Loading...
HomeMy WebLinkAbout12144-Electric Introduction INSPECTION SERVICES DIVISIO~ ROJM 205 . DEPARTMENTOF1COMMUNITY DEVEL6PMENT CORREttldN NdTICE I. . " 1:1 CITY OF OSHKOSH 215 CHURCH AVE POBox 1130 OSHKOSH WI 54903-1130 o OSHKOSH ON THE WATER Issue Date 1/8/2007 Address 1627 DOTY ST Compliance No Sent to City OSHKOSH State Zip Code WI 54902 -6945 Occupancy Item # Last Updated Code NEC 334.30 Compliance No Compliance Date 02107/2007 Nonmetallic-sheathed cable shall be supported and secured by staples, cable ties, straps, hangers, or similar fittings designed and installed so I s not to damage the cable. Any cables exposed by the removal of building finish to reveal absence of support shall be brought into code. I I I I I Description 01/08/2007 Item # 2 Code NEC 210.8(A){1) Compliance No Compliance Date 02107/2007 Description GFCI protection is required in bathrooms. The first floor bathroom, having partially opehed walls, shall have complian, GFCI protected receptacles. 01/08/2007 Last Updated Item # 3 Code NEC 334.12(B){4) Compliance No Compliance Date 02107/2007 Description ITypes NM and NMS cables shall not be used under the following conditions or in the following locations: Where exposed or subject to ~xcessive moisture or dampness. Any NM cable which was exposed to water shall be replaced. 01/08/2007 Last Updated . ~~\,j:.~:;; ~~'0 12144 Page 1 of 2