Loading...
HomeMy WebLinkAboutLetter-State Variance approval , ,. fi1t..Ji commerce.wi.gov ~1!~9J~!Jen Safety and Buildings 141 NW BARSTOW ST FL 4TH WAUKESHA WI 53188-3789 TOO #: (608) 264"8777 www.commerce.wi.gov/sb/ www.wisconsin.gov Jim Doyle, Governor Mary P. Burke, Secretary March 28,2007 CUST ID No. 865345 A TIN: Buildings & Structures Inspector DAVID DEWHURST AHERN FIRE PROTECTION 201 MORRIS CT FOND DU LAC WI 54936-1316 BUILDING INSPECTION CITY OF OSHKOSH POB 1130 OSHKOSH WI 54902 APPROVAL OF PETITION FOR VARIANCE Identification N1lIllbers Transaction In No. 1373497 Site In No. 612756 Please refer to both identification numbers, above, in all corres ondence with the a enc . SITE: Shooters Nightclub 1014 Ohio St City of Oshkosh, 54901 FOR: Petition for Variance NFPA 13 - 15.1.3 The submittal described above has been reviewed for equivalency to applicable Wisconsin Administrative Codes and compliance with Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in section 101.01 (1 0), Wisconsin Statutes, is responsiblefor compliance with all conditions of this petition approval and other applicable code requirements. Plan submittal and approval to the department or its agent maybe necessary prior to construction undertaken per this petition. Your Petition for Variance of code section noted above has been reviewed. The code section petitioned requires combination water mains serving both domestic water and sprinkler systems be a minimum of 6 inches in diameter. The variance requested is to allow the use of an existing four inch water main for both domestic and fire protection supply. The intent of the code section petitioned is make sure that an adequate water supply is provided for the fire protection systems. The petitioner submitted the SB-9890 application form including several additional pages of supporting documents and pl~s. Reviewer's Comments: 1. The local fire department and municipal building inspection department reconimends approval based on the following conditions: That the sprinkler system flow requirements are proven with a water flow test after installation is complete. ~::u~:~~~g in question is an approximately 12,000 square foot existing building to be ~Eef-IVE 0 3. The building construction is Class VB. 2. Departmental Action: CONDITIONAL ApPROVAL APR 03 ." Reviewer's Conditions of Approval: DEPARTMENT OF · The automatic fire sprinkler system shall be installed in accordance with NFPA 13. COMMUNITY DEVELOPMENT · The automatic fire sprinkler system shall be monitored by an approved supervising station per NFP A 72. DAVID DEWHURST Page 2 3/28/2007 · The sprinkler system shall be hydraulically calculated to prove that the existing four inch watermain is adequate to supply the fire protection and domestic needs. Seventy gallons shall be added to the fire protection calculations to prove that both can be supplied simultaneously. All of the petitioner's statements of fact or intent included on the variance application form, any other documents submitted to the Department, as well as any other conditions of approval listed below, shall be carried out. Any recommended conditions of approval by the fire department and/or municipal building inspection department listed above shall also be carried out unless otherwise stated below. This variance is specific to the subject petition and cannot be used for any additional modifications. This decision will become fmal unless the department within 30 days from the date of this letter receives a written request for a hearing. A request for hearing should be sent to the address shown on this letterhead. A copy of this letter must be included with the request for a hearing. The request for hearing should state the reasons for objecting to the department's decision, because a request for hearing may be denied if it does not present a significant question in fact, law or policy. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Fee Required $ Fee Received $ Balance Due $ 500.00 500.00 0.00 Keith Glaunert, P.E. Fire Protection Engineer, Integrated Services (262)548-8604, M - F 7:30 AM - 4:00 PM keith. glaunert@wisconsin.gov wtsMART'~odi~'1P48 Mgmt. Prec. Review by: Dan Meneguin cc: Peter R Ochs, State Building Inspector, (920) 948-3500, Friday, 7:45 A.M. - 4:30 P.M. Stuart Schrottky, Battalion Chief, Oshkosh Fire Dept . Jim Paulson, Fluor Development