HomeMy WebLinkAbout0095475-Plumbing (interior)
~.~'.
o
OSHKOSH
ON THE WATER
Job Address 2155 HICKORY CT
CITY OF OSHKOSH No 95475
PLUMBING PERMIT - APPLICATION AND RECORD
Owner CLASSIC HOMES BY KUBA Create Date OS/29/2002
Category 41 0 - Residential-I nterior Plan
Contractor LARRY HANSEN PLBG
Bathtub 0 Shower 2 Ejector/Grind 0 Dip Well 0 F Prep Sink 0 Gar Drain 0
- -
Whirlpool 1 Floor Drain 2 Water Softner 0 Drink Ftn 0 Serv Sink 0 Soda Disp 0
Lavatory 4 Lndry Tray 1 Local Waste 0 Wait. St. 0 Shamp Sink 0 Coffee Maker 0
-
Toilet 3 Lndry Stndp 1 Clothes Wshr 0 Ice Chest 0 FlrlWst Sink 0 Int Grease Trap 0
-
Res. Sink 1 Disposal 1 Bidet 0 Exam Sink 0 Catch Basin 0 Ext Grease Trap 0
- - - -
Bar Sink 1 Dishwasher 1 Beer Tap 0 Sculry Sink 0 Wash Ftn 0
-
Water Heater 1 Sump Pump 2 Dent. Oper. 0 Hand Sink 0 Urinal 0
- - -
Site Drain 0 Classrm Sink 0 Lab Sink 0 Plaster Sink 0 Standp Rec 0
Roof Drain 0 Breakrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker 0
Use/Nature NSFR
of Work
Size
Material
Type
#
Conn. Type
Sanitary Sewer
o
o
o
o
o
o
o
o
o
o
Storm Sewer
Water Service
o
o
o
o
o
Valuation $10,076.00
Issued By J..( \tvI
I
Plan Approval
$0.00
Permit Fees
$126.00
Date 06/26/2002
D Permit Voided I
In the performance of this work, I agree to perform all work pursuant to rules governing the described construction.
Signature
Date
Address N-1044 TOWER VIEW DR
Agent/Owner
GREENVILLE
WI 54942 - 8683 Telephone Number (C)851-6863
.,.. ..
City of Oshlc~~lt.
Inspection Services Division
POBox 1130 ~
Oshkosh, WI 5490~-1130
Phone: (920) 236-5050
Fax: (920) 236-5084
$ loHo.- OD
~
OfHKOfH
ON THE WATER
Plumbine Permit A1!)llication
I hereby apply for a permit to do and install the following plumbing on the premises hereinafter described, the work to conform to the
Wisconsin State Plumbing Code, in the performance of which all parties hereto agree to and are bound by said statutes.
Job Addres. d.\':33 U,( tOl~ L.i Value (Incl"m. ".... "'" "'_"l.lh, CYJ(-., . 00 Date (0-,;:) <..j. - ~
Owner C'\ClcR'r (b~ LQ. Contractor U{)JY--{) n +>t mt\ \ ('\C .
~Single Family ODu~lex DMulti-Family DRental DCommercial Dlndustrial
Number of Fixtures:
Bathtub
Whirlpool
Lavatory
Toilet
-r
r
~
..L
L-
Water Heater -1-
)(Gas 0 Electric 0 Power Vent
Shower ~
Floor Drain ~
.I
Res. Sink
Bar Sink
Lndry Tray
Lab Sink
Plaster Sink
Electric Contractor
Use I Nature of Work
Sterilizer Breaknn Sink
Lndry Standp 1 Dent. Oper. Shamp Sink
Disposal ,- Dip Well FlrlWst Sink
-
Dishwasher -L Drink Ftn Catch Basin
Sump Pump ~ Wait. St. Wasb Ftn
Ejector/Grind Ice Chest Urinal
Water Sollner E1uIm Sink ) - Gar Drain
Local Waste Sculry Sink Soda Disp
.Clothes Wshr Hand Sink Coffee Maker
Bidet F Prep Sink Ice Maker
Beer Tap Serv Sink Site Drain
Classnn Sink Int Grease Trap Roof Drain
Surgeons Sink Ext Grease Trap Standp Rec
OR 0 EIV f6rm attached (If Replacement)
Sanitary Sewer
Type
#
Storm Sewer
Water Service
Size
Material
Conn. Type
. Application(s) and fee(s) can be brought to City Hall, Room 205 or mailed to Inspection Services, PO Box 1128, Oshkosh WI
54903-1128. Commencing work without pennit(s) will result in fees being doubled or SIOO.OO plus the normal permit fee,
which ever is greater.
OR
Check here if you want this processed through your account 0
~?
~-t
.. ^
~'^Ob Address 2155 !::iICKORY CT
Owner CLASSIC HOMES BY KUBA
regory 410 - Residential-Interior
Plumbing Perm~ Work Card
Permit Number 95475
Create Date OS/29/2002
Contractor
Plan
LARRY HANSEN PLBG
Shower II 2 Ejector/Grind 0 Dip Well 0 F Prep Sink 0 Gar Drain lLA
Floor Drain -----L3- Water Softner 0 Drink Ftn 0 Serv Sink 0 Soda Disp 0
Lndry Tray -L1 Local Waste 0 Wait. St. 0 Shamp Sink 0 Coffee Maker 0
Lndry Stndp -L1 Clothes Wshr 0 Ice Chest 0 FlrlWst Sink 0 'nt Grease Trap 0
-
Disposal -L1 Bidet 0 Exam Sink 0 Catch Basin 0 Ext Grease Trap 0
Dishwasher 11 Beer Tap 0 Sculry Sink 0 Wash Ftn 0
112 - -
Sump Pump Dent. Oper. 0 Hand Sink 0 Urinal 0
Classrm Sink 0 Lab Sink 0 Plaster Sink 0 Standp Rec 0
- - - -
Breakrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker 0
Value
$10,076.00
Dathtub 0
Whirlpool 11
Lavatory ~
Toilet ~
Res. Sink -L1
Bar Sink -----LJ-
Water Heater ~
Site Drain 0
Roof Drain 0
Use/Nature
of Work
rSFR
Size
Material
Type # Conn.Type
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Sanitary Sewer
Storm Sewer
~~
~/
~
I
i
Water Service
Date
Type
Inspector
U\&f
&./ J-rB !o?-
d
~\
t)~
DatelTime requested:
Notice Type:
Access:
r
Ready DatelTime: Requested By:
o Reinspect Fee 0 Fee Waived D Reinspect Fee Paid
-------------------------~-----------------------------------------------------------------------
\J r/J A
/- ~~T OK
~- e,'ir ow- ~- G-<" o~ f) K
l/^ &t ~,~ ~ b~~~)~~J
, W"'~.ER CALCULATION WORKSHEET FOR c. It'"; SiC
.E.
/~~,pS"
.NAME OF PRQJECT
INFORMATION REQUIRED TO CALCULATE WATER SERVICE sIZe
e~. .
1.
2.
Demand of building in building in gallons per minute.
WSFU's 3 .2
= (GPM) J t7. g
(feet) S
~
Differel'lce In elevation from main or external pressure tank to building control valve.
'.
3. Size of water meter (when meter is required) .5/8" --' 314" .:-. 1" $.,.., 1-1/2" _' 2" _' larger size
4.Devel~Ped length from main o~extemal pressure tank to building control valve. (feet) L/f{
5. ........Law pressure at main in .street or extem~i'pressure '~nk. (Ps~ 5'" t
CALCULATE WATER SERVICE PRESSURE LOSS
6.
.c; .s
7.
Low pressure at main in street or extemal pressure tank. (value of # 5 above)
. ~ .' '.
Determine pressure loss due to friction in /,1- Inch diameter
water service. Subtract value of "7"
(Water service piping material is ~ tift )
,
d.~
30
subtotal
8.
Determine pressure loss due to elevation,
(multiply the value of #,2 above by .434)
~.. ,- . .'t.. .:-, ~~: ~",> ~ ;<<~
Available pressure after the bldg. controlvalve.~(enter in "B" 'below) i
subtotal
2),83
Subtract value of "8" :2. / 7
9.
CALCULATE1liE PRI;$~lU~t;"YNLAB,~r:9B ~Ntfg"~M.~q;~~ (V~UEOF I~A")
.:,,:,,<.~.t;,: .",":., I?' <;-;."::;:.'::::<",.J -;_~_,:-, ,,:,S ':!"f~-':',-} .i': ,~,~ ! .. .~. .J
B. Available pressure after the. bldg. control valVe. (from "9" above)' .
. . ...". . ...... I
.J '
Value of "B~J ,# ~-.1
.~
C.
Pres~ure loss ofwa~r:p1~lel"(whenrneteJ'Is,:requlred)
Subtractyalue of"C" .2., .s .
~:~~ '~ .~
...
:J 5. 33
subtotal
D.
Pressure at controlling fixture.
(Controlling fixture Is 1- j /
Subtract value of "0" "J 1;7
5.33.
tJJj__
subtotaJ
Difference in elevation betweenth~in9 control valve
and ttte controlling fixture in feet . I . X' .434 psi/fl
Subtract value of "E" S, ;J c? .
subtotal
.. /3
\~,
F.
Pressure.Joss due. to water treaWtent deviCfi!s, Instantaneous ,
water beete~ and b,a~ow preventers which serve the .
controlling fixture.
(PressLJ~ loss due to )
Subtract value of "F" -()
subtotal : ','/-5
DivIde by value of "G- 7~
subtotal , (Jell .,
. , ..;-. /~
Multiply by : 100 /
" , , I 7 ~~
"A" =
/;
~. Qeveloped length from building controlva.lvf3 to controlling
~~Jn feet ~.,t1" X 1.5 . .
jJ~>{
.
,
, )
. (Water distribution piping material Is
..,.....,
r:
j':
, ,..'
A. Pressure available for uniform loss
$eo~79(R11")
Fixture' LbUng
~
Date: August 22, 2002
~
)
Name: LARRY HANSEN PLUMBING
Project: NSFR
Street:
Street: 2155 HICKORY CT
City:
City:
Non Public Use FixtureS
Hot
Cold
Total
1 Automatic Clothes Washer 1.00 1.00 1.50
1 Bar Sink .50 .50 1.00
1 Bathtub, with or without shower head 1.50 1.50 2.00
1 Dishwashing Machine 1.00 .00 1.00
3 Hose Bib, 1/2" diameter .00 9.00 9.00
1 Kitchen Sink 1.00 1.00 1.50
2 Laundry Tray, 1 or 2 compartment 2.00 2.00 3.00
2 Lavatory 1.00 1.00 2.00
1 Water Closet, gravity type flush tank .00 2.00 2.00
2 Shower Stall, lavatory and water closet FT - group 3.00 6.00 7.00
Public Use Fixtures
Hot
Cold
Total
1 Ice Maker .00 .50 .50
1 Wall Hydrant, 1/2" diameter hot and cold mix 2.00 2.00 3.00
~
)
Total Water Supply Fixture Units
13.00
26.50
33.50
21.4 Gallon per minute demand of the building. Predominatly Flush Tank
25.6 Pressure available for uniform loss. For the table use - 26.0
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 21/2 3 4
Actual I. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Value ofC 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 6 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835
Maximum FT WSFU 7.5 0 18 34 62 112 270 484 776 1835
o
I
/
..
Fixture LisHng
Date: August 22, 2002
~
)
Name: LARRY HANSEN PLUMBING
Project: NSFR
Street:
Street: 2155 HICKORY CT
City:
City:
Non Public Use Fixtures
1 Automatic Clothes Washer 1.00 1.00 1.50
1 Bar Sink .50 .50 1.00
1 Bathtub, with or without shower head 1.50 1.50 2.00
1 Dishwashing Machine 1.00 .00 1.00
3 Hose Bib, 1/2" diameter .00 9.00 9.00
1 Kitchen Sink 1.00 1.00 1.50
2 Laundry Tray, I or 2 compartment 2.00 2.00 3.00
2 Lavatory 1.00 1.00 2.00
1 Water Closet, gravity type flush tank .00 2.00 2.00
2 Shower Stall, lavatory and water closet FT - group 3.00 6.00 7.00
Hot
Cold
Total
Public Use Fixtures
1 Ice Maker .00 .50 .50
1 Wall Hydrant, 1/2" diameter hot and cold mix 2.00 2.00 3.00
Hot
Cold
Total
~
)
Total Water Supply Fixture Units
13.00
26.50
33.50
21.4 Gallon per minute demand of the building. Predominatly Flush Tank
25.6 Pressure available for uniform loss. For the table use - 26.0
I
Maximun Allowable load for CrosslillkedPolyethylelle (Pex) Tubing ASTM F876
Nominal Size 1/2 5/8 3/4 1 1 1/4 11/2 2 21/2 3 4
Actual I. D. .485 .584 .681 .875 1.069 1.263 1.653 0 0 0
Value arC 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 4.5 6.5 9 15 22 31 53 0 0 0
Maximum FM WSFU 0 0 0 5 7 15 58 0 0 0
Maximum FT WSFU 5 8 11.5 21.5 35 58 142 0 0 0
~
WATERDISTRIBUTIC>N DATASHEET
"
Date: August 22, 2002
~
)
Name: LARRY HANSEN PLUMBING
Project: NSFR
Street:
Street: 2155 HICKORY CT
City:
City:
1. 21.4 Gallon per minute buiding demand, predominatly Flush Tame
2. 54.0 Low pressure at the Main in Street.
3. .0 Lb loss from a ~ ft difference in elevation from Main in Street to the Water Meter.
4a.~ Lb loss from a 15.0 ft 1" Copper Tube Type K ASTM B88 water service from the Main in Street to the curb stop.
Pressure loss detemined using a C value of 130, inside diameter of .995 and a velocity of 8.8 ft per sec.
4b. 4.5 Lb loss from a 48.0 ft 1 1/4" PE Tubing CTS ASTM 2737 A WW A C901 water service from the curb stop to the Water Meter.
- Pressure loss detemined using a C value of 150, inside diameter of 1.060 and a velocity of 7.8 ft per sec.
5. 2.6 Lb loss from a lin Meter
6. 44.4 Lbs of pressure available at the Water Meter. This value is entered in (B) below.
The (A) value listed below is determined by using the following formula, then rounding the result up.
A = B-(C+D+E) x 100
F
A. ~ Pressure available for uniform loss (psi/1 00 feet of pipe).
'J
B. ~ Lbs of pressure available at the Water Meter.
c. ~ Pressure needed at the controlling fixture. PRSR BLNC SHWR VALVE-MASTER BATH
D. ~ Lb loss resulting from a 12.0 ft difference in elevation from the Water Meter to the controlling fixture.
E. .0 Lb pressure loss due to a WTR SFNR serving the controlling fixture.
F. 75.0 Ft Developed length from the 50.0 ft actual length of piping from the Water Meter to the controlling fixture.
Maximun Allowable load for Crosslinked Polyethylene (Pex) Tubing ASTM F876
Nominal Size 1/2 5/8 3/4 1 1 1/4 1 1/2 2 21/2 3 4
Actual I. D. .485 .584 .681 .875 1.069 1.263 1.653 0 0 0
Value ofC 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 4.5 6.5 9 15 22 31 53 0 0 0
Maximum FM WSFU 0 0 0 5 7 15 58 0 0 0
Maximum FT WSFU 5 8 11.5 21.5 35 58 142 0 0 0
~
)
138/22/2802 132:113
921375758137
.... '. . ~
...4. :, · --'
.:~ :.{'., "~UI.f. tHe
N~044 Tower View Orive' Greenville. WI 54942
M.P. 6981
Larry A. Hansen. 920-157-8863
TO
Classic Homes
Jim Kubasla
1~65 Gasti2bt Cl
Oshkosh WI 54904
w. he,eby lubmh Ipee;flclIlions and 88tiM.t86 tot:
KITCHEN:
KV.-.ltM' JOlid cm6l' sii'" IMSDB
1 Inlta 1470 WH or BISC -'. - '.
-tUistM'1IIiMr hi'4itk'Hp (l}W1 'w_1)'lw.~ -
1lSE *333 disposal l j
J ll1!'~"il!,.lilJ.'
1 Colored mise,
LOWER. LEVEL BAlH:
Hfl A"ld I~.n 1252
1 Delta tIl2567/H2.,
I-ARt S'A{.r:gl8Ss ShtJl._ .fS68
1 Delta ~14241H7~
I M-..Geld t.Gitd. *n~v./Jcet
1 Delta Trad. 24," towel bar ~,q401A CH
1 Delta Trad. Euro paper holder #74050 CH
HANSEN PLUMBING INC
- .---,
PAGE 84
Po,. No. 1 of
i 1"&9'"
.B:C ()
PROPOSAL
~
j
PHOIlll
426-8600
JOB NAME I :c;:~~
''The pum dO<
City sew~,' &, water
J/
[)I\'fe
ll.rJ1!2QOl
JOB NuMBER
MASTER BATIl:
~Mdll:di",t.llavs 1#2,~~.
2 Della H2.567/JU5
...4 .\fter ~. fit>,,"lgl~;:. t.bvvvr.l #560
1 Delta #1424lH75
fl I' I t 142"" .1 I H lI' ->
l-PJ'O t vv III Vl'(.'1 .1.. W' t<<) 61 ma () l 1111
1 Delta tt-276'hH65
1 Chrome ~lP drain
m8flS1i~ld UI,ild Ii ;J8..1OG 1'V1:reat
1 Delta Trad. 1.4" towel bar fH4024 CH
1 Delta Tract. Eu,,,., p~per h(lld~r #-'1-1050 CH
~
.
J
tOWER. LEVEL KITClIF.N AREA:
.t.SwllHtw" 1 'Sd.5 -sfiid~,' h-1b Jigk n '*"'~(1
1 Delta #190 ell.
o
J
08/22/2002 02:10
9207575807
; fi '
~~.~~ ,,".., II' ,.,:/. ~..
I~~'~.....'.""<< . I ' I .
~. ,. · ~,~... . N
'~'~~'f.\;~~~INC
" N1044-TdweI'Vle.,., Drive Greenville, WI 54942
! \
~ I, . M.P..-8981
" Larry A. Hansen. 920-751-6863
;
'TO
Classic Homes
Jim Kubasta
2.56~ Gaslitdd. Ct.
Oshkosh WI 54904
We heRby submit speciflcldiona and ..timlte. for;
POWDER. ROOM: White
i::Kvb. D..,.c...A~ _ 1 J" peel).... 11<'2286 ~
1 Delle Mo3567NN1H2'
1 Roll >>.. ~~ .Ior teifel NK3457 WISe-fit --
.". "l:lr'
.,. 1 Detta Trad. Euro paper boldtr *740~O NN
1 Delta Tnad.. 18" tv~. b.. *74018 NN
1 Trip Jevel" ~39 BN
lAUNDRY ROOM: '
: llllnL} "VA -
1.1fultee f19 h_*, 8*
1 Delta *115
HANSEN PLUMBING INC
, "PIG No, 1 of
PROPOSAL
PHONE
426.8600
JOB NAME I ~OCfTION
''The lflza-cf'
I DAn
I 12/2 i/2001
City ,ewer & water
j2/5S f/,.c It Q~ Y
\J08Pttd"NE
JOB NUMBER
BASEMENT:
150 Gal. Ilet gas B..veut heater
1 Submersible sunil' pump
1 Floor dnin
~J; 7 I4f' ~;
MIse: ~ - - tJ J
-3 ~..id8 hQr'" hihhs
/I.J ./.
I q a~ &4') .P ;::=::' J
"'Ct;th
-'
PAGE 05
2 PPle$,
"'-:
2331
....-,
j
/~
j
/~
./