HomeMy WebLinkAbout2007-HVAC (4 furnaces) . OSHKOSH ON THE WATER JobAddress 1333 WALNUT ST CITY OF OSHKOSH No 123426 HVAC PERMIT - APPLICATION AND RECORD Owner ST JOSEPHATS CONG Create Date 02105/2007 Plan X1-1880-0107 Contractor MARX MECHANICAL Fuel ~ Gas UOil System o New ~ Forced Air U Radiant U Electric U Hot Water Chimney Type () Chimney A C) Chimney B Heat Loss . As Approved () Existing BTU Rate . As Per Plan () Variable Category 510 -Ind. & Comm-Heating & Ventilating U Solar D Solid o Other U AlC 0 Vent U Con. Burner U Electric o Replace U Steam U Suppl. . Direct Vent () Not Applicable () Not Applicable Value () Other Value Use/Nature I nstall new' HV AC system - 4 furnaces and associated duct work as per plans 'Late Permit - work completed prior to plan approval or of Work permit issuance. $27,560.00 Plan Approval $0.00 Permit Fee Paid Fees: Valuation $646.00 Date 02/06/2007 Issued By: o Permit Voided I Parcelld # 1204660000 In the performance of this work, I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not.a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Agent/Owner Address 4535 STATE ROAD 91 OSHKOSH WI 54904 - 6304 Telephone Number 920-235-.6510 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (Le. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. City of Oshkosh Division oflnspection Services P,O. Box 1130 Oshkosh, WI 54903-1130 Phone (920) 236-5050 Fax (920) 236-5084 RE EIVED ~ , JAN 0 4 2007 OfHKOlO ON THf WAlfl/ HVAC PERMIT APpl.D~~MNT OF All infOJ111ation after bold catOOMMUN\ll~rDtMiLOPMENT Incomplete applications will not ?e processed. . Application(s) and fe'e(s) can be brought to City Hall, Room 205 or mailed to Inspection Services, PO Box 1128, Oshkosh WI 54903-1128. COlllmenclllg work without pennit(s) will result III fees being doubled or $100.00 plus the normal permit fee, which ever is greater. OR If vou are a contractor lJarticilJating in the Permit fee Account Svstem and have adequate funds. check here if ]IOU want thislJrocessed through vour account n DATE \ - 04-0'1 JOB ADDRESS \~3~ Wr-\LNLt\ s-r- OWNER ST JDSAfl-rf\T$ Fp&.J'0H \ ~LHnlJL- CONTRACTOR MARX MECHANICAL INC CHECK &::1 ALL APPLICABLE USE CATEGORY OSingle Family DDuplex o Multi-Family o Rental f5?1.Commercial o Illdustrial FUEL 1tJ Gas DOD OElectric .oSolid o Solar SYSTEM I29New DOther DReplace TYPE ltfForced All' ORadiant DSteam DAlC DVeut DElectric DHot Water DSuppL DCon. Burner IS CHIMNEY BEING LINED u9No DYes ~ LINER SIZE Note: All chimneys shall be sized per the BTU's being vented. & MANUFACTURER CHIMNEY TYPE HEAT LOSS BTU RATE o ChinUley A 1iQAs Approved ~As Per Plan DChllllney B DExisting DVariable a9Direct V~nt o Other DNot Applicable DOther Value DESCRIl"TlON OF ALL \VOH.K BEING DONE F1)O\Nb- L\ L0\lND~ RJiLNA-e!~ '\D lr\f SCtt()()L It) U~61-ADE" tsPfl C'__H?1,-lcy. w V A~UE (Including labor and ll1at~riaJs) $ 0(1)5 \00 . ELECTRlCAL CONTRACTOR ~\ 0 WN \?v2.S t?1xL.)rlLl0~1 A-N o For applicable projects, an Electric Installation Verification form, signed by the Electrical Contractor, must be attached. If not attached or not applicable, a separate Electrical Permit is required. 10/04 ~ OJHKOIH ON THE WATER City of Oshkosh Division of Inspection Services ;!15 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.cLoshkosh.wi.us February 5,2007 Paul Sobieck Temperature Systems Inc 2200 S Ashland Ave Green Bay WI 54307 The submittal described above has been reviewed for confoUnance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVE~. The owner, as defined in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) / Conditions: NOTE: Per documentation provided on 1/24/07 the Owner has stated t.hat the existing kitchen hood, kitchen hood fan and associated kitchen equipment will be removed. This plan approval is conditioned on the removal of that equipment, and the space previously used as a kitchen being used as a break room / office without any cooking equipment. . IBC 1101.2/ANSI A117.1-308.2 & 3 - Mechanical system controls shall be located a maximum of 48" above the finished floor if the floor space allows aforward approach by a wheel chair or if the clear space allows a parallel approach. . IMC 304.1 :Equipment and appliances shall be installed as required by the terms oftheir approval, in accordance with the conditions of the listing, the manufactures instructions and this code. . NEC 110.26 Spaces About Electrical Equipment. Sufficient access and working space shall be: provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. Verify that the appropriate clearances required by this section are being maintained - Caution with equipment being installed above drop ceilings . IMC 307.1 Liquid combustion by-products of condensing appliances shall be collected and discharged to an approved plumbing fixture or disposal area. Plans do not indiqate how condensate is being disposed - verify proper disposal. . IMC 401.5 Opening Location Outside air exhaust and intake openings shall be located a minimum of 10 feet (3048 mm) from lot lines or buildings on the same lot. Where openings front on a street or public way, the distance shall be measured to the centerline of the street or public way. \\OSH K()SH M lSFS\Dcpaltmcnts\Inspcdlnns\PlanRcvicw\<:ommcrdal Plan 2007\X 1-1 xilO-O ill: 1333 Sl Page 1 of2 · IMC 403.1 The amount of supply air shall be approximately equal to the amount ofretum and exhaust air. The plans do not show how the exhaust and MUA systems will be interlocked to comply with this requirement. Existing exhaustfans are required to run continuously when building is occupied - verify controls used for existing bathroom exhausts will provide for this. · IMC 403.2 Outdoor air required. The minimum ventilation rate of required outdoor air shall be determined in accordance with Section 403.3. Ventilation is required to be provided continuously while building is occupied. · IMC 403.3.4 Balancing Ventilation systems shall be balanced by an apptovedmeth6d. Such balancing shall verify that the ventilation system is. capable of supplying the airflow rates required by Section 403. · IMC 405.1 Mechanical ventilation systems shall be provided with manual or automatic controls that will operate such systems whenever the spaces are occupied. Air conditioning systems that supply required ventilation air shall be provided with controls designed to automatically maintain the required outdoor air supply rate during occupancy. · IECC Comm 63.1029(4) Additional duct sealing. (a) General. Except as specified in par. (b), ductwork and plenums shall be sealed in accordance with Table 63.1029-1, and shall meet the duct seal classes specified in Table 63.1029-2. Verify that ductwork in attic space is properly sealed - Pressure sensitive tape shall not be used as primary sealant. · Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm 61.31 (1). Plans submitted do not include Air Conditioning - additional plans will be required to be submitted and approved prior to installation of Air Conditioning System. SUBMIT: · IECC 503.3.3.7 [Comm 63.0503(2)(f)] Balancing and documentation of the HV AC system shall conform to the !MC. Balancing report required to be submitted prior to final occupancy being allowed. · Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. na e Building Systems Consultant (920) 236-5051 Monday - Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to I:30 P.M. bnoe@ci.oshkosh.wi.us Fee Required $ Fee Received $ Balance Due $ 320.00 0.00 320.00 cc: Property file \\()SH K()SHh,11SF'S\Dc;parttn(~nt.r.;\ITlspc{'tion~\PLm f~.e\'ie\v\(~crnmercia.j po);] n 2007\XT..J ! 333 Walnut Only.doc Page 2 of2