Issue Date 1/8/2007
Address 1627 DOTY ST
Compliance No
Sent to
City
OSHKOSH
State Zip Code
WI 54902 -6945
Occupancy
Item #
Last
Updated
Code NEC 334.30 Compliance No Compliance Date 02107/2007
Nonmetallic-sheathed cable shall be supported and secured by staples, cable ties, straps, hangers, or similar fittings designed and installed so I
s not to damage the cable. Any cables exposed by the removal of building finish to reveal absence of support shall be brought into code. I
I
I
I
I
Description
01/08/2007
Item # 2 Code NEC 210.8(A){1) Compliance No Compliance Date 02107/2007
Description GFCI protection is required in bathrooms. The first floor bathroom, having partially opehed walls, shall have complian, GFCI protected
receptacles.
01/08/2007
Last
Updated
Item # 3 Code NEC 334.12(B){4) Compliance No Compliance Date 02107/2007
Description ITypes NM and NMS cables shall not be used under the following conditions or in the following locations: Where exposed or subject to
~xcessive moisture or dampness. Any NM cable which was exposed to water shall be replaced.
01/08/2007
Last
Updated .