Loading...
HomeMy WebLinkAboutCertificate of Occupancy ~ 4 ..' CITY HALL , Inspection Services Div 215 Church Avenue ~POBOX1130 ~ Oshkosh WI ~ 54903.1130 OfHKOfH ON THE WATER City of Oshkosh Approved: Issued: 02/12/2007 02/13/2007 Associated Bane Corp 206 N Wisconsin DePere WI 54115 CERTIFICATE OF OCCUPANCY An Occupancy Permit is hereby issued for the Associated Bank building located at 10 W Murdock Ave as described in permit #119057. ..j This space is to be used as an office building and is located in the C-2 General Commercial District. LIMITATIONS: Maximum number of persons: 50 Certificate of Occupancy shall be required prior to occupancy, should additional building(s) be erected, or should any buildings mentioned above be altered or moved. The use of land, or buildings, shall not be changed until a Certificate of Occupancy is issued for that occupancy. All conditions noted above must be complied with in order for this certificate to be valid. cc: C R Meyer . Job Address 10 W MUR~OCK AVE Owner ASSOCIATED BANC CORP Building Permit Work Card Permit Number 0119057 Contractor . CR MEYER Create Date 4/20/2006 Category 221 - New Offices, Banks, Professional Plan S5-33-0406 Occupany Permit Required Flood Plain Height Permit Class of Const: VBibc UselNaMe """'. Baok! Doe. s.tOry, 4630 sf, 1170 sf basement, 990 sf drive thru teller canopy.* Notes: No work to. remmeo"" above ."Je of Wo.. rot" Sto"" D..b,ago Plao ;, approved. All ooodl1lo", of Plaoo'o. DM''''' "e,'ow to be met (,ee atta"''''.) HVAC Contr Plumbing Contr Electric Contr Inspections: Date Type Rough In Inspector Allyn Dannhoff Request Line / Ceilings are going up if you want to take a look 8/24/06 - No time - AD no time J DatelTime requested: 8/22/2006 Access: I Requested By: CR MEYER - Chuck o Reinspect Fee 0 Fee Waived 12:49 PM Notice Type: Ready DatelTime: 8/22/2006 12:49 PM =:J Phone Number: (920) 379-5252 D Reinspect Fee Paid Date 9/8/2006 Type Final Request line. 9/8/2006 - See FCN - Final OK - AD Inspector Allyn Dannhoff approved ~ DatelTime requested: 9/1/2006 04:07 AM Notice Type: Ready DatelTime: 9/7/2006 09:30 AM Access: !Brian wants to meet with you on 9/7 for the final. Call if this is not a good time Requested By: CR MEYER - Brian Dobisch Phone Number: 235-3350 o Reinspect Fee 0 Fee Waived D Reinspect Fee Paid ::J Date 2/12/2007 Type Final Inspector Allyn Dannhoff jHV AC . ,mo" de_oo a'a"", and ,"pe",,"" oow '0 pia"". '",e o=p,""" Pe"'" DatelTime requested: Notice Type: Ready DatelTime: Access: I Requested By: Phone Number: o Reinspect Fee 0 Fee Waived D Reinspect Fee Paid approved j ::J Page 2 of 2 Job Address 10' W MUROOCK AVE Owner ASSOCIATED BANe CORP Building Permit Work Card Permit Number 0119057 Contractor CRMl::YER Create Date 4/20/2006 Category 221 - New Offices, Banks, Professional Plan S5-33-0406 Occupany Permit Required Flood Plain Height Permit Class of Const: VBibc Use/Nature New Bankl One story, 4630 sf, 1170 sf basement, 990 sf drive thru teller canopy.. Notes: No work to commence above g.Jrade of Work until Storm Drainage Plan is approved. All conditions of Planning Division Review to be met (see attached.) HV AC Contr Plumbing Contr Electric Contr Inspections: Date 5/1/2006 Type Footings Inspector Allyn Dannhoff REQUEST LINE / WOULD LIKE INSPECTION BY 2 PM MONDAY no time ~ DatelTime requested: 4/28/2006 Access: I Requested By: CR MEYER o Reinspect Fee 0 Fee Waived 11:10AM Notice Type: Ready DatelTime: 4/28/2006 11:10 AM ~ Phone Number: CHUCK 379-5252 D Reinspect Fee Paid Date 5/8/2006 r""da.oo b..emeot~ DatelTime requested: Access: I Requested By: o Reinspect Fee 0 Fee Waived Type Foundation Backfill Inspector Allyn Dannhoff approved j Notice Type: Ready DatelTime: ~ Phone Number: D Reinspect Fee Paid Date 6/29/2006 Type Rough In Inspector Allyn Dannhoff Request line/ready for framing inspection 6/29/2006 - NO TIME - AD no time J DatelTime requested: 6/19/2006 Access: I Requested By: CR MEYER - Chuck o Reinspect Fee 0 Fee Waived 10:53 AM Notice Type: Ready DatelTime: 6/19/2006 10:53 AM =:J Phone Number: D Reinspect Fee Paid Date 7/14/2006 Type Insulation Inspector Allyn Dannhoff equest line / ready for insulation inspection Hurkman-HVAC contractor-Green Bay-Phil (P.Mgr). RI B&H No concerns noted. Spoke to Chuck Mongan about hurricane lips at Drive thru and attic access/compartment details. AD /14/2006 - insulataion OK - AD ~ DatelTime requested: 7/10/2006 08:24 AM Notice Type: Access: Ibuilding open 7am-4pm today Requested By: CR MEYER '- Chuck o Reinspect Fee 0 Fee Waived D Reinspect Fee Paid Ready DatelTime: 7/10/2006 08:24 AM ::J Phone Number: 379-5252 Page 1 of 2 . . Electric Permit Work Card Job Address 10 W MURDOCK AVE Permit Number 120251 Create Oate 6/26/2006 Owner ASSOCIATED BANC CORP Contractor SOLAR ELECTRIC SERVICES INC Category 642 - Commercial-New Building Wiring Service b New o Change 0 Temp . N/A I Type 0 Overhead o Underground . N/A I Volts 120/208 Circuits Luminaires Amps 400 Switches Receptacles Fee $427.00 D Value $80,000.00 Appliances Use/Nature New Bank / One story 4630 sf, 1170 sf basement, 990 sf of drive thru canopy of Work Inspections: Date 09/08/2006 Type Re Final Inspector Kevin Benner approved w/cond. Approved to occupy with the condition that the open wiring issue for the office cubicals would be corrected 1st thing Mon AM 9/11/6. Other vioalations to be corrected ASAP. OatelTime requested: 09/08/2006 11 :00 AM Access: Notice Type: FC Phone Number: Ready OatelTime: 09/08/200602:00 PM Requested by: SOLAR ELECTRIC SERVICES INC Greg C o Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid . Electric Permit Work Card , Job Address 10 W MURDOCK AVE Permit Number 120251 Create Oate 6/26/2006 Owner ASSOCIATED BANC CORP Contractor SOLAR ELECTRIC SERVICES INC Category 642 - Commercial-New Building Wiring Service b New o Change 0 Temp . N/A I Type 0 Overhead o Underground . N/A I Volts 120/208 Circuits Luminaires Amps 400 Switches Receptacles Fee $427.00 D Value $80,000.00 Appliances Use/Nature New Bank / One story 4630 sf, 1170 sf basement, 990 sf of drive thru canopy of Work Inspections: Oate 08/30/2006 Type Abv Ceiling Inspector Kevin Benner not approved Request line 98% of the ceiling tile were installed OatelTime requested: 08/28/2006 06:04 AM Access: Notice Type: Phone Number: 410-5175 Ready OatelTime: 08/29/2006 08:00 AM Requested by: SOLAR ELECTRIC SERVICES INC - Jasor o Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid Oate 09/08/2006 Type Final Inspector Kevin Benner not approved Reviewed vioaltions with the G.C. & E.C. OatelTime requested: 09/06/2006 08:18 AM Access: Notice Type: Phone Number: Ready OatelTime: 09/07/200600:00 AM Requested by: Building Inspector o Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid . Electric Permit Work Card Job Address 10 W MURDOCK AVE Permit Number 120251 Create Oate 6/26/2006 Owner ASSOCIATED BANC CORP Contractor SOLAR ELECTRIC SERVICES INC Category 642 - Commercial-New Building Wiring Service b New o Change 0 Temp . N/A I Type 0 Overhead o Underground . N/A I Volts 120/208 Circuits Luminaires Amps 400 Switches Receptacles Fee $427.00 D Value $80,000.00 Appliances Use/Nature ,New Bank / One story 4630 sf, 1170 sf basement, 990 sf of drive thru canopy of Work t Inspections: Date 07/26/2006 Type Consultation Inspector Kevin Benner not approved Work Space for HVAC equipment Relocate a VFD for the MUA which did not have proper workspace. Reveiwed with Jason & Curtiss from Solar & the HV AC contractor OatelTime requested: 07/26/2006 12:41 PM Access: Notice Type: Phone Number: Ready OatelTime: 07/26/200612:41 PM Requested by: o Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid Oate 08/22/2006 Type Abv Ceiling Inspector Kevin Benner not approved REQUEST LINE / READY FOR THE ABOVE CEILING INSPECTION Not ready & the ceiling installer was starting to install tile Discussed CL2 wiring with Brian Dobish & Chuck (Sup) Discussed Add-A-Depth ring requirements with Jason (Teller Line) OatelTime requested: 08/22/2006 07:47 AM Access: Notice Type: FC Phone Number: (920) 410-5175 Ready OatelTime: 08/22/200608:74 7M Requested by: SOLAR ELECTRIC SERVICES INC-Jason o Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid . Electric Permit Work Card , Job Address 10 W MURDOCK AVE Permit Number 120251 Create Oate 6/26/2006 Owner ASSOCIATED BANC CORP Contractor SOLAR ELECTRIC SERVICES INC Category 642 - Commercial-New Building Wiring Service b New o ChangeO Temp . N/A I Type 0 Overhead o Underground . N/A I Volts 120/208 Circuits Luminaires Amps 400 Switches Receptacles Fee $427.00 D Value $80,000.00 Appliances Use/Nature New Bank / One story 4630 sf, 1170 sf basement, 990 sf of drive thru canopy of Work Inspections: Oate 07/20/2006 Type Service Inspector Kevin Benner not approved Could not open / remove the panel cover OatelTime requested: 07/18/2006 02:52 PM Access: Notice Type: Phone Number: 410-5175 Ready OatelTime: 07/18/200602:52 PM Requested by: SOLAR ELECTRIC SERVICES INC Jason o Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid Oate 07/21/2006 Type Re Service Inspector Kevin Benner approved Faxed to WPS 7/21/6 (& 7/24/6 corrected paperwork) OatelTime requested: 07/21/2006 07:09 AM Notice Type: Phone Number: 410-5175 Access: Jason will be on site until approx. 10:00 AM Ready OatelTime: 07/21/200607:09 AM Requested by: SOLAR ELECTRIC SERVICES INC Jason o Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid , Electric Permit Work Card , Job Address 10 W MURDbcK AVE Permit Number 120251 Create Oate 6/26/2006 Owner ASSOCIATED BANC CORP Contractor SOLAR ELECTRIC SERVICES INC Category 642 - Commercial-New Building Wiring Service p New o Change 0 Temp . N/A I Type 0 Overhead o Underground . N/A I Volts 120/208 Circuits Luminaires Amps 400 Switches Receptacles Fee $427.00 D Value $80,000.00 Appliances Use/Nature New Bank / One story 4630 sf, 1170 sf basement, 990 sf of drive thru canopy of Work Inspections: Oate 07/07/2006 Type Rough In Inspector Kevin Benner approved w/cond. Jason stated that the rough-in is not ready yet, but the G.C. wants to insulate. Installation of the raceways for the walls was 90% complete at the time of inspection. What was installed was okay. No ceiling wiring was installed. OatelTime requested: 07/06/2006 07:30 AM Access: Notice Type: Phone Number: 410-5175 Jason Ready Oate/Time: 07/06/2006 07:30 AM Requested by: SOLAR ELECTRIC SERVICES INC Jason o Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid Oate 07/06/2006 Type Underground Inspector Kevin Benner approved w/cond. Will be trenching (if the trencher works) all day for the parking lot lighting. The trench was dug at the time of inspection only. Curtis stated that 1 "PVC is what would be installed for a wiring method. OatelTime requested: 07/06/2006 03:38 PM Access: Notice Type: Phone Number: Jason-4105175 Ready OatelTime: 07/06/200600:00 AM Requested by: SOLAR ELECTRIC SERVICES INC o Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid . Electric Permit Work Card Job Address ' , Permit Number 120251 Create Date 6/26/2006 10 W MURDOCK AVE Owner ASSOCIATED BANC CORP Contractor SOLAR ELECTRIC SERVICES INC Category 642 - Commercial-New Building Wiring Service b New o Change 0 Temp . N/A I Type 0 Overhead o Underground . N/A I Volts 120/208 Circuits Luminaires Amps 400 Switches Receptacles Fee $427.00 D Value $80,000.00 Appliances Use/Nature New Bank / One story 4630 sf, 1170 sf basement, 990 sf of drive thru canopy of Work Inspections: Date 06/28/2006 Type Underground Inspector Kevin Benner not approved Request linelready for underground inspection. There was not any exposed underground wiring to inspect. Reviewed with Chuck from the G.C., who stated they backfilled and installed the sub-grade immediatey with concerns of rain. Inspection was requested after the installation started. DatelTime requested: 06/27/2006 09:54 AM Access: Notice Type: Phone Number: Jason-410-5175 Ready DatelTime: 06/27/200609:54 AM Requested by: SOLAR ELECTRIC SERVICES INC o Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid Date 06/22/2006 Type Underground Inspector Adam Krause approved Date/Time requested: 06/21/2006 01 :03 PM Access: Notice Type: Phone Number: Ready Date/Time: 06/22/2006 01 :03 PM Requested by: SOLAR ELECTRIC SERVICES INC o Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid HVAC Permit Work Card Job Address 10 W MURDOCK AVE Permit Number 119575 Create Oate 05/17/2006 Owner ASSOCIATED BANC CORP Contractor HURCKMAN MECHAi-JICAL IND., INC. I Category 512 - Ind. & Comm-Both Plan S5-33-0406 Fuel ~ Gas I UOil I ~ Electric I U Solar I U Solid I Value $108,274.00 System o New I D Replace I D Other I ~ Forced Air I ~ Radiant I U Steam I ~ A1C I ~ Vent I U Electric I ~ Hot Water I U Suppl. I U Con. Burner I Chimney Type :0 Chimney A o Chimney B o Direct Vent . Not Applicable I Heat Loss . As Approved o Existing o Not Applicable I Value I BTU Rate . As Per Plan o Variable o Other I Value Use/Nature Comm/ Install radiant hot water in-floor heat with a hot water coil in the air handler. Cooling and fresh of Work air through vav boxes. Condensing unit is remote at grade. Inspections: Oate 7/14/2006 Type Inspector Allyn Dannhoff RI B&H no concerns noted. Spoke to Chuck Mongan about hurricane clips at Drive thru nd attic access/compartment details. AD /14/06 - insulation OK - AD OatelTime requested: Notice Type: Phone Number: Access: ] Ready OatelTime: Requested By: o Reinspect Fee 0 Fee Waived D Reinspect Fee Paid Oate 9/8/2006 Type Final Inspector Allyn Dannhoff approved 9/8/2006 - See FCN - Final OH - AD DatelTime requested: Notice Type: Phone Number: Access: Ready Oate/Time: Requested By: o Reinspect Fee 0 Fee Waived D Reinspect Fee Paid . . Plumbing Permit Work Card Job Address 10 W MURDOCK AVE Permit Number 119545 Create Date 05/17/2006 Owner ASSOCIATED BANC CORP Contractor HURCKMAN MECHANICAL INDUSTRIE~ Category 440 - Industrial-Interior Plan Value $19,200.00 Bathtub Shower Water Softner Wait. St. - Shamp Sink - Coffee Maker - - - - Whirlpool Floor Drain 1 Local Waste Ice Chest - FlrlWst Sink - Int Grease Trap - - - - Lavatory 3 Lndry Tray Clothes Wshr Exam Sink Catch Basin Ext Grease Trap - - - - - Toilet 3 Disposal Bidet Sculry Sink - Wash Ftn - RPZ Valve - - - - Res. Sink Dishwasher Beer Tap Hand Sink Urinal Eye Wash Statn - - - - - - Bar Sink Sump Pump 1 Lab Sink Plaster Sink Standp Rec Wtr Sewer Mtrs - - - - - - Water Heater 1 Classrm Sink Sterilizer Surgeons Sink - Ice Maker - Deduct Meters - - - - Site Drain Breakrm Sink 1 Dip Well F Prep Sink Gar Drain Wtr UsagE! Mtrs - - - - - - Roof Drain Ejector/Grind Drink Ftn 1 Serv Sink ! 1 Soda Disp - - - - - hose bibb ! Misc. 2 - Fixtures Use/Nature Interior plumbing for new Associated Bank. **check #47177 = of Work Size Material Type # Conn.Type Sanitary Sewer Storm Sewer Water Service Date 9/7/2006 Type Final Inspector Paul Wolf approved w/cond. Backflow protection needed at hose bibb near irrigation system water supply. Contacted plumber. DatelTime requested: 9/6/2006 08:56 AM Notice Type: Telephone Number: Access: Ready DatelTime: 9/6/2006 08:56 AM Requested By: HURCKMAN MECHANICAL INDUSTRIES, IN o Reinspect Fee 0 Fee Waived D Reinspect Fee Paid ~ . . Plumbing Permit Work Card Job Address 10 W MURDOCK AVE Permit Number 119545 Create Date 05/17/2006 Owner ASSOCIATED BANC CORP Contractor HURCKMAN MECHANICAL INDUSTRIE~ Category 440 - Industrial-Interior Plan Value $19,200.00 Bathtub Shower Water Softner Wait. St. Shamp Sink Coffee Maker - - - - - - Whirlpool Floor Drain 1 Local Waste Ice Chest Flr/Wst Sink Int Grease Trap - - - - - - Lavatory 3 Lndry Tray Clothes Wshr Exam Sink Catch Basin Ext Grease Trap - - - - - Toilet 3 Disposal Bidet Sculry Sink - Wash Ftn - RPZ Valve - - - - Res. Sink Dishwasher Beer Tap Hand Sink Urinal Eye Wash Statn - - - - - - Bar Sink Sump Pump 1 Lab Sink Plaster Sink Standp Rec Wtr Sewer Mtrs - -----.- - - - - Water Heater 1 Classrm Sink Sterilizer Surgeons Sink Ice Maker Deduct Meters - - - - - - Site Drain Breakrm Sink 1 Dip Well F Prep Sink Gar Drain Wtr Usage Mtrs - - - - - - Roof Drain Ejector/Grind Drink Ftn 1 Serv Sink 1 Soda Disp - - - - - Misc. 2 hose bibb - Fixtures Use/Nature Interior plumbing for new Associated Bank. ..check #47177 ~ of Work Size Material Type # Conn.Type Sanitary Sewer Storm Sewer Water Service Date 7/18/2006 Type Rough In Inspector Paul Wolf not approved 11-1/2" CO ACCESS NEEDED ON LAVATORIES PER COMM 82.35. BACKFLOW PREVENTION NEEDED AT HOSE THREADED CONNECTIONS IN rSEMENT NEAR METER PER COMM 82.41. CAlLED BRUCE AT VIOLATIONS. DatelTime requested: 7/18/200607:42 AM Notice Type: Telephone Number: Access: Ready DatelTime: 7/18/2006 07:42 AM Requested By: HURCKMAN MECHANICAL INDUSTRIES, IN o Reinspect Fee 0 Fee Waived D Reinspect Fee Paid Plumbing Permit Work Card Job Address 10 W MURDOCK AVE Permit Number 119545 Create Date 05/17/2006 Owner ASSOCIATED BANC CORP Contractor HURCKMAN MECHANICAL INDUSTRIE~ Category 440 - Industrial-Interior Plan Value $19,200.00 Bathtub Shower Water Softner Wait. St. Shamp Sink Coffee Maker - - - - - - Whirlpool Floor Drain 1 Local Waste Ice Chest FlrlWst Sink Int Grease Trap - - - - - - Lavatory 3 Lndry Tray Clothes Wshr Exam Sink Catch Basin Ext Grease Trap - - - - - Toilet 3 Disposal Bidet Sculry Sink Wash Ftn RPZ Valve - - - - - - Res. Sink Dishwasher Beer Tap Hand Sink Urinal Eye Wash Statn - - - - - - Bar Sink Sump Pump 1 Lab Sink Plaster Sink Standp Rec Wtr Sewer Mtrs - - - - - - Water Heater 1 Classrm Sink Sterilizer Surgeons Sink Ice Maker Deduct Meters - - - - - - Site Drain Breakrm Sink 1 Dip Well F Prep Sink Gar Drain Wtr Usage Mtrs - - - - - - Roof Drain - Ejector/Gri nd Drink Ftn 1 Serv Sink 1 Soda Disp - - - - Misc. 2 hose bibb - Fixtures Use/Nature Interior plumbing for new Associated Bank. .*check #47177 ~ of Work Size Material Type # Conn. Type Sanitary Sewer Storm Sewer Water Service Date 6/7/2006 Type Underground Inspector Paul Wolf approved Date/Time requested: 6/7/2006 07:23 AM Notice Type: Telephone Number: Access: Ready DatelTime: 6/7/2006 07:23 AM Requested By: HURCKMAN MECHANICAL INDUSTRIES, IN o Reinspect Fee 0 Fee Waived D Reinspect Fee Paid ." "11 commerce.wi.gov ~!!~go"!m~Q Safety and Buildings 4003 N KINNEY COULEE RD LA CROSSE WI 54601-1831 TDD #: (608) 264-8777 www.commerce.wi.gov/sb/ www.wisconsin.gov Jim Doyle, Governor Mary P. Burke, Secretary April 10, 2006 CUST ID No. 622298 A TTN: Buildings & Structures Inspector MIKE DANELSKI ASSOCIATED BANC CORP 206 N WISCONSIN DE PERE WI 54115 BUILDING INSPECTION CITY OF OSHKOSH POB 1130 OSHKOSH WI 54902 REGISTRATION OF COMMERCIAL BUILDING SITE EROSION CONTROL NOTICE OF INTENT SITE: Associated Bank Oshkosh Main & Murdock Sts City of Oshkosh Lot: 2, FOR: Object Type: Soil Erosion Control Regulated Object ID No.: 1070135 Anticipated start date: 04/0112006; Anticipated end date: 08/15/2006; 2 Acres disturbed area This letter acknowledges receipt of a Notice ofIntent with our agency. By virtue of the owner's signature on the application form, he/she has indicated that an erosion control plan and a long-term stormwater management plan meeting the requirements set forth in NR 216.46 and 216.47, respectively have been developed and will be implemented. Please note : 1. That earth disturbing activities shall not begin before 14 days after you submitted the signed Notice of Intent application to our agency. 2. That there will be no review conducted by the Department of Commerce of the erosion control or the gene:ral stormwater management plans for this project. However, plan submittal may be required for any stormwater piping system on the premises and any stormwater infiltration or reuse systems per s. Comm 82.20. 3. That there may be erosion control inspections conducted by the Department of Commerce during the construction of this project. 4. The owner shall retain the above mentioned erosion control stormwatermanagement plan on the construction site and make it available to state and/or local inspectors as requested. 5. That plan review and/or inspections by the local municipality and/ or DNR may be required by local permitting ordinances or DNR rules. 6. The owner shall file a Notice of Termination with our department when the site has been stabilized per NR 216.55. .- .,. ASSOCIATED BANC CORP Page 2 4/1012006 Inquiries concerning this correspondence may be made to Brian Ferris at (608)785-9335, or at the address on this letterhead. Please refer to the Transaction ID No. referred to in the regarding line when making an inquiry or submitting additional information. Sincerely, Jeannie Dixon License/Permit Prog Associate, Integrated Services (715) 634-4870, Fax: (715) 634-5150 7:45 am - 4:30 pm Mon - Fri jeannie.dixon@wisconsin.gov cc: Peter R Ochs, State Building Inspector, (920) 948-3500, Friday, 7:45 A.M. - 4:30 P.M. Mark Dillenburg, Millennium Architects & Designers Ltd ~ ,i" "/I commerce.wi.gov ~i!!a9Jl!Jen Safety and Buildings 2331 SAN LUIS PL STE 150 GREEN BAY WI 54304 TDD #: (608) 264-8777 www.commerce.wi.gov/sb/ www.wisconsin.gov Jim Doyle, Governor Mary P. Burke, Secretary March 14, 2006 CUST ill No. 985854 Fee Required $ Fee Received $ Balance Due $ 800.00 800.00 0.00 PHILLIP BOLENDER MILLENNIUM ARCHITECTS & DESIGNERS 2737 S RIDGE RD STE 100 GREEN BAY WI 54304 REQUEST FOR ADDITIONAL INFORMATION SITE: Associated Bank Oshkosh Main and Murdock City of Oshkosh FOR: Object Type: Building ICC Regulated Object ill No.: 1063544 Major Occupancy: Business; Type VB Combustible Unprotected class of construction; New plan; 6,100 project sq ft; Unsprinklered; Occupancy: B Business, S-1 Storage Moderate-Hazard; Component(s) submitted with this transaction: HV AC ICC; Allowable area determined by: Unseparated Use Object Type: HV AC ICC System Regulated Object ill No.: 1063545 V A V system included; 6,100 sq ft Area Heated The submittal described above has been placed on HOLD and the review and approval is pending subject to receipt ofthe ADDITIONAL INFORMATION and/or revised plans requested by this letter. Upon receipt ofthe additional information and/or revised plans, the plans will be reviewed for compliance to applicable Wisconsin Administrative Codes and Wisconsin Statutes. The following must be corrected/revised and accompany the resubmittal: Key Item(s) . IRC 903.2.12.1 Provide an automatic fire sprinkler system throughout every story or basement where the floor area exceeds 1,500 sf and does not have an appropriate exterior wall opening. Basement area exceeds 1500 sqft., and shall be protected per this code section. Please submit revised plans showing compliance. . IRC 714.2 Provide minimum one-hour rated door assemblies (45 minute or "C" doors are not acceptable) in one-hour rated stairway enclosures. Per Section 714.2.4, they shall meet the positive pressure testing ofNFP A 252 or UL 10C. In non-sprinklered buildings, these PHILLIP BOLENDER Page 2 3/14/2006 doors shall also have a maximum transmitted heat of 450 degrees above ambient after 30 minutes. Doors serving the stair enclosure shall comply with this code section. Please submit revised plans showing compliance. . IBC 716.4 Draft-stopping shall be installed in combustible attics at every 3,000 sf, or in Groups R-I and R-2, the lesser of every 3,000 sf and between every two dwelling units. Area to the east of the north/south draft-stop appears to exceed 3000 sqft. Please submit revised plans showing compliance. Also Address . IECC 803.3.4/Comm 63.1027(2)(a) Reheating, recooling, mixing or other simultaneous operation of heating and cooling systems to the same zone maybe provided if the variable air volume (V A V) systems reduce the air supply to each zone to a minimum before reheating, cooling, or mixing takes place. The minimum volume must be no greater than the largest of the following: (1) 30% ofthe peak supply volume; (2) The minimum required to meet ventilation requirements of Comm 64.0403; or (3) 0.4 cfm/sf of zone conditioned floor area. Submit . Submit, prior to installation, one (1) set of properly signed and sealed precast plans, a completed SB-118 application form including this transaction number and signed by the building designer, and $100 submittal fee to Safety & Buildings, P.O. Box 7162, Madison, WI 53707-7162. Note as per Comm 2.31(1)(d)6. the fee for a structural component erected prior to plan submittal may be an additional $200 Reminders . This review does not include approval or registration for the installation of Boilers and Pressure Vessels indicated on this plan. The installation of any Boiler or Pressure Vessel shall be registered with the Department by the installer before the system is placed in operation as prescribed by COMM 41.41. Registration shall be in writing on Form SBD- 6314. This form, and additional information, maybe obtained via telephone at 608-266-1818 or via the Internet at http://www.commerce.state.wi.us/SB/SB-DivForms.html#Boilers Send your resubmittal into the address listed above, unless otherwise noted, and the department will review the resubmittal within 5 working days of receipt date. Please include a copy of this letter with your resubmittal. If you have any questions, after reading the above comments and related code sections cited, please call me at the telephone number below. Ifthe above requested information and/or plans are not received within 30 business days of the date of this correspondence, this submittal will be returned denied. No fees will be refunded, and a new fee, application form, and submittal of plans/specifications will be required should you desire to continue with this project. The code in effect at the time of new submittal would apply. PHILLIP BOLENDER Page 3 3/14/2006 Sincerely, John J W otruba Plan Reviewer, Integrated Services (920)492-6500, 7:45 am - 4:30PM j ack.wotruba@wisconsin.gov cc: Peter R Ochs, State Building Inspector, (920) 948-3500 , Friday, 7:45 A.M. - 4:30 P.M. Phil Steinhofer, Hurckman Mechanical Inc Jon P Wolf, Boiler Inspector, (920) 723-0032 "Ii commerce.wi.gov ~1!~gJ)!Jen Safety and Buildings 2331 SAN LUIS PL STE 150 GREEN BAY WI 54304 TDD #: (608) 264-8777 www.commerce.wi.gov/sb/ www.wisconsin.gov Jim Doyle, Governor Mary P. Burke, Secretary March 29,2006 CUST ill No. 985854 ATTN: Buildings & Structures Inspector PHILLIP BOLENDER MILLENNIUM ARCHITECTS & DESIGNERS 2737 S RIDGE RD STE 100 GREEN BAY WI 54304 CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 03/29/2008 BUILDING INSPECTION CITY OF OSHKOSH POB 1130 OSHKOSH WI 54902 SITE: Associated Bank Oshkosh Main and Murdock City of Oshkosh FOR: Object Type: Building ICC Regulated Object ill No.: 1063544 Major Occupancy: Business; Type VB Combustible Unprotected class of construction; New plan; 6,100 project sq ft; Unsprinklered; Occupancy: B Business, S-l Storage Moderate-Hazard; Component(s) submitted with this transaction: HV AC ICC; Allowable area determined by: Unseparated Use Object Type: HV AC ICC System Regulated Object ill No.: 1063545 V A V system included; 6,100 sq ft Area Heated The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. The following conditions shall be met during construction or installation and prior to occupan~y or use: Submit . Submit, prior to installation, one (1) set of properly signed and sealed precast plans, a completed SB-118 application form including this transaction number and signed by the building designer, and $100 submittal fee to Safety & Buildings, P.O. Box 7162, Madison, WI 53707-7162. Note as per Comm 2.31(1)(d)6. the fee for a structural component erected prior to plan submittal may be an additional $200 . Submit, prior to installation, one (1) set of properly signed and sealed truss plans, a completed SB-118 application form including this transaction number and signed by the building designer, and $100 submittal fee to Safety & Buildings, P.O. Box 7162, Madison WI PHILLIP BOLENDER Page 2 3/29/2006 53707-7162. Note as per Comm 2.31(1)(d)6. the fee for a structural component erected prior to plan submittal may be an additional $200 Reminders . This review does not include approval or registration for the installation of Boilers and Pressure Vessels indicated on this plan. The installation of any Boiler or Pressure Vessel shall be registered with the Department by the installer before the system is placed in operation as prescribed by COMM 41.41. Registration shall be in writing on Form SBD- 6314. This form, and additional information, maybe obtained via telephone at 608-266-1818 or via the Internet at http://www.commerce.state.wi.us/SB/SB-DivForms.html#Boilers A copy of the approved plans, specifications and this letter shall be on-site during construction and open to inspection by authorized representatives of the Department, which may include local inspectors. If plan index sheets were submitted in lieu of additional full plansets, a copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file with the Department. All permits required by the state or the local municipality shall be obtained prior to commencement of construction/installation/operation. If this construction project will disturb one or more acres ofland, an Erosion Control Notice of Intent (NO!) shall be filed with the department 14 days prior to any earth disturbing activities. In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Sincerely, Fee Required $ Fee Received $ Balance Due $ 950.00 950.00 0.00 John J W otruba Plan Reviewer, Integrated Services (920)492-6500 , 7:45 am - 4:30PM jack.wotruba@wisconsin.gov cc: Peter R Ochs, State Building Inspector, (920) 948-3500 , Friday, 7:45 A.M. - 4:30 P.M. Associated Bank Phil Steinhofer, Hurckman Mechanical Inc Jon P Wolf, Boiler Inspector, (920) 723-0032 ..j. commerce.wi.gov "'U;,{ i!E.9n!ln Safety and Buildings 2331 SAN LUIS PL STE 150 GREEN SAY WI 54304 TDD #: (608) 264-8777 www.commerce.wi.gov/sb/ www.wisconsin.gov Jim Dc)y1e, Governor Mary P. Burke, Secretary June 27, 2006 CUST ID No. 985854 ATTN.' Buildings & Structures Inspector PHILLIP BOLENDER MILLENNIUM ARCHITECTS & DESIGNERS 2737 S RIDGE RD STE 100 GREEN BAY WI 54304 BUILDING INSPECTION CITY OF OSHKOSH POB 1130 OSHKOSH WI 54902 COMPONENT RECEIVED SITE: Associated Bank Oshkosh Main & Murdock Sts City of Oshkosh Lot: 2, FOR: Object Type: Precast Plank Regulated Object ID No.: 1083867 The department has received the above component plan indicated as being reviewed for compliance with the general design concept and submitted by the building designer named above. The Department has filed the plans and other related documents. The department will rely on, and hold responsible, the building design professional and/or supervising professional of record for compliance with the rules. The responsible professional should particularly insure that proper loads and fIre resistive rating have been incoIporated to correspond to the building design. Particularly insure: proper dead and live loading, including snow drift loading increases, unbalanced loads, equipment loads, proper bearing/supports, concentrated loads etc, are properly conveyed to foundations; and that required fIre ratings have been employed. The submitted materials have not been reviewed by the Department for compliance with all applicable administrative rules. The department reserves the right to formally review the plans in the future if the department determines that such a review is warranted, and to order corrective actions with respect to the outcome of that review. A copy of the plan that is identical to the plan submitted for our file shall be available for inspection at the job site. When the total building volume exceeds 50,000 cubic feet, the plan shall bear an indication of review that has been signed or initialed by the building designer of record. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Please refer to Transaction In No. referred to in the regarding line when making an inquiry or submitting additional information. Sincerely, Fee Required $ Fee Received $ Balance Due $ 100.00 100.00 0.00 Anna Beck License/Perrnit Prog Associate, Integrated Services (920) 492-5601, Fax: (920) 492-5604 , Tuesday - Friday 8 am - 4:30 pm anna.beck@wisconsin.gov cc: Peter R Ochs, State Building Inspector, (920) 948-3500, Friday, 7:45 A.M. - 4:30 P.M. ........~ commerce.wi.gov ~i!~9Jl!JJJ Safety and Buildings 2331 SAN LUIS PL STE 150 GREEN SAY WI 54304 TOO #: (608) 264-8777 www.commerce.wi.gov/sb/ www.wisconsin.gov Jim Doyle, Governor Mary P. Burke, Secretary June 27, 2006 CUST ill No. 985854 ATTN.' Buildings & Structures Inspector PHILLIP BOLENDER MILLENNIUM ARCHITECTS & DESIGNERS 2737 S RIDGE RD STE 100 GREEN BAY WI 54304 BUILDING INSPECTION CITY OF OSHKOSH POB 1130 OSHKOSH WI 54902 COMPONENT RECEIVED SITE: Associated Bank Oshkosh Main & Murdock Sts City of Oshkosh Lot: 2, FOR: Object Type: Truss, Roof Regulated Object ill No.: 1083873 The department has received the above component plan indicated as being reviewed for compliance with the general design concept and submitted by the building designer named above. The Department has filed the plans and other related documents. The department will rely on, and hold responsible, the building design professional and/or supervising professional of record for compliance with the rules. The responsible professional should particularly insure that proper loads and fIre resistive rating have been incorporated to correspond to the building design. Particularly insure: proper dead and live loading, including snow drift loading increases, unbalanced loads, equipment loads, proper bearing/supports, concentrated loads etc, are properly conveyed to foundations; and that required fIre ratings have been employed. The submitted materials have not been reviewed by the Department for compliance with all applicable administrative rules. The department reserves the right to formally review the plans in the future if the department determines that such a review is warranted, and to order corrective actions with respect to the outcome of that review. A copy of the plan that is identical to the plan submitted for our file shall be available for inspection at the job site. When the total building volume exceeds 50,000 cubic feet, the plan shall bear an indication of review that has been signed or initialed by the building designer of record. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Please refer to Transaction ID No. referred to in the regarding line when making an inquiry or submitting additional information. . In general ALL component plans should be sent to the Madison offIce, P.O. Box 7162 Madison 53707-7162 for processing, unless specifIcally indicated otherwise on the building plan review letter. Sincerely, Fee Required $ Fee Received $ Balance Due $ 100.00 100.00 0.00 Anna Beck LicenselPermit Prog Associate, Integrated Services (920) 492-5601, Fax: (920) 492-5604, Tuesday - Friday 8 am - 4:30 pm anna.beck@wisconsin.gov cc: Peter R Ochs, State Building Inspector, (920) 948-3500 , Friday, 7:45 A.M. - 4:30 P.M. DEPARTMENT OF PUBLIC WORKS 215 Church Avenue P.O. Box 1130 Oshkosh, Wisconsin 54903-1130 Ph. (920) 236-5065 Fax (920) 236-5068 ~ OJHKOJH ON THE WATER E' r C May 15,2006 MAY 1 6 2006 Mr. Mark Dillenburg Millennium Architecture 2737 S. Ridge Road Suite 100 Green Bay, WI 54304 DEPAHTMENT.OF COMlvlUNFfV DEVELOPMENT RE: Drainage, Grading and Erosion Control Plan Approval (10 W. Murdock Ave) Dear Mr. Dillenburg: This letter is to inform you that the Drainage, Grading and Erosion Control Plans (dated May 2, 2006), which you submitted on behalf of Associated Bank, have been reviewed and approved. The Storm Water Management Plan was previously approved (April 27, 2006). If you have any further questions regarding this project, please do not hesitate to contact us. James Rabe, P .E. Civil Engineer I cc: David Patek, P .E., Director of Public Works Steve Gohde, P.E., Assistant Director of Public Works Ed Potempa, P .E., Civil Engineer II [..A1~ Dannhoff, Director of Inspection Services David Buck, Zoning Administrator / Associate Planner Brian Noe, Building Systems Inspector File I:\Engineering\SWMP - (Non-residential)\l 0 W. Murdock Ave - Associated Bank\Drainage Grading and Erosion Control Plan Approval.doc Page 1 of 1 ~ City of Oshkosh Inspection Services Division 215 Church Avenue, PO Box 1130 Oshkosh, WI 54903-1130 Phone: (920) 236-5050 Fax (920) 236-5084 JOB LOCATION: CONTRACTOR: PROJECT TO BE INSPECTED: f\.L TYPE OF INSPECTION: p-"","..j ~ CORRECTION NOTICE / FIELD INSPECTION REPORT Violations must be corrected and approved within 30 days unless otherwise noted. Call for re-inspections prior to concealment and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of .CO])E INSPECTION RESULl'S -p: . s- Print Name Company Signature: Date Buildings, HV AC, Compliance Statement This form is required to be submitted by the supervising professional (architect, engineer, HVAC designer or electrical designer) observing construction of projects within buildings with total areas 50,000 cubic feet or greater and bleachers ;Comm 50.10/Comm 61.50). Failure to submit this form may result in penalties as specified in Comm 50.26/Comm 61.23 and/or local ordinances. General Instructions: Prior to the initial occupancy of new buildings or additions and the final occupancy of altered existing buildings, submit this completed and signed form to: · The municipal building inspection office and · Safety and Buildings, 10541 N Ranch Road Hayward. Wi. 54843 Personal information you provide may be used for secondary purposes [Privacy Law, s. 15.04 (1 )(m)]. 1. PROJECT INFORMATION: Please fill in the following with information from your plan approval letter. Transaction ID Number 12-452<'1 Site Number 70 t:t8z.. ~ Site location (number & street) H e'l I~ ~ n..,t I~ \,) r J oe 1<::- ~ City 0 Village 0 Town of (Js\-t'\LoS\'t County of 2. PURPOSE OF THIS STATEMENT: (Check Box A, B, C, or 0 to indicate purpose and complete any other applicable boxes and information. Attach additional pages if necessary.) Check those which apply: )isuilding Object 10 # loIf35~.tf 0 HVAC Object 10 # o Lighting Object 10 # o Partial Completion A) 'f Description of Portion Completed Statement of Substantial Compliance To the best of my knowledge, belief, and based on onsite observation, construction of the following building and/or HVAC items applicable to this project have been completed in substantial compliance with the approved plans and specifications. o BUILDING/LIGHTING ITEMS 1. Structural system including submittal and erection of all building components (trusses, precast, metal building, etc.) 2. Fire protection systems (sprinklers, alarms. smoke detectors) designed, installed, and tested Oncluding forward flow on back flow devices) by appropriately registered profeSSionals 3. Shaft and stairway enclosure 4. Exits including exit and directional lights 5. Fire-resistive construction, enclosure of hazards, fire walls, labeled doors. class of construction, fire stopped penetrations 6. Sanitation system (toilets, sinks, drinking facilities) 7. Barrier-free including Comm 18 elevators and lifts 8. Energy envelope requirements 9. All conditions of building plan approval and applicable variances The following items are not in compliance and must be addressed: 10. Exterior lighting & control requirements 11. Interior lighting & control requirements 12. All conditions of lighting plan approval and applicable variances o HVACITEMS 1. HV AC system including final test 2. All conditions of HVAC plan approval and applicable variances B) 0 Statement of Noncompliance Due to the following listed violations. this project is not ready for occupancy: C) 0 Supervising Professional Withdrawn From Project D) 0 Project Abandoned 3. SUPERVISING PROFESSIONAL SIGN Jf Building 0 HVAC 0 Lighting Signature , SBD-9720 (R.OII2002) 23 09/12/200811,:42 FAX 8204883758 HURCKMAN MECH ~ 0021002 '.. I , .\ .; BUILDINGS, HV AC, COMPLIANCE STATEMENT SBD-9120 This fonn is required to be submitted by the supervising professional (architect, engineer, HVAC designer or electrical designer) Ob8e1Ving construction of projeCIB within buikfl~ \Mth total areas 50.000 cubic feet or greater and bleachers (Comm 5O.101C0mm 61.50). Failure to submit this form may result In penalties a6 specified in Comm SO.26K;omrn 61.23 and/or local ordinances. Thill turn must be submitted prior to the plan approval explratlon date or another tubmlUal may be fflquit8d. Genenallmdrudlons: Prior to the initial occupancy of new buildings or additions and the 1Inal occupancy of altered uisting buildings, submit this completed and signed rorm to: . The munldpll bulldlnglnapectlOn offtCe (refer to the plan approval....., for agency addrns JmI · Safety and Butldlng.. 10541N Rand! Road Hayward, Wi. 54M3 No!e: tf the reYi.. was done by the rnunicipl!lllty, the compliance $tatement gee. only to the municipal building inspector. A copy is not needed by Safety & Buildings. PIt,.".1 information JlOU ~ ...y be u_d tor lI8CIDhdery pur'pl)eM [Privacy lAw, 8. 15.04 (1 )(m)]. 1. PROJECT INFORMA noN; Please 111I In the following with Information from your p1Bn ii1pprovalletter. T,......ctlon 10 Number I '}...':f S'Ltt I Project Name J1-c;soe,,~~ ~ /~ c:u~J-f,Q? s H Site Number 70Cf P .)..g Site location (number & Itreet) MA-Iw ~A A1uA..LloL4C uT'Clty 0 VAlage 0 Town Of (25J.pfrd~J.I County of WIIVA/~O 2. PURPOSE OF THIS 8TA TEMENT: (Check Box A, e. C, or 0 to Inclcate p1JfPO" and complete any other applcabll! boxes and Information. Attach additional pages If necessary.) Check 1tJose which apply: C Building Object ID ,. ~HVAC Object JO'" I Ole. 351.fS" o lighting Object ID ## t 1 l f Cl Partial Completion o-..it-Ln of Partion ComplDd . A) It St.Glbtrnent t1I SUblllllntial Compllanee To the bRt or my knowtedge. belief. tnd baed on on&iIa obNlYWtian. cona1ndon of the foOcMing buildi"g .ndIor HVAC lt8ma .ppllc:abte ID tIlll!l projlct hIlw been complltBd In ..betanti<<1 COmpftancl wfth .. lIppr1Jwd plana anet ~tion.. o aUIlDINGIlIOHTlNG ITEM. 1. 8Iruc$nI.-.n IneludIIl9 ellbmllllllenll .,.ctJon of.. bYIIdlr\g ~ ~ ~ .....11ddIIlg. ek) 2. FIN plUtilaIon synama ~.lIIarms, emoa cMIl1OlDt8) de_ned, 1nltlIIecI, efld..... (IrIctqdIng ............,"" ~ .,.,........) byNPf'OprlOIIy IIlgIIterM profM&Ionell 3. 6fl1lft IInd -"-1 endo_ ... Exb ~g eJdl and clit9dIoNl ..... ~ F~ GOIISWUdton. _leisure of h__, lite -'Is. ..bMtd doof'll. 01_ uf IIDrIlIlnIdlan, tn W>>pped ,...........I<h. e. s.nbIIlln.-m (tD...., lIInIaI. drHdng faollllel) 'T. !ll1Iiw-Jlw ~. Comm ,.......... IInd IIftt .. EMrrw -lope Nqunm.nIll 8. Nll'OIIdIIIona of bulcfng plan IIppnMlland applicable vwrIallC8l1 lbe1bl1owlntl ...... .,. nGt In ~ and muat be add.-..d: 10. ExtMor 1IgfIII"Il .. IID.-I *Iu1remM1ta 11. IntIIrlDf""""''' CIlIfthf ,..,""** 12. AI condlIonll of IIghtlno plan lIppnl'I.r Rnd ~1lIe ..,.,_ f r 'J( tNAC I1EMS 1. HVAC .,..,m InducIIng tInIIllMt 2. AIIIlD/IdlIIaftI of HVAc pion .,ptll1llll end IIpp/1ea1l1e WfIenoe. B) C Stafllment 01 Nonc:ompUance Due 10 Ihe foIIDwIng ..... ~ this projeGt . not _cfy ..r OClllU~ncy: I C) tJ Supervising Pror..... WithdrllWft From PrOjflct (Use A or 8 u-e !a Indicallt JIIO.Ieat S1IIIUII as oflhl& date.) 0) D project Abandoned 3. SUPeRVISING PROFESSIONAL SIGNATURE FOR: C Building )l...HVN; C LIghIng fJUIL S~....IA.lHO~ 0.. st-~ ......._9_-'711-=::"'9:;;;:-'2. _ P,&"'I'SL-~ ! I t I t SB1>9i'2O lJUW20OS) ----,---... Page 1 of1 Dannhoff, Allyn J. From: Phil Steinhofer [philsteinhofer@hurckman.com] Sent: Friday, January 26,20078:41 AM To: BDobish@crmeyer.com Cc: adannhoff@cLoshkosh.wLus Subject: FW: Associated Bank - Oshkosh -----Original Message----- From: Ray Olson [mailto:rayolson@contechnetwork.net] Sent: Thursday, January 25, 2007 2:39 PM To: philsteinhofer@hurckman.com Subject: Associated Bank - Oshkosh Phil, The smoke detector enunciator for the Associated Bank - Oshkosh location has been installed and tested. Thanks, ~ Ray Ray Olson Senior VP ConTech NetWork Inc. 1457 Donald St. Green Bay, WI 54303 920-497-0306 I r::l . I E-MAIL NOTICE: The information contained in this electronic mail message [and all attachments thereto] is intended for the personal and confidential use of the designated recipient(s). If the reader of this message is NOT the intended recipient or an agent authorized to receive personal and confidential messages directed to the intended recipient(s), you are hereby notified that you have received this message in error, and that any review, dissemination, distribution, copying or any other use of this message is strictly prohibited. 1/26/2007 Page 1 of 1 Dannhoff, Allyn J. From: Brian Dobish [BDobish@crmeyer.com] Sent: Wednesday, January 10, 20074:17 AM To: 'Dannhoff, Allyn J.' Cc: 'philsteinhofer@hurckman.com' Subject: FW: Associated Bank - Oshkosh, WI . . Allyn: Attached is additional info from Hurckman for Associated Bank. I would assume this fixture would replace the existing fixture located behind the teller line to provide the required notification. Let us know if this will be acceptable. Thanks, Brian From: Phil Steinhofer [mailto:philsteinhofer@hurckman.com) Sent: Tuesday, January 09, 2007 4:40 PM To: Brian Dobish Cc: adannhoff@ci.oshkosh.wLus Subject: FW: Associated Bank - Oshkosh, WI 1/10/2007 RE: Associated Bank - Oshkosh, WI Page 1 of3 . I ~ .. Dannhoff, Allyn J. From: BDobish@crmeyer.com Sent: Wednesday, January 10, 20074:18 AM Brian, Attached is the response from Ray Olson with Con tech Network. They will add the control noted in Ray's email to me. If you have any questions, please call. Phil Steinhofer -----Original Message----- From: Ray Olson [mailto:rayolson@contechnetwork.net] Sent: Tuesday, January 09, 2007 2:00 PM To: philsteinhofer@hurckman.com Subject: RE: Associated Bank - Oshkosh, WI Phil, We ordered a MSR-100RlW (see attached document) indicator/control assy. I can have AI replace the existing one when we receive the new. This will provide an audible and visual indication if smoke or trouble with the smoke detector occurs. I'll let you know when this is complete. Thanks, Ray Ray Olson Senior VP ConTech Network Inc. 1457 Donald 8t. Green Bay, WI 54303 920-497-0306 ICl E-MAIL NOTICE: The infol1nationcontained in this electronicmaiI message [and all attachments thereto] is intended for the personal and cont,dential use of the designated recipient(s). If the reader of this message is NOT the intended recipient or an agent authorized to receive personal and confidential messages directed to the intended reeipient(s), you are hereby notified that you have received this message in error, and that any review, dissemination, distribution, copying or any other use of this message is strictly prohibited. From: Phil Steinhofer [mailto:philsteinhofer@hurckman.com] Sent: Tuesday, January 09, 2007 11:12 AM To: rayolson@contechnetwork.net Subject: FW: Associated Bank - Oshkosh, WI Raymond, Do you have an answer for the attached? Advise. Phil -----Original Message----- From: Dannhoff, Allyn J. [mailto:adannhoff@ci.oshkosh.wLus] 1/10/2007 RE: Associated Bank - Oshkosh, WI Page 2 of3 . t t ... Sent: Tuesday, January 09, 2007 9:26 AM To: 'Brian Dobish'; Dannhoff, Allyn J. Cc: 'philsteinhofer@hurckman.com' Subject: RE: Associated Bank - Oshkosh, WI Gentlemen; Thank you for the response. Per 606.4.1 Supervision, exception #2 you have described how the fIrst part is being satisfied. The question I still have is how is the second sentence of this code section being satisfIed? In short, if the smoke detectors malfunction (trouble condition) how is the required signal being provided, where is it being provided (must be in a location that will be noticed) and how is it being identified as a trouble signal? Thank you. Allyn Dannhoff Director of Inspection Services -----Original Message----- From: Brian Dobish [millJtQ:BI!QPli;h@CJIl1.J;Y~r,cQ..m] Sent: Tuesday, January 09, 2007 9: 11 AM To: 'Dannhoff, Allyn J.' Cc: 'philsteinhofer@hurckman.com' Subject: FW: Associated Bank - Oshkosh, WI -----Original Message----- From: Phil Steinhofer Lm?i1.tQ;phjl~JGj!1llQfGI@h!lrckm~n,GQJn] Sent: Tuesday, January 09, 2007 8:43 AM To: Brian Dobish Subject: Associated Bank - Oshkosh, WI Brian, The operating sequence and parts numbers are as follows: If smoke is detected, the Air Products and Controls, Inc. #SM50 1- N smoke detector, located inthe return air duct of Air Handler #1, closes contacts generating an alarm condition shutting down AHU #1 and sends alarm to Air Products and Controls, Inc. #MS-RHIPIA 78db remote alarm horn and LED red alarm light located n the Lobby Room 101 near the teller area vor visual and audible alarm in an occupied area. The alarm is sent to the DDC HV AC control system locking out the air handler until the alarm is cleared. The wiring diagram for the smoke detection system is also located in the Operation and Maintenance Manual located on the jobsite. The Air Products and Controls, Inc. smoke detector and alarm are UL listed, CSMF listed and MEA approved. 1/10/2007 RE: Associated Bank - Oshkosh, WI Page 3 of3 .. '.t' ~ If you have any questions, please call. Phil Steinhofer Phil Steinhofer Hurckman Mechanical Industries, Inc. Phone (920) 499-6984 x116 Fax (920) 499-3758 philsteinhofer@hurckman.com www.hurckman.com E-MAIL NOTICE: The information contained in this electronic mail message [and all attachments thereto] is intended for the personal and confidential use of the designated recipient(s). If the reader of this message is NOT the intended recipient or an agent authorized to receive personal and confidential messages directed to the intended recipient(s), you are hereby notifIed that you have received this message in error, and that any review, dissemination, distribution, copying or any other use of this message is strictly prohibited. NOD32 1967 (20070109) Information This message was checked by NOD32 antivirus system. bJl.pJl:WYY_W,~s~tG_Qm 1/1 0/2007 MSR-100RIW CSFM USTED c us UITED MEA ACC,EPTED PRODUCT DESCRIPTION: The MSR Series remote accessories are designed to be used with Air Products and Controls Duct Smoke Detectors to provide the most complete functionality ever available in such a device. The remote accessory is available with either the single gang remote indicator/control (MSR-100R Products), or with the addition of a single gang strobe assembly (MSR-100S Products). Both versions are compatible with standard architectural (decora) style cover plates (choice of white, red or stainless steel). The indicator/control assembly provides: . Visual indication of detector Pilot, Trouble and Alarm Functions . Selectable audible indication of Alarm, Trouble or both . Buzzer Silence function, with silenced indication and "ring back" following condition correction . Lamp/Buzzer test function . Key-Operated detector Test and Reset functions . Lever-operated "No-Tools" terminal block . Port for plugging in the optional strobe assembly . Black "DUCT SMOKE DETECTOR" decal included for front plate . Blue "SMOKE", red "FIRE" strobe lens decals included for both horizontal and vertical mounting Copyright @ 2005 Air Products and Controls Inc. ~A;~ HALMA GROUP