Loading...
HomeMy WebLinkAbout0099830-BuildingOSHKOSH ON THE WATER Job Address Designer Category Type 4090 SHARRATT DR 110 - New Single Family CITY OF OSHKOSH BUILDING PERMIT -APPLICATION AND RECORD Owner SHOWCASE CUSTOM HOMES INC Contractor SHOWCASE CUSTOM HOMES INC No 0099830 Create Date 01/30/2003 Plan E1-006-0103R · Building O Sign O Canopy O Fence O Raze Zoning R-1 Class of Const: 8 Size Irrg Unfinished/Basement 480 Sq. Ft. Rooms 8 Height 21 Ft. [] Projection Finished/Living 1728 Sq. Ft. Bedrooms 4 Stories Quad-level Canopies Garage 741 Sq. Ft. Baths 2 Signs Foundation · Poured Concrete O Floating Slab (~) Pier (~ Other O Concrete Block (~ Post ~) Treated Wood Occupancy Permit Required Flood Plain No Height Permit Not Required Park Dedication Required # Dwelling Units 1 # Structures 1 Use/Nature NSFR/ New single family quad level with 3 car attached garage 11' x 12' patio. Driveway shall be a maimum of 24' wide at the front of Work property line. HVAC Contractor Electric Contractor Fees: Valuati~ Issued By: BREWER HEATING SCHOMMER ELECTRICAL CON Plumbing Contractor P&S PLUMBING $95,100.00 Plan Approval $75.00 Permit Fee Paid [] Permit Voided $368.00 Park Dedication $100.00 Date 02/17/2003 Final/O.P. 00/00/0000 In the perf~m~[nce of~[~is work I agree to perform all work pursuant to rules governing the described construction. SI nature k/-¢:;'?'"¢~ '//'/' ~ /' 'g ~l, ..~.~>.. ,~_,?_~?. (L-/'~j~7~r~:;~¢-~,.. Date I~,,,_ Agent/Owner Address 2755ALGOMA BLVD OSHKOSH WI 54901 - 0718 Telephone Number 235-5610/c-379-9046 OSHKOSH GRADE STAKE FORM ON THE WATER Grade Stake Number 6891 Name SHOWCASE CUSTOM HOMES INC Address 4090 SHARP, ATT DR Create Date 01/30/2003 Lot 33 Block Ward Subdivision NORTH PARK ESTATES Zone Street Number Lot Dimensions ~ Sidewalk Existing Building Grade Elevation Stakes Set At Site 02/03/2003 Set By D.W.G. BK - 586, P - 72 Department of Public Works I, the undersigned, owner or agent of the above described property agree~o hav~th? grade established before excavation WisconSin Department of Industry, Labor and Human Relations Safety and Buildings Division P.O. Box 2509 Madison, WI 53701-2509 Wisconsin Statues 101.63, 101.73 [] Constr Owner's Name SHOWCASE CUSTOM HOMES IN(: Contractor: L~ conE~ Elec'E~] SHOWCASE CUSTOM HOMES INC Contractor: SCHOMMER ELECTRICAL CON Contractor: BREWER HEATING Contractor: L_.J Con P&S PLUMBING Lot Area Building Address 4090 SHARRATT DR Zoning District(s) Permit No. WISCONSIN UNIFORM BUILDING PERMIT APPLICATION ~hN~aApplication No. [] HVAC [] Elec [] Plbg [] Erosion [] Other: Mailing Address 2755 ALGOMA BLVD Oshkosh WI 54901 - 0000 Mailing Address 2755 ALGOMA BLVD OSHKOSH WI 54901 - 718 Mailing Address N 164 TWO MILE ROAD APPLETON WI 54914 - 9121 Mailing Address N8804 N DOUGLAS STREET RIPON WI 54971 - 0 Mailing Address BOX 2153 APPLETON WI 54913 - 0 Telephone No. Telephone No. 235-5610/c-379 Telephone No. (920) 731-2299 Telephone No. (920)748-6494 Telephone No. 734-3912 1/4, 1/4,Section ,T N,R E(or)W Subdivision Name NORTH PARK ESTATES Lot No. 33 Block No. Front Rear Left Right New [] Repair [] Alteration [] Raze [] Addition [] Move [] Other: Unfinished Basement 480 Sq. ft. Living Area 1728 Sq. ft. Garage 741 Sq. ff. Single Family Two Family Garage [] Other (pdnt): [] Site Constructed [] Manufactured Entrance Panel Size: 200 am Service: [] Overhead [] Underground [] Masonry ~ [] Treated Wood ~:§~{~r ~ [] Other [] 2-Story [] Seasonal [] Other [] Permanent Quad-level [] Other [] Plus Basement Forced Air Furnace [] Radiant Baseboard or Panel [] Heat Pump [] Boiler ~[] Central Air Conditioning Sewer [] Municipal [] Septic Permit No. [] Municipal Utility [] Private On-Site Well Fuel Space Htg Water Htg * L_J Dwelling unit will have 3 kilowatt or more installed electric space heating equip. Infiltration control option is: [] Full sealing of joints. [] Blower door test. [] Exterior air infiltration barrier. Envelope 23804 BTU/HR Infiltration 12901 BTU/HR $111,000.00 The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this )ermit, understands that the issuance of the permit creates no legal liability,~xpre~,s or jc~plied, on the Department or municipality; and certifies that all the above information is accurate. APPLICANT'S SIGNATURE~ / ~,~ ~/ ,,~¢/~.¢--A__ DATE SIGNED ~-/~%,/~ ........... ~'T~s permit is issued pursuant to the following conditions. Failure to comply may result in suspension or APPROVALL;UNUI/IUI~I,,~,' revocation of this permit or other penalty SEE "STANDARD CONDITIONS OF APPROVAL" SHEET []Town [] Village [] City [] County L_J State of: Municipality Number of Dwelling Location: City Of Oshkosh 7 0 - 2 6 6 Plan Review $75.00 Construction HVAC Name JOHN ZARATE Inspection Electrical Wis. Permit Seal $30.00 [] Plumbing Date 1/30/03 Other [] Erosion Total $105.00 --] 288709 Cert. No. 70330 SBD-5823 (R. 07/92) OSHKOSH ON THE WATER Job Address Name Address Subdivision Owner's Signature Inspector's Signature PARKLAND DEDICATION FEE COLLECTION RECORD 4090 SHARRATT DR SHOWCASE CUSTOM HOMES INC 2755 ALGOMA BLVD NORTH PARK ESTATES Building Permit Number 0099830 Number of Dwelling Units 1 Fee Required $100.00 Date 02/17/2003 Oshkosh WI 54901 Lot 33 Number of Structures Fee Paid Date Date FARMSTEAD I 0 , 30'-0' , 65'-0' '~ 25'-0' > m oa ~ 35.3' m _--J i 26' DRIVEWAY AND' -._ HOUS~ 4' GRAVEL ACCESS DRIVE i 124' UAX ~ LOT LiNE ~ ~~ i 25.5''''''''''~, : 23.5' PLAN# QUAD- 1728-.301 i~AY OR O~ ~ I~ ~Y LOC~ ~. eI~CTC~ FOR ,~J~' GUESTION5. ** Z:'~z'~l ~b.,l~ ZfO~© SHARRETT DRIVE ~LOT ~l.~ ~'-.,~' I~ ']:~ 1_~.o~I SHOWCASE O/HKO/H City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 Office 920-236-5050 Fax 920-236-5084 PLAN REVIEW Project Address:4090 SHARRATT DR Submitted By:SHOWCASE CUSTOM HOMES Plan Number:E 1-006-0103R Reviewed By: JZ Phone: 920-236-5119 Date Reviewed: 1/31/2003 Phone Number: 235-5610 [--] Mailed [--] Faxed [5~ Delivered Date: Result of Plan Review: [5~ Conditionally Approved [~] Withheld Pending Approval of Additional Information [~] Not-Approved, Plans Returned for Revisions Conditions Noted on Plan Review 1) All required smoke detectors shall be indicated on the floor plan for any future plans. 2) Fire seperation between the garage and living space shall be indicated on the floor plan for any future plans. 3) The proposed patio shall be installed prior to occupancy or a code compliant exit installed for the rear patio doors. P roj ecl read o o All habitable ~rooms must be provided with 8% l°Cated on the Sec°nd floor'or below gr°und level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows are als° required t° hage Wind°w Well areas in accOrdance with ILHR 21~03. Garage spaces shall be g unii in accordanCe wi~ ILHR 21.08. The door and frameassembly between the dwelling unit and an attached garage shall be labeled bY an' ~dePendent t~sting agenCY aS haVing a minimum fire-resistive rating of 20 minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so that the gap is no more than a dimes thickness (1/20-inch) and backed by solid wood or drywall with the joints staggered. All penetrations in inspection. This includes holes in the top and bottom plates, gaps around heating ducts, and holes in the HydromaSsage tubs are required to have an access panel to motor. The access panel must be accessible WSthout removing the finish of the house. All 0verfrming must be designed by the truss manufacturer, according to standards set by the truss plate institute, or strUctural cai6ulations must be provided priOr to the rough building inspection. Truss plans must be submitted and approved Prior to framing the roof. Truss plans including the tress layout must be provided on site at the rough building insPection. In addition to the truss plans, microlam calculations must be provided on site at the rough building inspection for all microlams with point loads on them. CalCUlatiOns must be provided for all cantilevered floors with point loads. Floor trusses and TJi'S.must be:designed for the cantilevered areas 10.' 11. The property owner and applicant is responsible for compliance with ILHR 21.125 (Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20~ width. Erosion control measures must be maintained until the lawn is established. All storm sewer inlets must be protected with apprOved erosion control devices. Tracking (i.e. sediment) must be removed from the street at the end of each workday. Repair any siltation or erosion damage to adjoining surfaces and drainageways resulting from land development or disturbing activities. 12. The building placard must be posted on site at all times. Once the rough framing is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work oiders will be posted. Additional placards can be obtained through our department if the cards are misplaced. 13. All mechanicals, must be roughed in prior to requesting the rough building inspection. If on the insPection ~'~' ~n;chanicals are not roughed in, the inspection will fail and a $100 re-inspection fee will be charged. 14. AttaChed is a copy of the final inspection checklist. At the final inspection all items on this list must be completed to avoid the $100 re-inspection fee per inspection. 15. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only allowed to be placed in the center of the garage floor and a minimum of a 3' pathway must be provided around the walls of the garage. At the final inspection no furniture or personal belongings are allowed in the house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in place due to the electrical inspector needing to look at the power serving the appliances. A 6' stepladder must be on site at the final inspection to provide access to the attic. 16. The building placard must remain on the patio door or on a kitchen window until occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the backside. If occupancy occurs prior to the inspections being approved daily citations will be issued with no further notice being given. 17. All site grading must be done in accordance with the approved drainage plan on file in the / public works office, 3rd floor. / \