Loading...
HomeMy WebLinkAbout12897 (7/18/07)-Electrical '~G OSHKOSH ON THE WATER Issue Date 7/18/2007 Address Sent to Introduction INSPECTION SERVICES DIVISION ROOM 205 DEPARTMENT OF COMMUNITY DEVELOPMENT CORRECTION NOTICE CITY OF OSHKOSH 215 CHURCH AVE PO Box 1130 OSHKOSH WI 54903-1130 Compliance Date 8/17/2007 Compliance No 913 CHERRY ST Name 1 PINE APARTMENTS I LLC Address 3389 COUNTY ROAD A State Zip Code WI 54901 -1414 City OSHKOSH ~ Owner U Required for Occupancy Occupancy Following a tenant complaint an inspection was performed at the above-mentioned address. The below-listed violation(s) need o be corrected. Item # Code NEC 406.3(B) Compliance No Compliance Date 08/17/2007 Description Receptacles and cord connectors that have grounding contacts shall have those contacts effectively grounded. 3 prong receptacles cannot be connected to a 2 wire circuit. 07/18/2007 Last Updated Item # 2 Description 07/18/2007 Last Updated Item # 3 Description 07/18/2007 Last Updated Code NEC 240.4(D) Compliance No Compliance Date 08/17/2007 IUnless specifically permitted in 240.4(E) or 240.4(G), the overcurrent protection shall not exceed 15 amperes for 14 AWG, 20 amperes for 12 iAWG, and 30 amperes for 10 AWG copper; or 15 amperes for 12 AWG and 25 amperes for 10 AWG aluminum and copper-cladaluminum bfter any correction factors for ambient temperature and number of conductors have been applied. 30 amp single pole ckt. breaker too large or tonductors in circuit. Code NEC 400.8 (1-4) Compliance No Compliance Date 08/17/2007 Flexible cords-Uses Not Permitted: (1) As a substitute for the fixed wiring of a structure (2) Where run through holes in walls, structural ceilings, suspended ceilings, dropped ceilings, or floors (3) Where run through doorways, windows, or similaropenings (4) Where attached to building surfaces. Extension cord supplying power to dryer not allowed. Item # 4 Code NEC 314.17(A) Compliance No Compliance Date 08/17/2007 Description ppenings through which conductors enter shall be effectively closed. Knockout closure missing in box above water heater. 07/18/2007 Last Updated Item # 5 Code NEC 110.22 Compliance No Compliance Date 08/17/2007 Description Each disconnecting means shall be legibly marked to indicate its purpose unless located and arranged so the purpose is evident. The marking ~hall be of sufficient durability to withstand the environment involved. Panel index not filled out. 07/18/2007 Last Updated 12897 Page 1 of 2 .tG , OSHKOSH ON THE WATER Issue Date 7/18/2007 INSPECTION SEFMct:s DIVISION ROOM 205 DEPARTMENT OF COMMUNITY DEVELOPMENT CORRECTION NOTICE CITY OF OSHKOSH 215 CHURCH AVE PO Box 1130 OSHKOSH WI 54903-1130 Compliance Date 8/17/2007 Compliance No Address 913 CHERRY ST Sent to l!'J Owner Name I PINE APARTMENTS I LLC Address 3389 COUNTY ROAD A City OSHKOSH State Zip Code WI 54901 -1414 Introduction U Required for Occupancy Occupancy Following a tenant complaint an inspection was performed at the above-mentioned address. The below-listed violation(s) need o be corrected. Item # 6 Code NEC 358.42 Compliance No Compliance Date 08/17/2001 Description Couplings and connectors used with EMT shall be made up tight. Water heater pipe-to-f1ex connection apart. 07/18/2007 Last Updated Summary Please make arrangements to have these violations corrected in the next 30 days. Feel free to contact me with any concerns or questions at 236-5274. Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 8/17/2007 Office hours for obtaining permits are Monday through Friday 7:30-8:30 a.m. and 12:30-1 :30 p.m. or by appointment. To schedule inspections please call the Inspection Request line at 236-5128 noting the address, permit number (when applicable), and the nature of what needs to be inspected. Signature Date Inspected by: Adam Krause 236-5274 akrause@ci.oshkosh.wi.us I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: U Bldg U Elec U HVAC U Plbg U Designer U Other U Inspector 12897 Page 2 of 2