4.1.10 Siding backer board. P~am pl~stiCins~la:'
tion of not more than 2,000 Btu/sq.ft (21~7 MJ/m2) as de-
termined by NFPA 259 shall be petniittedasa:siding
backer board with a maximum thickness of 0.5 inch (12.7
mm), provided it is separated from the interior of the
building by not less than 2 inches (51 mm) of mineral fi-
ber insulation or equivalent or where applied as insula-
tion with residing over existing wall construction.
2002 WISCONSIN ENROLLED COMMERCIAL BUILDING CODE