HomeMy WebLinkAboutBuilding X4-1905-0207 ~ OJHKOJH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.cLoshkosh.wi.us ON THE WATER February 13,2007 Kenneth Van Tine Van Tine Guthrie Studio 114 E. Main St Northville, MI 48167 Jeff Doligate Verizon Wireless 1515 E Woodfield Schamnburg, IL 60173 Andy Dumke River Valley One LLC 222 Ohio St Oshkosh WI 54902 Site: Plan Number: X4-1905-0207 Verizon Wireless 550 S Koeller St Oshkosh WI 54902 For: Description: Tenant space alterations Object Type: Building only . Class of Construction: VB - 2854 Sq Ft.; Sprinklered Occupancy: M: Mercantile I Retail MaximmnNo of Occupants: 71 The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) I Conditions: . mc 901.2 Fire protection systems shall be installed, repaired, operated and maintained in accordance with this code and the international fIre code. Construction ofnew walls may require the addition and or relocation of sprinkler heads to maintain required coverage, and not obstruct spray patterns of fire sprinklers . NFP A 13-3-2.6.3.4 Ornamental fInishes shall not be applied to sprinklers by anyone other than the sprinkler manufacture, and only sprinklers listed with such fmishes shall be used. Sheet A-5 indicates that sprinkler heads in soffits are to be painted to match - verify that sprinkler m.anufacture has applied an approved finish per the listing. . mc 1003.2.10 Exit signs are required to be instaJled per this section . me 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress through The Retail Display area are required to have adequate emergency lighting to meet the performance requirements ofIBC 1003.2.11.3. Provide complete emergency lighting plan showing compliance with these requirements prior to installation ofemergency lighting system. \\SNAPMIS03\USERS\bn,-!lm\2007 Conu11 Plan Re\"1ews\X4-! 905..0207 550 S Ko"Uer Si Bldg Only.dol: Page 1 of4 · IBC 1008.1.3.4 Access-controlled egress doors. The entrance doors in a means of egres~ in buildings with an occupancy in Group A, B, E, M, R-l or R-2 and entrance doors to tenant spaces in occupancies in Groups A, B, E, M, R-1 and R-2 are permitted to be equipped with an approved entrance and egress access control system which shall be installed - in, accordance with all of the following criteria: 1. A sensor shall be provided on the egress side arranged to detect an occupant approaching the doors. The doors shall be arranged to unlock by a signal from or loss of power to the sensor. J 2. Loss of power to that part of the access control system which locks the doors shall automatically unlock the doors. 3 The doors shall be arranged to unlock from a manual unlocking device located 40 inches (1016 mm) to 48 inches (1219 mm) vertically above the floor and within 5 feet (1524 mm) of the secured doors. Ready access shall be provided to the manual unlocking device and the deVice shall be clearly identified by a sign. When operated, the manual unlocking device shall result in direct interruption of power to the lock~independent of the access control system electronic~and the doors shall remain unlocked for a minimum of 30 seconds. 4. Activation of the building fire alarm system, if provided, shall automatically unlock the doors, and the doors shall remain unlocked until the fIre alarm system has been reset. 5. Activation of the building automatic sprinkler or fIre detection system, if provided, shall automatically unlock the doors. The doors shall remain unlocked until the fIre alarm system has been reset. 6. Entrance doors in buildings with an occupancy in Group A, B, E or M shall not be secured from the egress side during periods that the building is open tothe general public. Verify that security controls / door hardware is installed in compliance with these requirements. · IBe 1003.3~1.8.2 Delayed egress locks. Approved, listed, delayed egress locks shall be permitted to be installed on doors serving any occupancy except Group A, E and H occupancies in buildings which are equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or an approved automatic smoke or heat detection system installed in accordance with Section 907, provided that _the doors unlock in accordance with Items I through 6 below. A building occupant shall not be required to pass through more than one door equipped with a delayed egress lock before entering an exit. 1. The doors unlock upon actuation of the automatic sprinkler system or automatic fIre detection system. 2. The doors unlock upon loss of power controlling the lock or lock mechanism. 3. -The door locks shall have the capability of being unlocked by a signal from the fIre command center. 4. The initiation ofan irreversible process which will release the latch in not more than 15 seconds when a force of not more than 15 pounds (67 N)is applied for 1 second to the release device. Initiation of the irreversible process shall activate an audible signal in the vicinity of the door. Once the door lock has been released by the application of force to the releasing device~ relocking shall be by manual means only. Exception: Where approved, a delay of not more than 30 seconds is permitted. . 5. A sign shall be provided on the door located above and within 12 inches (305 mm) of the release device reading: PUSH UNTIL ALARM SOUNDS. DOOR CAN BE OPENED IN 15 SECONDS. 6. Emergency lighting shall be provided at the door. Sheet SEC-l indicates that the power loss fail condition is to "fail secure" - this would not comply with the above requirements Verify that security controls/doqr hardware is installed in compliance with these requirements. \\SNAPMJ$03\USERS\briiilln\2007 Comm Plan Re\'iews\X4-i905~1}207 550 S KodJer Si nUg Only.doL' Page 2 of 4 · IBC 1209.1 Provide toilet room floors with smooth, hard, nonabsorbent surface extending minimum 6 inches up onto walls. Sheet A5 indicates that 4 inch base bd. is being installed in toilet rooms -please change. to required 6 inch base bd. · IMC 602.2.1 Materials exposed within plenums. Except as required by Sections 602.2.1.1 through 602.2.1.4, materials exposed within plenums shall be noncombustible or shall have a flame spread index of notmore than 25 and a smoke-developed index of not more than 50 when tested in accordance with ASTM E 84. · NEC 400.8 Flexible cords shall not be used as a substitute for fIxed wiring of a structure. Sheet E-l shows SJO cord being used to wire curved display. - Contact Electrical Inspector - Kevin Benner (920) 235-5046 to review and discuss this issue · NEC 600.3 Electric signs and outline lighting - fIxed, mobile, or portable - shall be listed and installed in conformance with that listing. Sheet A-4 shows a "recessed Ughtbox" which may be considered a sign - Contact Electrical Inspector - Kevin Benner (920) 235-5046 to review and discuss this issue · COIllm 61.30(3) This review does not include lighting. Comm63.0001 Prior to installation, lighting plans and calculations shall be prepared in compliance with the code. Submit energy worksheets for lighting - Section3. can be downloaded at http://commerce.wi.gov/SBdocs/SB- CommBldgEner\Vrkshts.pd:f: · Comm 61.30(3) I IMC 507.2 TJiis plan review does not include heating, ventilation, or air conditioning. HV AC plans are required to be submitted and aprroved prior to installation ofHV AC equipment. - · COp:lm '61.31(4) Revisions to approved plans. All proposed revisions and modifIcations which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office; that granted the approval. All revisions and modifIcations to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modifIcation being carried out. A revision or modifIcation to a plan, drawing or specifIcation shall be signed and sealed in accordance with Comm 61.31(1). · MUN 30 This review does not include review for sign age. Applications for and questions regarding signage permits should be directed to Todd Muehrer - Associate Planner (920) 236-5057. · MUN 30-35 (1)(5) All roof top and ground level mechanical equipment and utilities shall be fully screened from view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236- 5062 for additional information on screening requirements. All screening shall be properly anchored in place to resist wind loads. Additionally mc 1608.8 Roofprojections -Drift loads due to mechanical equipment, penthouses, parapets and other projections above the roof shall be determined in accordance with Section 7.8 of ASCE 7. HVAC permits will not be issued until screening plan is approved hy Planning Department \\SNAPMTSO:;\USERS\briann\2007 Comm Plan Rel'iew1i\X4- j 905-0207 550 S Rodier Sf Bldg Only.dt\(: Page 3 of 4 <. A copy of the approved planS, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. . In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the nmnber listed below or the address on this letterhead. Resp~ ~ Building Systems Consultant (920) 236-5051 Monday- Friday 7:30 A.M. t08:30 A.M and 12:30 A.M to 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 390.00 390.00 0.00 '..\SNAPI,l1S03\USERS\bri,lJm'2007 Comm Phm Reviews"X4-1905-0207 550 S Ko"Her 51 Dldg Only.do\: Page 4 of 4