Loading...
HomeMy WebLinkAboutHVAC X4-1922-0207-H ~ OJI-KOfH City of Oshkosh Division of Inspection SelVices 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.ci.oshkosh.wLus ON THE WATER March 16, 2007 Arthur Warren Condon Total Comfort, Inc 11 Blackburn St Ripon, Wl54971 Derek G Maul GMA Structural 211 E Freistadt Rd Thiensville WI 53092 Fred Jacques Alliance Development 222 Ohio St. Oshkosh, WI 54903 Tim Boesch Lee-Allen Construction, LLC 936 Fredonia Ave. Fredonia WI 53021 Site: Plan Number: X4-1922-0207-B Enterprise Rent-A-Car 140 Koeller 8t Oshkosh WI 54902 For: Description: Tenant space alterations Object Type: BV AC only Class of Construction: VB -1930 Sq Ft.; Unsprinklered Occupancy: M: Mercantile I Retail non-separated use The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) / Conditions: . IMC 405.1 General. Mechanical ventilation systems shall be provided with manual or automatiq controls that will operate such systems whenever the spaces are occupied. Air-conditioning systems that supply required ventilation air shall be provided with controls designed to automatically maintain the required outdoor air supply rate during occupancy. Both the toilet room exhaust and the service sink exhaust is required to be run continuously when building is occupied. If this is accomplished by using the lighting circuit for control, the lights in area #5 shall be used for this rather than the lights in the car porter area, as indicated in the email dated March 15th . . IMC 920.1 General. Unit heaters shall be installed in accordance with the listing and the manufacturer's installation instructions. Oil-fired unit heaters shall be tested in accordance with UL 731. Verify that installation matches listing installation requirements for in a garage. . Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative; shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm 61.31(1). FlnsjJect.ion,\Plan Re\.'i~w\Commercial Pian R~vi~w ::OOTX4- i 922-0207-11 140 Koelkr St HVAC Only.do(; Page 1 of2 A copy of the approved plans, specifications, andthis letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made tome at the number listed below or the address on this letterhead. n oe Building Systems Consultant (920) 236-5051 Monday- Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 1:\lnspe.iio.ns\Pbn Fevi\;w\Commen:ial Pklll Review 2007\X4-! 922-0207-IlI.:!() Koe!kr St IIVAC Only.Joc Page 20f2 230.00 230.00 0.00