HomeMy WebLinkAbout0074644-Plumbing (interior)
o
OSHKOSH
ON THE WATER
Job Address 2466 BLAKE CT
~
Contractor
Bathtub
Whirlpool
Lavatory
Toilet
Res. Sink
Bar Sink
Water Heater
Site Drain
Roof Drain
Use/Nature
of Work
Valuation
Issued By
CITY OF OSHKOSH
No 0074644
PLUMBING PERMIT - APPLICATION AND RECORD
Owner
HERITAGE HOMES OF OSHKOSH INC
Create Date 10/14/1999
JIM'S PLUMBING Category 410 - Residential-Interior
2 Shower 1 Ejector/Grind Dip Well F Prep Sink
-
Floor Drain 1 Water Softner Drink Ftn Serv Sink
3 Lndry Tray Local Waste Wait. St. Shamp Sink
-
3 Lndry Stndp 1 Clothes Wshr Ice Chest FlrlWst Sink
1 Disposal 1 Bidet Exam Sink Catch Basin
-
Dishwasher 1 Beer Tap Sculry Sink Wash Ftn
-
Sump Pump 1 Dent. Oper. Hand Sink Urinal
Classrm Sink Lab Sink Plaster Sink Standp Rec
Breakrm Sink Sterilizer Surgeons Sink Ice Maker
Plan
Gar Drain
Soda Disp
Coffee Maker
Int Grease Trap
Ext Grease Trap
NSFR
Size Material Type # Conn. Type
Sanitary Sewer
Storm Sewer
Water Service
$6,500.00
$0.00
Permit Fees
$64.00
Plan Approval
Date 12/06/1999
D Permit Voided I
Signature
In the performance of this work, I agree to perform all work pursuant to rules governing the described construction.
Date
Agent/Owner
GREENVILLE WI 54942 - 0000
Telephone Number 757-5258 OR 757-64
Address W-6166 GREENVILLE DRIVE
Plumbing Permit Work Card . . ..J
Permit Number ...ooe9~ 1 ~ ft.. rf;
Contractor JIM'S PLUMBING
Plan
Job Address 2466 BLAKE CT
Owner HERITAGE HOMES OF OSHKOSH INC
Create Date 10/14/1999
j"OD . ~
V -$e:OO
410 - Residential-Interior
II 2 Shower -L1
Floor Drain ~
Category
r ;htub
Whirlpool
Lavatory
Toilet
Res. Sink
Bar Sink
Water Heater ----L1
Site Drain
!..J.11
~
--L1
Roof Drain
Use/Nature
of Work
Lndry Tray
Lndry Stndp
Disposal
Dishwasher
Sump Pump
Classrm Sink
Breakrm Sink
Value
1
I 1
~
-11
Ejector/Grind Dip Well F Prep Sink
Water Softner Drink Ftn Serv Sink
Local Waste Wait. St. Shamp Sink
Clothes Wshr Ice Chest FlrlWst Sink
Bidet Exam Sink Catch Basin
Beer Tap Sculry Sink Wash Ftn
Dent. Oper. Hand Sink Urinal
Lab Sink Plaster Sink Standp Rec
Sterilizer Surgeons Sink Ice Maker
Gar Drain
Soda Disp
Coffee Maker
Int Grease Trap
Ext Grease Trap
I NSFR
Sanitary Sewer
Storm Sewer
.~
ha.ter Service
Size
Material
#
Conn.Type
If-{y II//? I
lZ { J1 / 1 bl CJ'i
r :2-1:2-1-
Type
Date 00/00/0000 Type
Inspector
__ LJ Approved]
~. .
. .
v. _~'! _,
,
~J
):-;; -- r: k D/j/V" d;
J-5~~-BPf P()K
\ ~ ~~f,J;-/~tVL ~ tJt:.
i~
! ,t"
,
;.;1. -~
.
':...,
..
f"\
FIXTURE LISTING SHEET
.~
Date: 10-19-1995 .
Purchaser's name here
Reference: Security Homes Inc.
Address: 2466 Blake Court
City: Oshkosh
NO. NONPUBLIC USE FIXTURES
1 Automatic Clothes Washer -------------------
1 Dishwasher ---------------------------------
4 Hose Bib 1/2 -------------------------------
1 Kitchen Sink -------------------------------
2 Bathtub, Lav & Water Closet-FT -------------
1 Shower, Lav & Water Closet-FT --------------
Hot Cold Total
1.0 1.0 1.5
1.0 0.0 1.0
0.0 12.0 12.0
1.0 1.0 1.5
4.0 7.0 8.0
1.5 3.0 3.5
Hot Cold Total
8.50 24.00 27.50
Total water supply fixture units
18.5 Demand of building in gallons per minute. Predominate flush tank
0.0 Gallons per min added for Cont. Flow Special fixtures & equip.
0.0 Water Supply Fixture Units added for Intermittent Flow equip.
24.1 Pressure available for uniform loss. For table use. - 25.0
Controlling fixture & location:
/~
MAXIMUM ALLOWABLE LOAD FOR COPPER TUBE TYPE M
PIPE SZ 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4
GPM 6.0 13.0 21.0 32.0 46.0 80.0 120 175 280
WSFU FM 0.0 4.5 7.0 16.0 40.0 148.0 365 740 1630
WSFU FT 7.0 18.0 32.0 60.0 113.0 275.0 475 780 1630
. .
~
.l ..
lit..
,
.
~
)
.
~
WATER CALCULATION WORKSHEET
Purchaser's name here
For: Security Homes Inc.
...-....
1. 18.5 Demand of building in gallons per minute.
/
2. 48.0 Low pressure at main in street (or at external pressure tank).
3. 2.0 Difference in elevation from main to meter (or external pressure
tank to building control valve) .
4. 3/4 Size of water meter (if applicable).
Sa. 15.0 Developed length from main to curb stop (if no curb stop then from
main to meter, or external pressure tank to building control valve) .
5b. 20.0 Developed length from curb stop to meter.
You Must First Find the Available Pressure After the Water Meter
(or at building control valve). To obtain this pressure, you must:
6a.
2.0
Find pressure loss due to friction in
service main to curb (If no curb stop
Find pressure loss due to friction in
service curb to meter.
1 K inch water
then from main to meter) .
1 Sc40 inch water
6b.
2.1
7.
0.9 Find pressure loss due to elevation, main to meter (or external
pressure tank to building control valve). Multiply the difference
in elevation by .434 p.s.i./ft.
8.
5.1 Find pressure loss due to meter (from manufacturer or AWWA).
~
)
9. 37.9 Subtract the loss due to friction (Step 6), loss due to elevation
(Step 7), and loss due to meter (Step 8) from the low main pressure
(or low pressure at external pressure tank). This calculation is the
available pressure after the water meter (or at the building control
valve). This answer is entered in line B, below.
WHERE:
A ; ((B -(C + D + E)) divided by F) X 100
A. 25.0 Pressure available for uniform loss (p.s.i./100' of pipe).
B. 37.9 Available pressure after water meter (at the building control valve
or low pressure at internal pressure tank). (See item 9. above).
C. 20.0 Pressure needed at controlling fixture.
D. 3.5 Diffe;~nce in elevation between water meter (building ~ontrol valve
or intE3+::nal pressure tank) and controlling fixture .~^
in fee't- 8.0 x .434 p.s.i./ft. r
<
E. 0.0 Pressure loss due to water softeners, water treatment devices,
instantaneous water heaters and backflow preventers which serve the
controlling fixture. Conventional water heaters usually do not have
a pressure loss. ~\
F. 60.0 Developed length from water meter (building control valve or
internal pressure tank) to controlling fixture in feet 40 x 1.5.
./