Loading...
HomeMy WebLinkAboutBuilding & HVAC W5-113-1106 ~ OJHKOfH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.cLoshkosh.wi.us ON THE WATER November 28, 2006 Patrick G Bless 219 North Second St Suite 301 Minneapolis, MN 55401-1454 Leland Franke Gries Architectural Group 500 North Commercial St Neenah, WI 54656 Andy Dumke Dumke Property 601 Oregon St. Suite A Oshkosh, WI 54901 Buffalo Wild Wings Corporate 1600 Utica Ave. Suite 700 Minneapolis, MN 55416 Site: Buffalo Wild Wings 500 S Koeller St Oshkosh WI 54902 For: Description: Tenant space alterations Object Type: Building and HV AC Class of Construction: lIB -5683 Sq Ft.; Occupancy: A2: Assembly MaXimum No of Occupants: 239 Plan Number: W5-113-1106 Sprinklered The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) I Conditions: . ICC/ANSI A1l7.1 404.2.4 Maneuvering Clearance at Doors. Minimum maneuvering clearances at door shall comply with Sections 404.2.4.1 through 404.2.4.7; It would appear that the door # 117 between the Bar storage area, and Bar area is being provided with a closer and would then require 12 inch minimum clearance on latch side of door projecting 48 inches in front of the door. It would appear that the audio / video equipment rack will infringe into this required space. Provide details as to how this issue will be resolved. . IBC 903.4 Sprinkler system monitoring and alarms. All valves controlling the water supply for automatic sprinkler systems and water-flow switches on all sprinkler systems shall be electrically supervised. . IRC 903.4.1 Signals. Alarm, supervisory and trouble signals shall be distinctly different and shan be automatically transmitted to an approved central station, remote supervising station or proprietary supervising station as defined in NFPA 72. NFPA 72 4.5.2 Provide a copy ofthefire alarm system record or completion for the required monitoring and alarms of the automatic fire sprinkler system . IRC 903.4.2 Alarms. Approved audible devices shall be connected to every automatic sprinkler system. Such sprinkler water-flow alarm devices shall be activated by water flow equivalent to the flow of a single sprinkler of the smallest orifice size installed in the system. Alarm devices shall be provided on the exterior ofthe building in an approved location. Where a fire alarm system is installed, actuation of the automatic sprinkler system shall actuate the building fire alarm svstem. H:'bri"",,,':'fHh (omm Pkin Review\W5-113-i 106 50\! S K(dw" Sf BUg & nv.'\c.t10(; Page 1 of4 · IRC 906.1 /IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet. Additionally a class K fire extinguisher is required to be located within 30 feet of commercial cooking equipment. · IBC 1003.2.2.5 Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit access doorway from the room or space. Posted signs shall meet the requirement of municipal code section 13-5. Min 12 inches in length, min 4 inches in height with min Yz inch lettering and the numbers being minimum 3 inches in height. The sign shall state "Limit (number) Persons". · IBC 1003.2~10 Exit signs are required to be installed per this section · . IBC 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress are required to have adequate emergency lighting to meet the performance requirements ofIBC 1003.2.11.3. Provide complete emergency lighting plan showing compliance with these requirements prior to installation of emergency lighting system. Current plans showing emergency lighting appear to be inadequate - additional emergency lights are required in the dinning area, and the patio area to comply with code required light levels. · IBC 2406.2 Glazing in an individual fixed or operable panel adjacent to a door where the nearest exposed edge of the glazing is within a 24 inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface is requires safety glazing materials. . IRC 2603 This .chapter governs the use of foam plastic insulation within buildings and structures. No construction details were provided for the walk in cooler. Verify that cooler construction will comply with the provisions of this chapter. · IMC 302.1 The building or structure shall not be weakened by the installation of mechanical systems. Verify that existing structure is capable of supporting the additional weight of the proposed roof top equipment. Original Building shell plans indicate maximum RTU weight of 1500#, while this plan set indicates 2800#, 2000#, and 1600# RTU loads. Provide structural calculations, and details on how roof joists will be reinforced for increased loads. . IMC 304.9 Guards. Guards shall be provided where appliances, equipment, fans or other components that require service are located within 10 feet (3048 mm) of a roof edge or open side of a walking surface and such edge or open side is located more than 30 inches (762 mm) above the floor, roof or grade below. The guard shall extend not less than 30 inches (762 mm) beyond each end of such appliance, equipment, fan or component and the top of the guard shall be located not less than 42 inches (1067 mm) above the elevated surface adjacent to the guard. The guard shall be constructed so as to prevent the passage of a 21-inch- diameter (533 mm) sphere and shall comply with the loading requirements for guards specified in the International Building Code. IT would appear that mechanical equipment is being located closer than 10 feet from the roofs edge, where parapet walls do not extend 42 inches high. Provide detailed information showing compliance with this section. . NEC 110.26 Spaces About Electrical Equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. Verify that the appropriate clearances required by this section are being maintained rt'll,,,,,.',,, :'iH\ \ "inm Phm Review\W5-113- ii()6 50!) [((,dler SiBldg &; nv!\c.do(; Page 2 of 4 · IMC 401.5.1 Mechanical and gravity outside air intake openings shall be located a minimum of 10 feet from any hazardous or noxious contaminant such as vents, chimneys, plumbing vents, streets, alleys, parking lots and loading docks. · IMC 401.3 [Comm 64.0401 (2)] When required. (a) Outside air. Mechanical ventilation systems shall be operated to provide a continuous source of outside air to all areas while people are present. (b )Operation. 1. Except as provided in subd. 2., the required building exhaust ventilating systems shall operate continuously when people are in the building to provide the amount of exhaust specified in Table 64.0403. Plans indicate that outside air is being controlled by C02 sensors. State of Wisconsin mechanical code requires that the minimum required outside air be continuously provided while people are present. Using a C02 sensor to reduce the amount of outside air below minimum levels is not permitted, and outside air is required to be provided anytime the space is occupied. · IMC 509.1 An approved automatic fire suppression system complying with the mc and !FC is required for this kitchen exhaust hood installation. · IBC 904.11.2 System Interconnection The Interconnection of the fire suppression system shall automatically shut down the fuel or electrical power supply to the cooking equipment. The fuel and electrical supply reset shall be manual. · IECC 503.3.3.7 [Comm 63.0503(2)(1)] Balancing and documentation of the HV AC system shall conform to the !MC. Balancing report required to be submitted prior to final occupancy being allowed. · IECC 803.3.3.3 Off-hour controls. Each zone shall be provided with thermostatic setback controls that are controlled by either an automatic time clock or programmable control system. · IMC 606.2.1 Smoke detectors shall be installed in return air systems with a design capacity greater than 2000 cfm...... · IMC 606.4.1 The duct smoke detectors shall be connected to a fire alarm system. The actuation of a smoke detector shall activate a visible and audible supervisory signal at a constantly attended location. · IMC 606.4.1 Exception 2. In occupancies not required to be equipped with a fire alarm system, actuation of a smoke detector shall activate a visible and an audible signal in an approved location. Smoke detector trouble conditions shall activate a visible or audible signal in an approved location and shall be identifies as air duct detector trouble. · Comm 5.34 No person may perform structural welding unless the person holds a registration issued by Department of Commerce. Provide welders registration numbers for all people doing welding on this project. · Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm 61.31(1). · Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. II:'J:rri(.Lnr('.2tHY~~. q:-~'~rn P1;.lr1 Ht~\'ie\\",,\V5-1 1 h)6 50(J S v.c>~.n~.~:' \~ fVdU. ct JTVAC.doG Page 3 of 4 4 · MUN 30 This review does not include review for signage. Applications for and questions regarding signage permits should be directed to David Buck - Associate Planner (920) 236-5062. · MUN 15 NOTE: Contact Sandy Knutson - Health Services (920) 236-5027 for additional information as to Health code requirements. Preliminary review indicates the need for an additional sink. · MUN 30-35 (1)(5) All rooftop and ground level mechanical equipment and utilities shall be fully screened from view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236- 5062 for additional information on screening requirements. All screening shall be properly anchpred in place to resist wind loads. Additionally IDe 1608.8 Roofprojections - Drift loads due to mechanical equipment, penthouses, parapets and other projections above the roof shall be determined in accordance with Section 7.8 of ASCE 7. Provide screening plan for all equipment that will be visible from a street or residential property. NOTE: No mechanical permits will be issued until a screening plan has been approved. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. R~ ~~ Building Systems Consultant (920) 236-5051 Monday-Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 800.00 800.00 0.00 n :\bri;Lm,'20U6 Phm Re\'ie\\'\\V5-1. 13-1 5('i1J :' K('>1~"i!~:. &; liY"\Cdo(; Page 4 of 4