Loading...
HomeMy WebLinkAboutFire Protection System Installation :/ J. F. AHERN CO. MECHANICAL & FIRE PROTECTION CONTRACTORS 201 Morris Court, P.O. Box 1316 Fond du Lac, WI 54936-1316 (920) 921-9020 P · (920) 921-8666 f www.jfahern.com November 13,2006 Building Inspector -- Brian Noe City of Oshkosh 215 Church Avenue -- PO Box 1130 Oshkosh, VVI 54901 T -920/236-5051 F-9201236-1130 RE: FIRE PROTECTION SYSTEM INSTALLATION HUNTERS RIDGE 3100 ELK RIDGE DRIVE, BUILDING 16 OSHKOSH, WISCONSIN 54901 AHERN FIRE PROTECTION PROJECT No. 993881 Dear Brian: Enclosed is a copy of the Contractor's Material and Test Certificates covering the above-referenced Fire Protection System Installation for your files. Very truly yours, AHERN FIRE PROTECTION A division of J. F. Ahem Co. M~(t/&!f Service Superintendent MLJ/ksj R"E~ iii',. EI LCITYII-13-06.DOC NOV 1 4 2006 DEPARTMENT OF COMf\lWNITY DEVELOPMENT Building the Midwest Since 1880 An Equal Opportunity Employer AHERN FIRE PROTECTION Contractor's Material and Test Certificate for Aboveground Piping PROCEDURE Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor, It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. PROPERTY NAME Hunters Ridge AFP W.O. #: 993881 I DATE: October 12, 2006 PROPERTY ADDRESS Building 16 - 3100 Elk Ridge Drive Oshkosh, WI 54901 ACCEPTED BY APPROVING AUTHORITIES (NAMES) 1. Oshkosh Fire Department (Battalion Chief -- Stu Schrottky) 2. City of Oshkosh (Building Inspector -- Brian Noe) 3. 4. ADDRESS Plans 1. 101 Court Street -- Oshkosh, WI 54901 2. 215 Church Avenue -- PO Box 1130 -- Oshkosh, WI 54901 3. 4. INSTALLATION CONFORMS TO ACCEPTED PLANS ~YES DNO EQUIPMENT USED IS APPROVED YES DNO IF NO, EXPLAIN DEVIATIONS HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION III YES DNO OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? INSTRUCTIONS IF NO, EXPLAIN HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES: B Item No.'s 2 & 3 will 1. SYSTEM COMPONENTS INSTRUCTION YES DNO be forwarded by AFP 2. CARE AND MAINTENANCE INSTRUCTIONS ...YES DNO at closeout time. 3. NFPA 25 YES DNO LOCATION OF SUPPLIES BUILDINGS SYSTEM BuildinQ 16 MAKE MODEL YEAR OF K- QUANTITY TEMPERATURE MANUFACTURE FACTOR RATING Central LFII TY2234 Pendent 1/2" White 2006 4.9 47 155 Deg. SPRINKLERS . PIPE AND TYPE OF PIPE Liqhtwall Non-Threadable; Thinwall Threadable: Black FITTINGS TYPE OF FITTINGS Grooved; Threaded; Mechanical Tees FLOW ALARM DEVICE MAXIMUM TIME TO OPERATE THROUGH TEST CONNECTION TYPE MAKE MODEL MIN. SEC. Water Flow Detector System Sensor WFD - ~ N/A EXPLAIN ANY ALARM PROBLEMS: ALARM DEVICES LOW AIR ALARM DEVICE rfif'~Ir: ALARM OPERATED TYPE I MAKE MODE~ If'-=" =[)ROPERL Y N/A KF'! S I NO '" ",,,,,,"- ~~~" W I!k= I EXPLAIN ANY ALARM PROBLEMS: NOV 1 4 2006 !"'or""']' ""....m ~f"B~.... ...."'" '-'!..i .,..! ~'I!..,'i, VB COMMUNITY DEVELOPMENT CENTRAL MONITORING SIGNALS RECEIVED ALARM SERVICE LOCATION(S) TYPE OR PRESSURE NAME OF REMOTE WATERFLOW SWITCH LOW-AIR OTHER SERVICE DETECTOR FLOW SUPERVISORY ;J/II- SUPERVISING LOCATION(S): STATION (ON-SITE) REMOTE REMOTE NAME OF SERVICE: MONITORING ALARM SERVICE SIGNALING (OFF-SITE) PHONE: OTHER: LOCATION(S): , EXPLAIN ANY ALARM SIGNALING PROBLEMS: ; DRY VALVE Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO, /fir TIME WATER ALARM TIME TO TRIP WATER TRIP POINT AIR THROUGH TEST PRESSURE AIR PRESSURE PRESSURE REACHED TEST OPERATED CONNECTION,.2 OUTLET '.2 PRO PERL Y DRY PIPE , MIN. SEC. PSI PSI PSI MIN. SEC. YES NO OPERATING WITHOUT TEST 0.0,0. , WITH 0.0.0. IF NO, EXPLAIN: OPERATION: o PNEUMATIC 0 ELECTRIC D HYDRAULIC .;f/ 1ft PIPING SUPERVISED DYES DNO DETECTING MEDIA SUPERVISED DYES 'DNO ," DOES VALVE OPERATE FROM THE MANUAL TRIP, REMOTE, OR BOTH CONTROL STATIONS DYES DNO IS THERE AN ACCESSIBLE FACILITY IN EACH IF NO, EXPLAIN DELUGE & CIRCUIT FOR TESTING PREACTION DYES DNO VALVES DOES EACH CIRCUIT " DOES EACH CIRCUIT MAXIMUM TIME TO OPERATE SUPERVISION OPERATE VALVE RELEASE OPERATE RELEASE MAKE MODEL LOSS ALARM YES NO YES NO MIN. SEC. ~'tRE LOCATION & MAKE & MODEL SETTING STATIC PRESSURE RESIDUAL PRESSURE FLOW RATE FLOOR (FLOWING) INLET OUTLET INLET OUTLET FLOW REDUCING (PSI) (PSI) (PSI) (PSI) , (GPM) VALVE TEST Ahern Fire Protection 1 MEASURED FROM TIME INSPECTORS TEST CONNECTION is OPENED. 2 NFPA 13 ONLY REOUIRES THE 60-SECOND LIMITATION IN SPECiFiC SECTIONS, 2 TEST DESCRIPTION TESTS BLANK TESTING GASKETS WELDING CUTOUTS (DISCS) HYDRAULIC DATA NAMEPLATE REMARKS SIGNATURES Ahern Fire Protection HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bars) for two hours or 50 psi (3.4 bars) above static pressure in excess of 150 psi (10.2 bars) for two hours, Differential dry-pipe valve clappers shall be left open during test to prevent damage. All aboveground piping leakage shall be stopped. PNEUMATIC: Establish 40-psi (2.7 bars) air pressure and measure drop, which shall not exceed 1-1/2 psi (0,1 bars) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. ALL PIPING HYDROSTATICALLY TESTED AT ..,)~ PSI <-Bar) for ~ HRS. IF NO, STATE REASON DRY PIPING PNEUMATICALLY TESTED 0 YES D NO EQUIPMENT OPERATES PROPERLY ~ YES D NO DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM SILICATE OR DERIVATIVES OR SODIUM SILICATE, BRINE, OR OTHER CORROSIVE CHEMICALS WERE NOT USED FOR TESTING SYSTEMS OR STOPPING LEAKS? YES 0 NO DRAIN READING OF GAUGE LOCATED NEAR WATER RESIDUAL PRESSURE WITH VALVE IN TEST TEST SUPPLY TEST CONNECTION:.6.B- PSI ( Bar) CONNECTION OPEN WIDE: 1a PSI LBar) UNDERGROUND MAINS AND LEAD IN CONNECTIONS TO SYSTEM RISER OTHER EXPLAIN FLUSHED BEFORE CONNECTION MADE TO SPRINKLER PIPING. DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES .cOMPLY WITH THE REQUIREMENTS OF AT LEAST AWS B2.1? DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS 0 YES QUALIFIED IN COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS B2.1? VERIFIED BY COpy OF THE CONTRACTOR'S MATERIAL AND TEST CERTIFICATE FOR UNDERGROUND PIPING. 0 YES 0 NO FLUSHED BY INSTALLER OF UNDERGROUND SPRINKLER PIPING 0 YES 0 NO IF POWDER-DRIVEN FASTENERS ARE USED IN CONCRETE, HAS REPRESENTATIVE SAMPLE TESTING BEEN SATISFACTORILY COMPLETED? . . D~D~ NUMBER USED aVl~ WELDED PIPING IF YES... LOCATIONS NO DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO ENSURE THAT ALL DISCS ARE RETRIEVED, THAT OPENINGS IN PIPING ARE SMOOTH, THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL CUTOUTS (DISCS) ARE RETRIEVED? NAME PLATE PROVIDED ,!2t' YES 0 NO DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: 10- 30-0 f.c NAME OF SPRINKLER CONTRACTOR AHERN FIRE PROTECTION, 201 MORRIS COURT -- FOND DU LAC, WI 54935 TESTS WITNESSED BY AU1r:~~:l~: JURISDI TION (SIG_NED) "TITLE FOR PROPERTY OWNER (SIGN' D) TITLi '.,k p~ 3 ~'( ().fL.~.4;. IF NO, EXPLAIN V<::,v1' NUMBER REMOVED DYES DNO DNO DYES DNO 12!YES DNO IF NO, EXPLAIN DATE /0 - J, fJ . 0--6 DATE DATE 1O--?O ...0(0