Loading...
HomeMy WebLinkAboutBuilding X8-1941-0307 if ~ OJHKOfH City of Oshkosh Divi ion of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.cLoshkosh.wi.us ON THE WATER March 28, 2007 Dale H Nelsen 202 E North St Appleton, WI 54911 James Willoughby His Curch W orId Outreach 2704 Jackson St 'Oshkosh, WI 54901 Site: His Church World Outreach 2704 Jackson St Oshkosh WI 54901 For: Description: Interior space alterations Object Type: Building only Class of Construction: 11m - Unsprinklered Occupancy: A: Assembly Plan Number: X8-1941-0307 The submittal described above has been reviewed for conformance with applicable Wisconsin Administra ive Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed' Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) / Conditions: . A Review of our records indicates that a 2nd exit that was required from the mezzanine ar a was not installed. Provide documentation that present day code would no longer require the 2" means of egress from the mezzanine or submit a schedule to complete installation as previously requir d. . ANSI 404.2.4.1 Maneuvering Clearances for a Manual Swinging Door. Swinging d orsshall have maneuvering clearances complying with table 404.2.4.1. Caution on doors that swing i to restroom - minim um 18 inches clear is required on the pull side on the latch side of the door. · IBC 906.1 / IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet. · IBC 1003.2.11 Means of egress illumination is required to be installed per this section. 1 paths of egress are required to have adequate emergency lighting to meet the performance requirements f IBC 1003.2.11.3. Existing means of egress emergency lighting is permitted to be maintain in compliance with the code in effect at the time of construction. Any altered path of egress, or new p th of egress, and any new emergency lighting being installed is required to comply with current cod requirements. · IBC 1209.1 Provide toilet room floors with smooth, hard, nonabsorbent surface extendin inches up onto walls. Ifflooring in restrooms is replaced it must comply with this sectio l:\l1lSpedimls\Plan .Revie'w\Commen:ial PlmJ Revi",w 2007\\.2-'1941-03072704 Jackson Sl BUg Only.doc Pag 1 of2 l. · IBC 2406.2 Glazing in an individual fixed or operable panel adjacent to a door where t e nearest exposed edge of the glazing is within a 24 inch arc of either vertical edge of the door in a closed osition and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface is requires safety glazing materials. VerifY that the windows that are being relocated comply with safe glazing requirements. · Comm 61.30(3) I IMC 507.2 This plan review does not include heating, ventilation, or air conditioning. HV AC plans are required to be submitted and approved prior to install a . n ofHV AC equipment. Be aware that IDC 1004.3.2.4 contains additional restriction for air movem t in corridors · Comm 61.31(4) Revisions to approved plans. All proposed revisions and modificatio s which involve rules under this code and which are made to construction documents that have previousl been granted approval by the department or its authorized representative, shall be submitted to the offi e that granted the approval. All revisions and modifications to plans shall be approved in writing by the d partment or its authorized representative prior to the work involved in the revision or modification bein carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in ccordance with Comm 61.31(1). · Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervi ing professional shall file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All pe ts are required to be obtained prior to commencement of work. . In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require hanges or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2 , nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or componen . Inquiries concerning this correspondence may be made to me at the number listed below or the address on . s letterhead. ~... Res". .. . . ...-""./~ . ~-.B' ~ Building Systems Consultant (920) 236-5051 Monday- Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 320.00 320.00 0.00 T:\InspediolJ~\P!an Review\Commen:ial Phm Reyiew 1007\,,8-1941-0307270"; Jackson St Bldg Only.doc Page of 2