HomeMy WebLinkAboutBuilding X4-1922-0207
~
O.lHKOJH
City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903-1130
www.cLoshkosh.wLus
ON THE WATER
March 2, 2007
Rory Palusiski
Fein Design LLC
11124 N Cedarburg # 320
Mequon WI
Derek G Maul ,
GMA Structural
I
2 liE Freistadt Rd
I. .!
Thiensville WI r092 .
Tim Boesch I I
Lee-Allen Construction, LLC
936 Fredonia A ~e. ;
Fredo~ia WI 53921 ,
I I
Plan Number: X4-1922-()207
I I
Fred Jacques
Alliance Development
222 Ohio St.
Oshkosh, WI 54903
Site:
Enterprise Rent-A-Car
140 Koeller St
Oshkosh WI 54902
For:
Description: Tenant space alterations
Object Type: Building only
Class of Construction: VB - 1930 Sq Ft.; UnsprinkIered
Occupancy: M: Mercantile / Retail non-separated use
Maximum No of Occupants: 25
I
I
I'
The submittal described above has been reviewed for coIlfonnancr with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALL'X APPROVED. The owner, as defined in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Item(s) / Conditions:
. IBe 406.6.2 Mixed occupancy. A repair garage shall not be located within, or attached to, a building
occupied for any other purpose, unless separated from the other occupancies as prescribed in Section
302.3.3. Such separation shall be continuous and unpierced, except for doors leading to salesrooms, or
offices, operated in connection with such garages, and provided such openings are equipped with seIf-
closing fire doors conforming to the requirements of Chapter 7. As long as the "Car Porter Area" is not
being used asa "Repair Garage", Section 302.3.2 Non-separated Uses allowsfor the entire building to
be classified under the most restrictive use, and not require fire separation based on the allowable area
for that use. In discussing this with the designer, the wall shown on theplan as being a 2 hr wall will
not be required to be rated. thereby not requiring head of wall join assemblies, andfire stopping
assemblies, and not requiring continuity of a fire r'ating with the eXisting wall identified as an existing
party wall that is currently an non-rated wall.
. ANSI 604.3.1 Clearance around the water closet shall be 60 incqes minimum measured perpendicular
from the side wall, and 56 inches minimum from the rear wall. No other fixtures or obstructions shall be
within the water closet space. Based on a discussion with the de{Jigner and contractor the vanity shown
on the plans is being replaced by a wall hung sink. Verify that'the required clearance is maintained.
hlnsped.ions\Plan n.t'view\Cornmt'n:ial Hm Revkw 2007\X4-1922-0207 14D Kn<.Ib' :;. BId:; Only.(kh:
Page 1 of3
. IBC 906.1/ IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet.
. IBC 1003.2.10 Exit signs are required to be installed per this section
. IBC 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress
are required to have adequate emergency lighting to meet the performance, requirements oflBC
1003.2.11.3. Existing means of egress emergency lighting is permitted to be maintained in compliance
with the code in effect at the time of construction. Any altered path of egress, or new path of egress,
and any new emergency lighting being installed is required to comply with current code requirements.
. 1004.2.3 Egress through intervening spaces. Egress from a room or space shall not pass through
adjoining or intervening rooms or areas, except where such adjoining rooms or areas are accessory to the
area served; are not a high-hazard occupancy; and provide a discernible path of egress travel to an exit.
Egress shall not pass through kitchens, store rooms, closets or spaces used for similar purposes. An exit
access shall not pass though a room that can be locked to prevent egress. Means of egress from dwelling
units or sleeping areas shall not lead through other sleeping areas, toilet rooms or bathrooms. Verify that a
discemible path of egress is maintained through Room # 1 leading to the second exit.
. IBC 1209.1 Provide toilet room floors with smooth, hard, nonabsorbent surface extending minimum 6
inches up onto walls.
. COMM 62.1109 (12) Where counters are provided for sales or distribution of goods or services, at least
one of each type provided shall be accessible.
. IBC 2603.4.1.9 Garage doors. Where garage doors are permitted without a fire resistance rating and foam
plastic is used as a core material, the door facing shall be metal having a minimum thickness of 0.032-inch
(0.8 mm) aluminum or O.OlD-inch (0.25 mm) steel or the facing shall be minimum 0.125-inch-thick (3.2
mm) wood. Garage doors having facings other than those described above shall be tested in accordance
with, and meet the acceptance criteria of, ANSI/DASMA 107. '
. IBC 2902.1/ Table 2902 Drinkingwater is required to be provided, since no drinking fountain is shown
on plans a bottled water cooler is required to be provided.
. Comm 2902 (4) Separate facilities shall not be required in mercantile occupancies in which the occupant
load is 50 or less. Note: if the occupancy changes in the future, the requirements for plumbing fixtures
will need to be reviewed for compliance.
. Comm 61.30(3) / IMC 507.2 This plan review does not include heating, ventilation, or air
conditioning. RV AC plans are required to be submitted and approved prior to installation ofRV AC
equipment. Be aware that mc 1004.3.2.4 contains additional restriction for air movement in corridors
. Comm 16 If the "Car Porter Area" is being used as a wash bay, all wiring will need to be installed in
accordance with code requirement~ for a wet location. Contact Electrical Inspector Kevin Benner for
additional information (920) 236-5046
. Comm 82 If the "Car Porter Area" is being used as a wash bay, there may be additional applicable
plumbing requirements. Contact Plumbing Inspector Paul Wolf for additional information (920) 236':'5052.
I:"Inspedions\Phm Revll;;w\C'nmmen:ial PLm Rt:v.iew 2007\X4-!922-0207 140 KodIer Sf JJkI~, Only. del"
Page 2 of3
. Comm 61.31(4) Revisions to approved plans. AU proposed revisions and modifications which involve
rules under this code and which are made to construction docutr;lents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm 61.31(1).
. MUN 30 This review does not include review for sign age. Applications for and questions regaurding
signage permits should be directed to David Buck - Associate Planner (920) 236-5062.
SUBMIT:
. mc 2902 Table 2902.1 Minimum Number of Plumbing Facilities. A minimum of one service sink is
required to be provided. IMC 403.3 [Comm 64.0403 (6)] Ventilation rate. Janitor closets. A janitor
closet that has only one service sink maybe provided with either natural ventilation via a window or
louvered opening with at least 2 square feet (0.2 m2) of area openable directly to the outside or mechanical
exhaust ventilation as specified in Table 64.0403. Plans submitted do not show the required service sink
included in building plans. Comm 62.2900 (2) requires a service sink to be located in ajanitors closet,
and the IMC requires ventilation of that space. Provide additional details / floor plan showing where
the required service sink will be located and how required ventilation will be provided.
. Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead.
Brian oe
Building Systems Consultant
(920) 236-5051 Monday- Friday 7:30 AM. to 8:30 AM and 12:30 AM to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
Fee Required $
Fee Received $
Balance Due $
320.00
320.00
0.00
]:\Jnspediuns\Pkm Rcvie"y\Ct.\JJlmC1Tial I'lanRevit'W 200TX4-1922.0207 1. 40 Kt.lcHcr $i Bldg Only.dol'
Page 3 of 3