HomeMy WebLinkAboutProject Closed
CITY HALL
Inspection Services Div
215 Church Avenue
DO Box 1130
@ Oshkosh WI
~ 54902-1130
OfHKOfH
ON THE WATER
City of Oshkosh
PROJECT CLOSED - 6/06/2007
Reviewing the file for 248 Wisconsin, it was noted that aCertifipate of
Occupancy has not been issued for Harry's Bookstore referenced by
Building Pennit 120555 issued 7/17/2006. The file has been closed.
. A Final Electrical Inspection has not been approved.
. A Final Plumbing Inspection has not been approved.
Without a Certificate of Occupancy there may be delays with any future sale
or refinancing of the property. Additionally, occupancy without a
Certificate of Occupancy is a violation of the Oshkosh Municipal Code.
cc: Smet Construction Services
Building Permit Work Card
Job Address 218-252 WISCONSIN ST Permit Number 0120555 Create Date 7/17/2006
Owner HIWISCA LLC Contractor SMET CONSTRUCTION SERVICES
Category 232 - Alteration Stores & Customer Service Plan U4-72-0706
Occupany Permit Required Flood Plain Height Permit Class of Const: VBibc
Use/Nature ~48 Wisconsin - Harry's Bookstore - Interior alterations to finish this tenant space for Bookstore."
of Work
HV AC.C~()ntr."UNKNO\lVN:??? ..... ."", . ",~-,...,.' <- ,. ,l;'lum!>i(lg<;Qntr:,JUBBlffPl.l,IMi:3INGJNC_- . .,"'," . '0' _,.,.._'-,' .~~:: '..':J,...,,,.,....:_~.~,..,...,'_:,'-.,. -".:',,-",'.
Electric Contr UNKNOWN????
Inspections:
Date 8/25/2006 : AM Type Final Inspector Allyn Dannhoff not approved
See FCN - Spoke to SMET- Shawn McKefreey (920) 621-6986 about the lack offinallnspection/Occupancy Approval, no Electric permit,
HV AC approval - AD
DatelTime requested: Notice Type: Ready DatelTime:
Access: I
Requested By: Phone Number:
o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid
--- - - - - -- - - - - - -- - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - -':'~:'::);"':;'f',~t,~7~~4'::~~7;'7,:<~-~ - --- - - - - - -.~ ~- - - - - - -- - - - - - - - -- - - - - -- - - - ~ - -- - - - - - -- - - - - - -- - - - - - - - - - - - - - - - - -- - - - - - -- - - - - -- - - - - - --- - - - - -- - - - - --
Date 5/16/2007: Type 'Final . ,. Inspector Allyn Dannhoff approved
Datemme requested:
Access: I
Requested By:
o Reinspect Fee 0 Fee Waived
Notice Type:
Ready DatelTime:
Phone Number:
o Reinspect Fee Paid
- - - - - --- - - - - -- - - - - - - - - - - - - - -- -- - - - - - - - - - - - - - -- - - - - - -- - - - - - - - -- - - - - -- - - -- - - -- - - - - - - - -- - - - - - - -- - - - - - -- - - - - - -- - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - -- - - - - - -- - - - - --- - - - - --- --
Page 1 of 1
Electric Permit Work Card
Job Address 218-252 WISCONSIN ST Permit Number 121449 Create Date 7/17/2006
Owner HIWISCA LLC Contractor OLSON ELECTRIC LLC
Service b New 0 ChangeO Temp . N/A I Type 0 Overhead 0 Underground. N/A
Volts Circuits 6 Luminaires
Value
$1,986.00
Amps
Use/Nature
of Work
Switches Receptacles 12
643 - Commercial-Addition/Remodels 248 Wisconsin. - Harry's Bookstore - Interior alterations to finish this tenant space
or Bookstore. *
Inspections:
Date
request II",
Date/Time requested: 09/11/2006 08:39 AM
Access:
Type Final
Inspector Kevin Benner
no time
Notice Type:
Ready Date/Time: 09/11/2006 08:39 AM
Requested by: OLSON ELECTRIC LLC - James Olson
o Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid
Phone Number: 920-366-9427
HVAC Permit Work Card
Job Address 218-252 WISCONSIN ST Permit Number 121514 Create Date 07/17/2006
Owner HIWISCA LLC Contractor CENTRAL HEATING SERVICE INC
Fuel I Gas I U Oil I U Electric I U Solar U Solid I Value $5,778.00
System 0 New I 0 Replace I 0 Other I
~ Forced Air U Radiant I U Steam I U AlC I U Vent I
U Electric I U Hot Water I U Suppl. I U Con. Burner I
Chimney Type 0 Chimney A 0 Chimney B . Direct Vent 0 Not Applicable
Use/Nature 48 Wisconsin - Harry's Bookstore - Alterations to duct work and addition of exhaust as per plans.
of Work
Inspections:
Date 5/16/2007
Type~Frn~r.'
......,,....', ,j
Inspector Allyn Dannhoff
approved
Date/Time requested:
Access: I
Requested By:
o Reinspect Fee 0 Fee Waived
10:09 AM
Notice Type:
Ready Date/Time:
Phone Number:
o Reinspect Fee Paid
Plumbing Permit Work Card
Job Address 218-252 WISCONSIN ST Permit Number 120670 Create Date 07/17/2006
Owner HIWISCA LLC Contractor TURRIFF PLUMBING INC
Category 440 - Industrial-Interior Plan Value $2,000.00
Bathtub - Shower - Water Softner Wait. St. - Shamp Sink - Coffee Maker 1
- -
Whirlpool - Floor Drain - Local Waste Ice Chest - FlrlWst Sink - Int Grease Trap
- -
Lavatory - Lndry Tray - Clothes Wshr Exam Sink - Catch Basin - Ext Grease Trap
- -
Toilet Disposal Bidet Sculry Sink 1 Wash Ftn - RPZ Valve
- - - - -
Res. Sink - Dishwasher Beer Tap Hand Sink Urinal Eye Wash Statn
- - - - -
Bar Sink - Sump Pump - Lab Sink Plaster Sink - Standp Rec - Wtr Sewer Mtrs
- -
Water Heater 1 Classrm Sink Sterilizer Surgeons Sink Ice Maker Deduct Meters
- - - - - -
Site Drain - Breakrm Sink - Dip Well - F Prep Sink - Gar Drain - Wtr Usage Mtrs -
Roof Drain Ejector/Grind Drink Ftn Serv Sink 1 Soda Disp
- - - - -
Misc. -
Fixtures
Use/Nature ?48 Wisconsin - Harry's Bookstore - Interior alterations to finish this tenant space for Bookstore.*
of Work
Size Material Type # Conn.Type
Sanitary Sewer
Storm Sewer
Water Service
Inspections for Work Card 87462
Date 7/25/2006 Type Rough In Inspector Paul Wolf
not approved
EXT 5050 / Ready for inspection at 248-B Wisconsin St (Harry's Bookstore)Per Comm 84.30 nail plates shall be installed to protect piping. Per Comm 82.40
water heater relief valve shall discharge to approved receptor. Spoke with Turriff.
DatelTime requested: 7/25/200612:28 PM Notice Type: Telephone Number: (920) 621-2029
Access: I
Ready DatelTime: 7/25/2006 12:28 PM Requested By: TURRIFF PLUMBING INC - Scott Turriff
o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid
- -- - - - - - - - - - - - - --_. - - --- - - - - - - --- - - - - - -- - - - - - - - - -- - - - - - - --- -- - - - - -- - - - - - -- - -- ---- - - - - -- - - - - - ---- - - - - --- - - - - -- - - - - - --- - - -- -- - -- - - -- - -- - - - - ---- - - -- - -- -- - -- - --. - - - - -- - - --- - ----- - - --- - ---- - -- -- - - - -- - --
Date 1/16/2007
Type Final
Inspector Paul Wolf
not approved
Backflow preventers required at service sink faucet, coffee brewer and expresso machine per Comm 82.41. Permit required for additional coffee brewer and
expresso machine.
DatelTime requested: 1/16/200707:42 AM Notice Type: CC Telephone Number:
Access: I
Ready DatelTime: 1/16/2007 07:42 AM Requested By: TURRIFF PLUMBING INC
o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid
- - - - - - ---- - - - -- - - -- - - - - ---- - -- --- - -. - - - -- - - - - - - - - -- - - - - - _.- -- - - - - - -- - - - - -- - - -- -- - - - - - - - - -- - - --- - - - -- - - - - - - - - -- -- - -- - - - - --- - - - -- - - - - --- - - - - -- - - - - - - -'-- -- - - - - -- - - - - - - - - - --- - - - -- - - - -...- - - - - - - -- - - - -----
~
CORRECTION NOTICE / FIELD INSPECTION REPORT
JOB LOCATION: .2 Jj B /AJ ,'s-Co ~:s I VI
CONTRACTOR: -S 11/I f'J ~
PROJECT TO BE INSPECTED: /.z ~..J---~; /
TYPE OF INSPECTION: ~"-Ci-I
~
City of Oshkosh
Inspection Services Division
215 Church Avenue, PO Box 1130
Oshkosh, WI 54903-1130
Phone: (920) 236-5050
Fax (920) 236-5084
Violations must be corrected and approved within 30 days unless otherwise noted. Call for re-inspections prior to concealment
and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of
l1'EMf{, 'GODE INSPECTION ~ULTS
t-
Post-it@ Fax Note 7671
To Fro
Co.
Phone # Phone #
{ Fax #
Print Name
Company
Signature:
Date
r
i
~
OJHKOJH
City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903-1130
www.ci.oshkosh.wi.us
ON THE WATER
July 13, 2006
Diana Dorschner
Dorschner Associates Inc
849 East Washington Ave, Suite 112
Madison, WI 53703
Eric Schwartz
Sara Investment Real Estate
1612 N High Point Road, Suite 201
Middleton, WI 53562
Site: Plan Number: U4-72-0706
Harry's Bookstore
248 Wisconsin Street
Oshkosh WI 54901
For:
Description: Tenant space alterations
Object Type: Building only
Class of Construction: VB -2386 Sq Ft.; Unsprinklered
Occupancy: M: Mercantile I Retail
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements 'ii-
Key Item(s) I Conditions:
· IBC 711.3 Any penetrations of fire rated assemblies are required to be protected with a listed firestopping
system that matches the rating of the wall assembly being penetrated. Copies of the firestopping systems
are required to be provided at the time of inspection.
· IBC 906.1 /IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet.
· IBC 1003.2.10 Exit signs are required to be installed per this section
· IBC 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress
through The Retail Display area are required to have adequate emergency lighting to meet the performance
requirements ofIBC 1003.2.11.3. Provide complete emergency lighting plan showing compliance with
these requirements prior to installation of emergency lighting system.
· NEC 110.26 Spaces About Electrical Equipment. Sufficient access and working space shall be
provided and maintained about all electric equipment to permit ready and safe operation and maintenance
of such equipment. Caution - if room 101 is used for a storage closet clearance in front of panel is
require to be maintained
· Comm 61.30(3) This review does not include lighting. Comm 63.0001 Prior to installation, lighting
plans and calculations shall be prepared in compliance with the code. The plans shall be available upon
request.
n :,(;;;;)"n'201;( (omm Pkm Revie'.v\U4-72.0706 148 wi,,',nsin St BJdg Only.doe
Page 1 of2
· Comm 61.30(3) / IMC 507.2 This plan review does not include heating, ventilation, or air
conditioning. HVAC plans are required to be submitted and approved prior to installation of HVAC
equipment.
· Comm 80 This plan review does not include plumbing. Prior to installation of plumbing, plans and
calculations are required to be submitted and approved. Contact plumbing inspector Rich Wood (920)
236-5049 to review grease interceptor requirem ents for food and beverage area.
· Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm 61.31(1).
· Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
· MUN 15 NOTE: Contact Anne Boyce - Health Services (920) 236-5029 for additional information as to
Health code requirements.
· MUN 30-35 (1)(5) All roof top and ground level mechanical equipment and utilities shall be fully screened
from view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236-
5062 for additional information on screening requirements. All screening shall be properly anchored in
place to resist wind loads. Additionally IDC 1608.8 Roofprojections - Drift loads due to mechanical
equipment, penthouses, parapets and other projections above the roof shall be determined in accordance
with Section 7.8 of ASCE 7.
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All pennits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead.
~
;~~
Building Systems Consultant
(920) 236-5051 Monday- Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
Fee Required $
Fee Received $
Balance Due $
320.00
320.00
0.00
Corrnn Phrn H.e\"le\v\LT4-72H0706 243 wis~Tmsin St Hldg (lrJy.dDc
Page 2 of2
~
OJHKOJH
City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903-1130
www.ci.oshkosh.wi.us
ON THE WATER
Sept 9,2006
Bryan Blom
HV AC Design Resource LLC
W364 Shady Road
Seymour, WI 54165
Jerry Van Grinsven
Central Temperature Inc
1054 American Drive
Neenah, WI 54956
Eric Schwartz
Sara Investment Real Estate
1612 N High Point Road, Suite 201
Middleton, WI 53562
Site: Plan Number: U4-72-0706-H
Harry's Bookstore
248 Wisconsin Street
Oshkosh WI 54901
For:
Description: Tenant space alterations
Object Type: HVAC only
Class of Construction: VB - 2386 Sq Ft.; Unsprinklered
Occupancy: M: Mercantile / Retail
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Hem(s) / Conditions:
· Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall b~ approved in writing by the department or its
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm 61.31(1).
· Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component.
pondence may be made to me at the number listed below or the address on this letterhead.
Respec
Brian
Building Systems Consultant
(920) 236-5051 Monday - Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1 :30 P.M.
bnoe@ci.oshkosh.wi.us
Fee Required $
Fee Received $
Balance Due $
230.00
230.00
0.00
Comm Plan Revie,':"J!4-72-0706-H 248 wisconsin 51 HV AC Only.do,;
Page lofl
\