HomeMy WebLinkAbout0092746-Plumbing (interior)
....
'........ :..e,.
o~
OSHKOSH
ON THE WATER
Job Address 2230 HICKORY CT
CITY OF OSHKOSH
No 92746
PLUMBING PERMIT - APPLICATION AND RECORD
Owner JAMES MATHWIG
Create Date 01/17/2002
Contractor JIM'S PLUMBING
Category 410 - Residential-I nterior
Plan
Bathtub 1 Shower 1 Ejector/Grind 0 Dip Well 0 F Prep Sink 0 Gar Drain 0
- - - - -
Whirlpool 1 Floor Drain 1 Water Softner 0 Drink Ftn 0 Serv Sink 0 Soda Disp 0
Lavatory 2 Lndry Tray 1 Local Waste 0 Wait. St. 0 Shamp Sink 0 Coffee Maker 0
- - - - - -
Toilet 2 Lndry Stndp 0 Clothes Wshr 1 Ice Chest 0 FlrJWst Sink 0 Int Grease Trap 0
Res. Sink 1 Disposal 1 Bidet 0 Exam Sink 0 Catch Basin 0 Ext Grease Trap 0
- - - -
Bar Sink 0 Dishwasher 1 Beer Tap 0 Sculry Sink 0 Wash Ftn 0
Water Heater 1 Sump Pump 1 Dent. Oper. 0 Hand Sink 0 Urinal 0
- - -
Site Drain 0 Classrm Sink 0 Lab Sink 0 Plaster Sink 0 Standp Rec 0
- -
Roof Drain 0 Breakrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker 0
Use/Nature NSFR
of Work
Size
Material
Type
#
Conn. Type
Sanitary Sewer
o
o
o
o
o
Storm Sewer
o
o
o
o
o
o
o
o
o
o
Water Service
Valuation
$9,000.00
Plan Approval
$0.00
Permit Fees
$90.00
Issued By \L t^
Date 02/20/2002
o Permit Voided I
In the performance of this work, I agree to perform all work pursuant to rules governing the described construction.
Signature
Date
Address W-6166 GREENVILLE DRIVE
Agent/Owner
GREENVILLE WI 54942 - 0000
Telephone Number 757-5258 OR 757-64
'"
~2/20/2002 14:44 FAX 920 757 6482
,
-:::.t...
City of Oshkosh
Inspeetion Services Division
POBox 1130
Oshkosh, Wl54903-1130
Phone: (920) 236-5050
Fax: (920) 236.5084
~OO1l001
JIMS PLUMBING
~
OJHKOfH
ON THE WATER
Plumbiot! Permit Am>licatioo
I hereby apply for a permit to do and install the following plumbing on the premises hereinafter described, the work to conform to the
Wisconsin State Plumbing Code, in the performance of which all parties hereto agree to and ,are bound by said statutes.
Job Address Jd30 Hi<.Xoc~ c!.. Value (Jncludinglaboralldmaterials>.31()l1).~
Owner :J"IM .vrb('~ ~. Contrattor --:)ir\'l'~ VlWn.~
,
ll<1Single Family DDuplex DMulti-Family ORental DCommertial
Number of Fixtures:
Bathtub -L Lndry Slalldp
Whirlpool + Disposal
Lavatory Dishwasher
Toilet a Sump Pump
Res. Sink -L Ejector/Grind
Bar Sink Water Softner
Water Heater , Local Waste
ShoweT --L Clothes WsI1r
Floor Drain -L Bidet
lndry Tray -L Beer Tap
Lab Sink Classnn Sink
Plaster Sink Surgeons Sink
Sterilizer Breakrm Sink
Electric Contractor
Use I Nature of Workj.\5 r--
-'-
.--L
-L
-L
Date~- ;;u,..O~
Dlndustrial
Dent. Oper. Shamp Sink
Dip Well FIrlWst Sink
DrinkFl11 Catch Basin
Wait. St. Wash Fl11
Ice Chest Urinal
Exam Sinle Gar Drain
Sculry Sink Soda Disp
Hand Sink Coffee Maker
F Prep Sink lee Maker
Serv Sink Site Drain
Int Grease Ttap Roof Drain
Ext Grease Trap Slandp Rec
OR
o EIV form attached (If Replacement)
Size
Material
#
COnn. Type
Sanitary Sewer
Storm Sewer
Water Service
Type
. Application(s) and fee(s) can be brought to City Hall, Room 205 or mailed to Inspection Services, PO Box 1128, Oshkosh WI
54903-1128. Commencing work without pennit(s) will result in fees being doubled or $100.00 plus the Donnal permit fee,
which ever is greater.
OR
Check here if you want this processed through your account [!('
'Q4/02/2002 15:07 FAX 920 757 6482
JHlS PLUMBING
~ 002/002
WATER DISTRIBUTION DATASHEET
..
Date: April 2, 2002
Name: JIMS PLUMBING
Project: GM BUILDERS/JIM &. MARIE MATIIWIG
Street: 2230 mCKORY CT
~
Street: W6166 GREENVILLE DR.
City: GREENVD.,LE, WI. 54942
City; OSHKOSH
1. ~ Gallon per minute buiding demand, prcdominatly Flush Tank.
2. -1!Q Low pressure at the Main in Street.
3. --..:2 Lb loss from a 2.0 ft difference in elevation from Main in Street to the Water Meter.
4a. 1.5 Lb loss from a 15.0 ft 1" Copper Tube Type K ASlM B88 water service from the Main in Street to the curb stop.
- Pressure loss detemined using a C value of 130 , ill8ide diameter of .995 and a velocity of 6.8 ft per see.
4b. 3.2 Lb loss from a 32.0 ft I" Copper Tube Type K ASTM B88 water service from the curb stop to the Water Meter.
- Pressure loss detemined using a C value of 130, inside diameter of .995 and a velocity of 6.8 ft per see.
5. ~ Lb loss from a 3/4in Meter
6. ~ Lbs of pressure available at the Water Meter. This value is entered in (B) below.
The (A) value listed below is determined by using the following formula, then rounding the result up.
A = a.(C+DtE) x 100
F
A. ~ Pressure available for unifurm loss (psi/l00 feet of pipe).
B. 62.3 Lbs of pressure available at the Water Meter.
C. 20.0 Pressure needed at the controlling fixture. MASTER SHOWER VALVE
D. ~ Lb loss resulting from J..ilft difference in elevation from the Water Meter to the controlling fixture.
E. ----.& Lb pressure loss due to a serving the controlling fixture.
F. ~ Ft Developed length from the 45.0 ft actual length of piping from the Water Meter to the cotltrolling fixture.
,~
Maximun Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 1 1114 I 1/2 2 21/2 3 4
Actual f. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.93:5
Value arC 130 130 130 130 130 130 130 130 130 130
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 6.5 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 16 38 144 369 731" 1833
Maximum IT WSFU 8 0 17.5 34 60 110 270 480 776 1833
r"\
j
....
, '94/0212002 15: 06 FAX 920 757 6482
JIMS PLUMBING
Fixture Listing
Date: March 22, 2002
~ 0011002
..
. ,
..
.""
Street: W6166 GREENVILLE DR,
City: GREENVll.LE, WI. 54942
Project: aM BULDERS/JlM & MARIE MATHWIG ((O~ .rxt5
Street: 2230 HICKORY cr
City: OSHKOSH
Name: JIMS PLUMBING
Non Public Use Fixtures
Hot
Cold
Total
I Automatic Clothes Washer 1.00 1.00 1.50
I Bathtub, with or without shower head 1.50 1.50 2.00
I Dishwashing Machine 1.00 .00 1.00
3 Hose Bib, 1/2" diameter .00 9.00 9.00
I Kitchen Sink 1.00 1.00 1.50
I Laundry Tray, 1 or 2 compartment 1.00 1.00 1.50
1 Bathtub, lavatory and water closet - FT group 2.00 3.50 4.00
2-Y Shower Stall, lavatory and water closet FT - group G~ & ...3.00- '"'7 .-J.:5tt"'
Total Water Supply Fixture Units ..9...00-
16.4 Gallon per minute demand of the building. Predominatly Flush Tank / )-
30.3 Pressure available for uniform loss. For the table use .31.0
r~
44:00"
2,(
-2Mo-'
:J&
Maximun Allowable load for Copper Tube Type 1\1, ASTM B88
Nominal Size 1/2 5/8 3/4 I 1 1/4 11/2 2 21/2 3 4
Actual 1. D. .569 0 .811 1.055 1.291 1.527 2,009 2.495 2.981 3.935
Value of C 130 130 130 130 130 130 130 130 130 130
Velocity in fi per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 6.5 0 ]2.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 16 38 144 369 731 1833
Maximum FT WSFU 8 0 17.5 34 60 110 270 480 776 1833
? ( <l 0 ~> \j.,....t..,\a\l.~-"r-.., ti),
\tt..((,-\ lh.~,-. ~,
0. 10:00 AM.,
.:I J 30
,...t
a...,..,
\\""e;-4.'<~Pj~' \O~"
'\. t ' t 1 ili
<\h,.Jh,: \"'".f:r'~l~t.\~-'''<.t~<o\''''' () "- Y a
/~
/
-:?f
, &
~
;r.~
~ /h
~
t!:>
~
i
j