HomeMy WebLinkAboutWater Distribution Datasheet
/
,.
.;;;.-
WATER. DlSTRIlJUTION DATASlEIEET
"
Date: .'!Ir~J... . _..'
Name: Midwest
I'r<!ioct: duplex side with service
Street:
Strcct:
.J1.l t./y'uw"./ /.}t(
city: City:
I. 15.2 Gallon per minute buiding demand, prc:dominatly Flush T8IIk.
2. 43.9 Low preSSlll'C at the Main in the S1reet.
3. .0 No water servic;e.
4a.----& No water lateral.
4b.----& No 2nd part water lateral.
S. 3.5 psi loss from a 314in Meter
6. 40.4 psi ofpressure available at the Water Meter. Thi. value is ontered in (B) below.
The (A) va11'" Iistcd below is detemtined by using the following fotmula, thon rotIl1ding the reoo1t up.
A ~ B.{C+Dl-E) x 100
F
A ---.IT Pre.sure available foc 1lIIifonn loss (psi/100 feet of pipe).
B. ~ psi ofprc.me available at the Water Meter.
C. ~ Pressure needed at 1he controlling fixture. ba1htub
D. ---M psi loss resulting from a!!.!! it difference in elevation from the Water Meter to the controlling flXturc.
E. ~ psi pressure loss due to a no pressure 10.. devices serving 1ha controlling f1l<tllre.
F. 90.0 FtDaveloped 1eng1h from the 60.0 it actual length of piping from the Water Melet'to the controlling fixture.
Maximun Allowable load for Copper Tube Type M, AS1M ass
Nominal Size 1.12 5/g 3/4 I 11/4 11/2 2 2112 3 4
Actual 1. D. .569 0 .811 1.055 1.291 l.527 2,009 2.495 2.981 3.935
Value ofC 150 150 ISO ISO 150 ISO 150 ISO ISO ISO
Volocity in it per see. S 8 8 8 8 8 8 8 8 8
Maximum Gpm 5.5 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 17 39 144 374 731 1835
Maximum FT wsrn 65 0 IS 34 62 112 270 484 776 . 1835
..<
Fb:ture Listing
Date: -~~{ .
Name: Midwest
Project: duplex side with serv;oo
Street:
S1reet:
2/;1 ~MN"/Ø
City:
City:
Non Public Use Fixtures
I Automatic Clothes Washer 1.00 1.00 1.50
1 DishwasWng Machine 1.00 .00 1.00
2 Hose Bib, 1/2" diameter .00 6.00 6.00
1 Kitchc:n. SDIk 1.00 1.00 1.50
2 Bathtub, lavatory and water closet. FT group 4.00 7.00 S.OO
I Shower Stall, lavatory and water closet FT . group UO 3.00 3.50
Hot-
Cold
Total
Public Use Fixtures
Q Ice Maker
Hot .00 I COld.50 I
Total
.50 I
Total Water Supply Fixture Units
8.50
18.50
22.00
15.2 Gallon per minute demand of the building. Predominatly Flush TSIIk
16.4 Pressure available foc uniform loss. For the table use "'17.0
Maxlmlln Allowable load for Copper Tube Type M, ASTM B88
Nominal Size 1/2 5/8 3/4 I 11/4 11/2 2 21/2 3 4
Aètua1 I. D. .569 0 .811 1.055 1.291 1.527 2.009 2.495 2.981 3.935
Velue orc 150 150 150 150 150 150 150 ]50 150 ]50
Velocity m it per see. 8 8 8 8 S 8 8 8 8 8
Maximum Gpm 5.5 0 12.5 21.5 32 45 79 121 174 303
Maximum FM WSFU 0 0 4.5 7 17 39 ]44 374 731 1835
Maximum FT wsÞu 6.5 0 18 34 62 112 270 484 776 1835