Loading...
HomeMy WebLinkAboutBuilding X4-1908-0207 ~ OJHKOfH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.cLoshkosh.wi.us ON THE WATER February 21,2007 Richard Fisher Fisher & Associates, LLC 642 Tholsen Dr Kimberly, WI 54136 Ron Detj en Landmark LTD III PO Box 2366 Oshkosh, WI 54903 Site: Plan Number: X4-1908-0207 Martial Arts America 300 S Koeller St Suite C-2 Oshkosh WI 54902 For: Description: Tenant space alterations Object Type: Building only Class of Construction: lIB - 1653 Sq Ft.; Sprinklered Occupancy: M: Mercantile I Retail Maximum No of Occupants: 100 The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements NOTE: The unoccupied space that is being provided with a set of doors as per fax received on 2/21/07 is not to be used as an occupied space unless additional plans are submitted for review and approval. Key Item(s) I Conditions: . IBC901.2 Fire protection systems shall be installed, repaired, operated and maintained in accordance with this code and the international fire code. Construction of new walls may require the addition and or relocation of sprinkler heads to maintain required coverage, and not obstruct spray patterns of fire sprinklers. . IBC 906.1 / IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet. . IBC 1003.2.2.5 Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit access doorway from the room or space. Posted signs shall meet the requirement of municipal code section 13-5. Min 12 inches in length, min 4 inches in height with min Yz inch lettering and the numbers being minimum 3 inches in height. The sign shall state "Limit (number) Persons". . IBC 1003.2.10 Exit signs are required to be installed per this section .Re'vje\\'\Co~Dmercial Pltli1 2(i07\X4-190S-{)207 300 5 Kocj)er 51 13kl" Only.do<: Page 1 00 . IBC 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress are required to have adequate emergency lighting to meet the performance requirements of IBC 1003.2.11.3. Provide complete emergency lighting plan showing compliance with these requirements prior to installation of emergency lighting system. Additionally emergency lighting is required to be provided for the new egress path in the unoccupied storage space. . 1004.2.3 Egress through intervening spaces. Egress from a room or space shall not pass through adjoining or intervening rooms or areas, except where such adjoining rooms or areas are accessory to the area served; are not a high-hazard occupancy; and provide a discernible path of egress travel to an exit. Egress shall not pass through kitchens, store rooms, closets or spaces used for similar purposes. An exit access shall not pass though a room that can be locked to prevent egress. Means of egress from dwelling units or sleeping areas shall not lead through other sleeping areas, toilet rooms or bathrooms. Verify that egress path is maintained through the "Preparation Area" . IBC 1004.3.2.1 Construction Corridors (the rear egress path is considered a corridor.) shall be fire- resistance rated in accordance with Table 1004.3.2.1. The corridor walls required to be fire-resistance-rated shall comply with Section 708 for fire partitions. Table 1004.3.2.1 Exception c. Buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2. This will require the monitorin!! and alarms per Section 903.4 this includes ALL valves controllin!! water supplv. . . IBC 2406.2 Glazing in an individual fixed or operable panel adjacent to a door where the nearest exposed edge of the glazing is within a 24 inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface is requires safety glazing materials. . Comm 61.30(3) This review does not include lighting. Corom 63.0001 Prior to installation, lighting plans and calculations shall be prepared in compliance with the code. The plans shall be available upon request. . Comm 61.30(3) / IMC 507.2 This plan review does not include heating, ventilation, or air conditioning. HVAC plans are required to be submitted and approved prior to installation ofHV AC equipment. . Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Cornm 61.31(1). ]:'.!nspediuDs\Pbn .Revil:'w\Commen:ial I'1;m Ro:vit:w 2007\X4-1903-0207 300 S Rodier StBldg Only.do,- Page 2 of3 SUBMIT: . Cornm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. . IBC 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress are required to have adequate emergency lighting to meet the performance requirements of IBC 1003.2.11.3. Provide complete emergency lighting plan showing compliance with these requirements prior to installation of emergency lighting system. . NFP A 72 4.5.2 Provide a copy of the fire alarm system record or completion for the required monitoring and alarms of the automatic fire sprinkler system A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. e Building Systems Consultant (920) 236-5051 Monday- Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 580.00 0.00 580.00 I: \Inspedifms\Phn Rev It'"\.V\C orH'men:~a 1.1> laJl 2007\X4-1 ()(jS-0207 300 S KueHer SI Dldg Only.de)>.: Page3 00