Loading...
HomeMy WebLinkAbout12786-Electrical maintenance e OSHKOSH ON THE WATER Issue Date 6/14/2007 INSPECTION SERVICES DIVISION ROOM 205 DEPARTMENT OF COMMUNITY DEVELOPMENT CORRECTION NOTICE CITY OF OSHKOSH 215 CHURCH AVE PO Box 1130 OSHKOSH WI 54903-1130 Compliance Date 7/14/2007 Compliance No Address 721 VINE AVE Sent to ~ Owner Name I TITAN STUDENT HOUSING LLC Address 3200 E CANVASBACK LN City APPLETON State Zip Code WI 54913 -0000 Introduction I hile conducting a routine neighborhood inspection it was noted that code violations are present on your property. The electrical service is unsupported, an unsafe condition. Please contact an electrician to make corrections. U Required for Occupancy Occupancy Item # Code NEC 230.51 Compliance No Compliance Date 07/14/2007 Description Service entrance conductors shall be supported by staples or other approved means. 12" from service heads and enclosures, 30" intervals. 06/14/2007 Last Updated 12786 Page 1 of 2 G OSHKOSH ON THE WATER Issue Date 6/14/2007 INSPECTION SEFWlCES DIVISION ROOM 205 DEPARTMENT OF COMMUNITY DEVELOPMENT CORRECTION NOTICE CITY OF OSHKOSH 215 CHURCH AVE PO Box 1130 OSHKOSH WI 54903-1130 Compliance Date 7/14/2007 Compliance No Address 721 VINE AVE l!:J Owner Name i TITAN STUDENT HOUSING LLC Address 3200 E CANVASBACK LN City APPLETON State Zip Code WI 54913 -0000 Sent to U Required for Occupancy Occupancy Introduction While conducting a routine neighborhood inspection it was noted that code violations are present on your property. The electrical service is unsupported, an unsafe condition. Please contact an electrician to make corrections. 06/14/2007 Code NEC 230.27 & 28 Compliance No Compliance Date 07/14/2007 Multiconductor cables used for service drops shall be attached to buildings or other structures by fittings identified for use with service conductors. For the support of service-drop conductors, the attachment point shall be of adequate strength or besupported by braces or guys o withstand safely the strain imposed by the service drop. Item # 2 Description Last Updated Summary Please make arrangements to have these violations corrected in the next 30 days. Feel free to contact me with any concerns :>r questions at 236-5274. Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 7/14/2007 Office hours for obtaining permits are Monday through Friday 7:30-8:30 a.m. and 12:30-1 :30 p.m. or by appointment. To schedule inspections please call the Inspection Request line at 236-5128 noting the address, permit number (when applicable), and the nature of what needs to be inspected. Signature Date Inspected by: Adam Krause 236-5274 akrause@cLoshkosh.wi.us - I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes. Print Name Company Signature Date Also Sent to: U Bldg ~ U Elec I U HVAC I U Plbg I U Designer I U Other I U Inspector I 12786 Page 2 of 2