HomeMy WebLinkAbout12623-Electric/Building (05/18/2007)
e
OSHKOSH
ON THE WATER
Issue Date 5/18/2007
INSPECTION SERVICES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance Date 6/17/2007
Compliance No
Address
609 WAUGOO AVE
Sent to
Name
~ Owner~ SARAH J SHEW
Address
609 WAUGOO AVE
City
OSHKOSH
State Zip Code
WI 54901 .5130
Introduction
While investigating the electrical violation created between your property and 607 Waugoo Ave, the following violations were
noted specific to your property. l
U Required for Occupancy
Occupancy
Item # Code Muni Code 7 & 8 Compliance No Compliance Date 06/17/2007
Description No building or structure or any part thereof shall be moved, built, enlarged, altered, or demolished within the City unless a permit is obtained.
here is no permit on record for the hot tub structure and greenhouse at this address.
05/18/2007
Last
Updated
Item # 2
Description
05/18/2007
Code NEC 400.8 Compliance No Compliance Date 06/17/2007
Flexible cords--Uses Not Permitted: (1) As a substitute for the fixed wiring of a structure (2) Where run through holes in walls, structural
Iceilings, suspended ceilings, dropped ceilings, or floors (3) Where run through doorways, windows, or similaropenings (4) Where attached to
building surfaces. /
l.ast
Updated
12623
Page 1 of 2
G
OSHKOSH
ON THE WATER
Issue Date 5/18/2007
INSPECTION SERVICES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance Date 6/17/2007
Compliance No
Address
609 WAUGOO AVE
Sent to
Name
~ Owner ~ SARAH J SHEW
Address
609 WAUGOO AVE
City
OSHKOSH
State Zip Code
WI 54901 -5130
U Required for Occupancy Occupancy
Introduction
While investigating the electrical violation created between your property and 607 Waugoo Ave, the following violations were
noted specific to your property.
Item # 3 Code NEC 230 & 300 Compliance No
Description 'Installation of overhead electrical feeder to garage contains multiple violations.
Compliance Date 06/17/2007
05/18/2007
Last
Updated
,
Summary Please make arrangements to have these violations corrected in the n~xt 30 days. Feel free to contact me with any concerns
or questions at 236-5274. '
Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment
and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 6/17/2007
Office hours for obtaining permits are Monday through Friday 7:30-8:30 a.m, and 12:30-1 :30 p.m. or by appointment. To schedule
inspections please call the Inspection Request line at 236-5128 noting the a~dress, permit number (when applicable), and the
nature of what needs to be inspected. :
!
Signature Date
Inspected by: Adam Krause 236-5274 akrause@cLoshkosh.wLus
I hereby certify the violations listed on this report have been corrected in compli~,nce with the applicable codes.
Print Name
: Company
Signature
Date
Also Sent to: U Bldg I
U Elec I
U HVAC ~
U Plbg I
U Designer I
o Other ~
DTr1spector J
12623
Page 2 of 2
No permits for hot
tub and structure
Mun. Code Ch. 7 &
8
Violation(s) of: 609 Waugoo Ave.
Extension cords
cannot replace fixed
wiring. NEC 400.8
Taken by Adam Krause
609 Waugoo Ave 5-16-071
Overhead spans 150 volts
to ground shall be 10’
above ground. UF cable to
be sunlight resistant and
protected from physical
damage.
NEC 300.16 A box or terminal
fitting having a separately bushed
hole for each conductor shall be
used wherever a change is made
from nonmetallic-sheathed cable to
Violation(s) of: 609 Waugoo Ave.
open wiring. A fitting used for this
purpose shall contain no taps or
splices.
NEC 230.27 - Multiconductor
cables used for service drops
shall be attached to buildings or
other structures by fittings
identified for use with service
conductors.
Taken by Adam Krause
609 Waugoo Ave 5-16-072
Ch. 7 & 8
No permit for
structure Mun. Code
Extension cords
cannot replace fixed
Violation(s) of: 609 Waugoo Ave.
wiring. NEC 400.8
Taken by Adam Krause
609 Waugoo Ave 5-16-073
NEC 410.4(A) All
luminaires (fixtures)
installed in wet locations
shall be marked, ``Suitable
for Wet Locations.''
Violation(s) of: 609 Waugoo Ave.
Taken by Adam Krause
609 Waugoo Ave 5-16-074