Loading...
HomeMy WebLinkAbout0125397-Plumbing (interior) o OSHKOSH ON THE WATER Job Address 2319 HICKORY LN CITY OF OSHKOSH No 125397 PLUMBING PERMIT - APPLICATION AND RECORD Shower Floor Drain Owner JAMES R DITTMER Create Date 06/18/2007 Category 410 - Residential-I nterior Plan Water Softner Wait. St. Shamp Sink Coffee Maker Local Waste Ice Chest Flr/Wst Sink Int Grease Trap Clothes Wshr Exam Sink Catch Basin Ext Grease Trap Bidet Sculry Sink Wash Ftn RPZ Valve Beer Tap Hand Sink Urinal Eye Wash Statn Lab Sink Plaster Sink Standp Rec Wtr Sewer Mtrs Sterilizer Surgeons Sink Ice Maker Deduct Meters Dip Well F Prep Sink Gar Drain Wtr Usage Mtrs Drink Ftn Serv Sink Soda Disp Contractor L.C. PLUMBING INC. Bathtub Whirlpool Lavatory Toilet Res. Sink Bar Sink Water Heater Site Drain Roof Drain Misc. Fixtures Use/Nature INSFR/ Prefab home interior plumbing, with a power vent water heater for basement fixtures and stack connections. "Water calculation is an of Work !;'A" of 1 0.'* Check #6445 Valuation Issued By Lndry Tray Disposal Dishwasher Sump Pump Classrm Sink Breakrm Sink Ejector/Grind 3 1 silcock, 2 stacks Size Material Type # Conn. Type Sanitary Sewer Storm Sewer Water Service Parcelld # 1518678500 $5,000.00$-"'0" Ap",ovo' Crrn $0.00 $63.00 0 Permit Voided I Permit Fees Date 06/19/2007 In the performance of this work, I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Agent/Owner FREEMONT WI 54940 - 8529 Telephone Number 1-920-867-5051 Address N7012 ST RD 49 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (Le. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. Ma.y.29. 200i 9:21AM City ~)f Oshkosh lllspcc(ion Services Division f' 0 Box 1130 O~hkosh, WI 5490H 130 Phone; (920) 236-5050 Fax: (920) 236.5084 inspect ion serVices No. 28?0 r' . Plumbing Permit Application All information after bold clltegorles shall be provided. Incomplete appliclItions will not be pf'Oce~sed. Disposal Dis\lwaS!l(:[ Sml1p Pump I:Ij"ctiJrlGripd Wst~r l;(1rrner Lm;lll Wasle Cl(flhes Wshr Hidel ........1.....".. Application(s) and feces) can br: brought to City HaU, Room 205 or mailed to Inspcc.tion Service.:>, PO Box 1128. Oshkosh WI 54903Ql1:28. Commencing work without permit(s) will result in fees being dDubled or $100.00 plus the normal permit fcc, which ever is greater. OR o Che,k this box to process this permit through your account. (This is only available for contractors v;,11o part.iclpal.c in the Permit Fee Acccn.:mt System. A $25 surcharge will be deducted frum your account jf tllel'e al'e no f\lnds available to process the penuit.) th 'clco ~L Lo-~ VALUE (Illc,llldlng[al}(.ll'~n(l m:lterials) $ .5000 I .J DATE trl -OJ c JOBADDRESS ?-~.1 q pf'i-+~'- OWNER_ t10nfJPStfM fur \detS PLUMBING CONTRACTOR L C PILJmbi/~0 /XrJiJ-/ ELECTRV\L CONTRACTOR (I'he pcnni( will not be pr(lc.cs~ed withuu! thi~ inin.) '" ~Single Fa~llHY ODupl?x OMuHi-F~lmiJy ORental DCommerciul Number of Fixtures: --..L.- Bathtlli;l Whirlponl L~val(lry Toilel Res. Sink Dat'Sink Water IIeater --l- G OilS !J r-:lc~t liI:I pwrVnt ~ ~ ShOWN fl00r Drain Lndr)' Tray Lab Sink --l- Plast<,:.r Sillk St~riliz(:r Misc. Rter Tap Cl;!s~m) SinK Surgeons :;ink Hreakrm Sink Dip\Vd! Host: Bibs I fixturGS ;2 - f)6U~lv )~~ Use/ Nature Of\VOrk-f2r-ef-Q.JJ---110vn? Olndustrial Drilll' Frn WaJt.St. Ice Ch~st Exam Sink Sculry Sink Hand Sink l' Prep Sink Serv Sink Int Grea.~e Tmp ~xl Grease Trup R,l'./,. Valve Shamp Sink F'lr/W~t Sink Calch R~sln Wash \-"tn Urinal Gat Dmin Soda Disp Coffee Maker CQlllm. Tee Milker Site Drain Roof Dtajf] :;tandp Rec r.:yc Wash Sin Wlr SeWer MIlS De(!l.lcl Mewrs Wtr Usage Mtm ~ X 1 yjL. ::; 0?;;>~ - Y.)BLU LOY1~-h0~ Sanimry S~w~r Storm Scwc.r I ~atet' Service Size Material .-''l'~.....-................",,~_..'.''''''- Type # Conn, Type OS/29/07 :::06/18/2007 15:40 FAX 9208673499 ~ HEMAUER 141 001 WATER CALCULATION WORKSHEET FOR )/1 n. .' >-~.) \ ,." -1..) I C/(O Y' Cl DC:~i,h J(CJ~~j~ NAMI:/A!lDRESS OF ~OJECT INFORMATION REQUIRED 'f0 CALCULATE WATER SERVICE SIZE 1. Demand of building in gallons per minute. WSFU's 2. Difference In elevation ftom main to extermal pressure tank or to building control valve. 3. Size of the water meter, (when applicable) 5/8 3/4 X 1 1.5 2 3 4 6---' 4. Developed length from main or extemel pressure tank to building control valve. 5. Low pressure at main in street or external pressure tank... 25.5 Inch Inch CALCULATE WATER SERViCe PRESSURE LOSS 6. Low pressure at main in street or external pressure tank. (value of #5 above) 7. Water service diameter Is 1.25 Material Is Pressure loss per 100 ft.. 100 psl)( 0.35 (decimal eqUivalent of service length, i.e. 65 fl "" 0.65) (Subtract line 7. From line S.) 8. Determine pressure gain or loss due to elevation. (multIply the value of #2 above by 0.434) 9. Avellable pressure after the bldg. Conrol valve. (subtract or add line 8. Enter in "6".) CALCULATE THE PRESSURE AVAILABLE FOR UNIFORM LOSS (VALUE OF "A") B. Available pressure after the building control valve. (from "9" above) C. Pressure 10S$ of water meter. (when meter Is required or installed) ($ubtract line C. From B.) D. Pressure at controUlng fixture. (controlling fixture is' master shower (subtract the value of 0.) E. Difference In elevation between the building control valve and the controlling fixture In feet 9 X 0.434 psilft. (subtract the value of E.) F. Pressure loss due to waler treatment devices, instantaneQUS water heaters and backflow preventers whloh serve the controlling flXlura. Pressure 10&$ due to (subtract the value of F) G. Developed length from building control valve to controlling fixture in feet X 58 1.5 (divide by the value of G.) Water distribution piping material Is: = (GPM) (feat) (feet) (pslg) subtotal value of "8" subtotal value of "8" value of lie" subtotal value of "0" subtotal VSlUB of "En subtotal value of "f" subtotal value of "G" subtotal 17.3 2.0 35 72.0 72.0 35.0 37.0 0.9 36.1 36.1 4.2 31.9 20,0 11.9 3.9 8.0 0.0 8.0 87.0 0.092 (multiply by 100) A. Pressure available for uniform loss Comments "A" = 100 9.2 1##/' ...,.... '. '1IIIIIIJtJLll~ ... .... ..,............................... ......~-_...............- ........... .......... ... ................. .". ,......,.. ...~..... ..........~..-:-...... ...........FI#/# we will be rllnning I" copper to f.::eu I. 1/2" sillcoclc, future bill\! . then tying into the pre.manuf~()lured h~mcs 3/~" pex which IS . lllready installed. The sillcock and l\.!IUn: balh arc the only fixtures we Ilte installing that ure not Included In the (lng(nlll consb'uotlon of the home 56D-10717.. E (RiO/OS)