HomeMy WebLinkAboutBuilding Y5-1987-0507
~
OJHKOfH
City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903-1130
www.cLoshkosh.wi.us
ON THE WATER
May 18, 2007
Roger Daniels
Building Service Inc
1195 West Carman Ave
Milwaukee, WI 53225
Dwnke & Associates LLC
222 Ohio St
Oshkosh, WI 54902
Site: Plan Number: Y5-1987-0507
The Star Group
430 N Koeller St
Oshkosh WI 54902
For:
Description: Tenant space alterations
Object Type: Building only
Class of Construction: IllB - 2714Sq Ft.; Unsprinklered -Non Separated Use
Occupancy: B: Business / Office
Maximum No of Occupants: 30
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Item(s) I Conditions:
. ANSI 404.2.3 Doorways shall have a clear opening of 32 inches minimum. Caution on sliding door, and
hardware used on these doors.
. IBC 906.1/ IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet.
. IRC 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress
are required to have adequate emergency lighting to meet the performance requirements ofIRC
1003.2.11.3. Provide complete emergency lighting plan showing compliance with these requirements
prior to installation of emergency lighting system.
. Comm 62.1109 (4) Kitchens, kitchenettes and wet bars. Where kitchen, kitchenettes and wet bars are
provided in accessible spaces orrooms, they shall be accessible in accordance with ICC/ ANSI A 117.1.
Elevation 6 on Sheet A2.1 does not appear to comply with accessibility requirements for counters, verify
compliance with ANSI A117.1 requirements
l:\Inspediuns\Pbn Review\Corrrmercial Pian Review 2007\Y5-1987-()S07-i30 N KoeHer 51 Bldg Only.do,
Page 1 of2
· IDC 2406.2 Glazing in an individual fIxed or operable panel adjacent to a door where the nearest exposed
edge of the glazing is within a 24 inch arc of either vertical edge of the door in a closed position and where
the bottom exposed edge of the glazing is less than 60 inches above the walking surface is requires safety
glazing materials. The windows in the Lobby, Vestibule, and Hoteling rooms adjacent to doors will need
to be glazed with safety glazing materials.
· IDC 2902..1/ Table 2902 Drinking water is required to be provided, since no drinking fountain is shown
on plans a bottled water cooler is required to be provided.
· Comm 61.30(3) This review does not include lighting. Comm 63.0001 Prior to installation, lighting
plans and calculations shall be prepared in compliance with the code. The plans shall be available upon
request.
· Comm 61.30(3) / IMC 507.2 This plan review does not include heating, ventilation, or air
conditioning. HV AC plans are required to be submitted and approved prior to installation ofHV AC
equipment.
· Comm 61.31(4) Revision.s to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm 61.31(1).
· Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibilityfor designing a safe building, structure, or component.
Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead.
Brian oe
Building Systems Consultant
(920) 236-5051 Monday- Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
Fee Required $
Fee Received $
Balance Due $
390.00
390.00
0.00
I:\Irt,pedinns\Plan Review\('nnrmen:ial Pl:111 Review 2007\'15- I 987-0507430 N Ko<:ller S! IIklg Only.doc
. Page 2 of2