Loading...
HomeMy WebLinkAbout2007-Building Y5-2015-0607 ~ OJHKOfH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.ci.oshkosh.wLus ON THE WATER July 9,2007 Daniel Meissner Daniel J. Messner, AlA, LLC 1230 E Calumet Street Appleton, WI 54913 Thomas Mc Crory Mc Crory Properties, LLC 5062 Malibu Cove Oshkosh, WI 54904 Site: Plan Number: Y5-2015-0607 Furniture & Appliance Mart 1205 S Washburn St Oshkosh WI 54904 For: Description: Tenant space alteratious Object Type: Building only Class of Construction: lIB - 19988 Sq Ft.; sprinklered Occupancy: M: Mercantile 1 Retail The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01(10), ,Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) 1 Conditions: . IBC 901.2 Fire protection systems shall be installed, repaired, operated and maintained in accordance with this code and the international fire code. Construction of new walls may require the addition and or relocation of sprinkler heads to maintain required coverage, and not obstruct spray patterns of fire sprinklers. Additionally, according to Oshkosh Fire Department Inspectors there are existing deficiencies in the sprinkler system that require correction . IBC 906.11 IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet. . IBC 1003.2.10 Exit signs are required to be installed per this section . IBC 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress are required to have adequate emergency lighting to meet the performance requirements of IBC 1003.2.11.3. Existing means of egress emergency lighting is permitted to be maintained in compliance with the code in effect at the time of construction. Any altered path of egress, or new path of egress, and any new emergency lighting being installed is required to comply with current code requirements. . Comm 62.1101 General Requirements. ANSI A117.1-404.2.4 Maneuvering Clearance at doors. Maneuvering clearance shall comply with Table 404.2.4.1. The door into the women's accessible toilet stall does not have the required access on the latch side. As discussed with the designer the door will be swung into the stall to provide the required maneuvering clearance. ):\Inspediuns\Plan ReVll,;W,,('nrnmen:lal Phn Revil:w ?OU7\Y5-20 15,06("7 :205 SWasilb\lnJ St Ilidg On,'y,doc Page 1 of3 · mc 2902..1 / Table 2902 Drinking water is required to be provided, no drinking fountain is shown on plans. Either a drinking fountain or a bottled water cooler is required to be provided . NEC 110.26 Spaces About Electrical Equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. Caution - depending on the electrical equipment being enclosed by walls on the North wall there may be inadequate clearance - Contact Electrical Inspector - Kevin Benner (920) 235-5046 to review and discuss this issue . Comm 61.30(3) / IMC 507.2 This plan review does not include heating, ventilation, or air conditioning. HV AC plans are required to be submitted and approved prior to installation ofHV AC equipment. . Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm 61.31(1). SUBMIT: · mc 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress through The Retail Display area are required to have adequate emergency lighting to meet the performance requirements ofIBC 1003.2.11.3. Provide complete emergency lighting plan-showing compliance with these requirements prior to installation of emergency lighting system. · mc 2902 Table 2902.1 Minimum Number of Plumbing Facilities. A minimum of one service sink is required to be provided. IMC 403.3 [Comm 64.0403 (6)] Ventilation rate. Janitor closets. A janitor closet that has only one service sink may be provided with either natural ventilation via a window or louvered opening with at least 2 square feet (0.2 m2) of area openable directly to the outside or mechanical exhaust ventilation as specified in Table 64.0403. Plans submitted do not show the required service sink included in building plans. Comm 62.2900 (2) requires a service sink to be located in ajanitors closet, and the 1M C requires ventilation of that sp(lce. Provide additional details / floor plan showing where the required servicesink will be located and how required ventilation will be provided. · Comm 61.30(3) This review does not include lighting. Comm 63.0001 Prior to installation, lighting plans and calculations shall be prepared in compliance with the code. Please submit lighting work sheets. . Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. ):"Jnsp.;:d.inns\Plan Ikvi;:w\(\,rnm.;:n:ial PLul Re-v:e'V'" 2i.ltF,Yj-2(l!5,{1607 [;':05 S Washbum Sl Bicig On.iy.do(; Page 2 of 3 Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. ~' Brian Noe Building Systems Consultant (920) 236-5051 Monday - Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1 :30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 770.00 770.00 0.00 I:\[rl$p",'liuns'.Pbn [<evi,,'w'.('orrrmen:ia[ Pian Rt."vit:w 2007',,'S.',:(\l5.n607 1205 S Washburn 51 Bidg Only.doc Page 3 00