Loading...
HomeMy WebLinkAboutBuilding Y-7-2026-0607 ~ .OJHKOfH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.ci.oshkosh.wi.us ON THE WATER July 13,2007 Stephen Gries Gries Architectural Group Inc 500 N Comrilercial Street Neenah; WI 54956 John Bergstrom Bergstrom Corporation 150 N Green Bay Road Neenah, WI 54956 Site: Plan Number: Y7-2026-0607 Bergstrom - Honda New & Used Car 3285 S Washburn St Oshkosh WI 54904 For: Description: Tenant space alterations / addition Object Type: Building only Class of Construction: VB -12,676 Sq Ft.; unsprinklered Occupancy: B: Business Office The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item{s) / Conditions: . IBC 906.1 /IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet. . IBC 1003.2.10 Exit signs are required to be installed per this section . IBC 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress are required to have adequate emergency lighting to meet the performance requirements of IBC 1003.2.11.3. Existing means of egress emergency lighting is permitted to be maintained in compliance with the code in effect at the time of construction. Any altered path of egress, or new path of egress, and any new emergency lighting being installed is required to comply with current code requirements. . MUN 30 This review does not include review for signage. Applications for and questions regarding signage permits should be directed to Todd Muehrer - Associate Planner (920) 236-5057. . Comm 5.34 No person may perform structural welding unless the person holds a registration issued by Department of Commerce. Provide welders registration numbers for all people doing welding on this project. l:\Tn$pedio.11s\Pbn ReVlt'\.\'\Cml1rnt:.n:iaJ Pt~U1 IZ.t'vl>:W 2Qn7\.Y'7-:::(l~_~6</'.607 3285 S \VasJlburn St T:~.ldg Oniy.doc Page 1 of2 . Comm 61.30(3) I IMC 507.2 This plan review does not include heating, ventilation, or air conditioning. HV AC plans are required to be submitted and approved prior to installation of HV AC equipment. SUBMIT: . IRC 1003.2.11 Means of egress illumination is required tobe installed per this section. All paths of egress are required to have adequate emergency lighting to meet the performance requirements of IBC 1003.2.11.3. Provide complete emergency lighting plan-showing compliance with these requirements prior to installation of emergency lighting system. . Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. Res~ ~ Building Systems Consultant (920) 236-5051 Monday- Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M. bnoe@ci.oshkosh.wi.us . .> cc; Property file Fee Required $ Fee Received $ Balance Due $ 700.00 700.00 0.00 L\Tn~pe(:l,kns\Plan ,Re'\,'ll;,"\v\Connl1en:ial P[~ln r:,f;V_~ltW 2007-\")7']-20':.6......06073::3.5 S \Vashburn S1 n.1dg Only.do{; Page 2 of2