HomeMy WebLinkAboutCertificate of Occupancy CITY HALL Inspection Services Div 215 Church Avenue PO Box 1130 ~ Osh""'" WI ~ 54903-1130 OJHKOJH ON THE WATER . City of Oshkosh Approved: Issued: January 25, 2007 January 29, 2007 David & Joan Ritmanich 14755 Jewel Dr. Brookfield, WI 53005-7022 CERTIFICATE OF OCCUPANCY An Occupancy Permit is hereby granted for the new single family residence located at 3072 Lake Rest Lane, Oshkosh, Wisconsin 54902 as described in Building Permit Application number(s) 121342. This building is to be used only as a single family residence and is located in the R-1 LO, Single Family Residence District, Lakeshore Overlay. LIMITATIONS: Maximum persons and/or living units: One living unit CONDITIONS: 1) Final grading must be done in accordance with the approved subdivision drainage plan. This plan is on file in the public works office, 3ra floor of City Hall. 2) Erosion control measures must be maintained until the lawn is established. Note: Final grade must be a minimum of 6" below all siding. NOTE: 1) Copies of inspection results are available upon request in room 205, City Hall. 2) Future permits may be required for additional work to your property. A new Certificate of Occupancy shall be required prior to occupancy, should additional building(s) be erected, or should any buildings mentioned above be altered or moved. The use of land, or buildings, shall not be changed until a Certificate of Occupancy is issued for that occupancy. All conditions noted above must be complied with in order for this certificate to be valid. ~ems Inspector Cc: Portside Builders, Inc. Job Address 3072 LAKE REST LN Building Permit Work Card Permit Number 0121342 Create Date 8/24/2006 Owner DAVID C & JOAN M RITMANICH Category 110 - New Single Family Contractor PORTSIDE BUILDERS, INC. Plan 040-0806 Occupany Permit Required Flood Plain No Height Permit Not Required Class of const: Use/Nature NSFR/ 2 story home with a 2 car attached garage, deck, and driveway. of Work 8 -, I I --' HVAC Contr MCM AIR INC Electric Contr SCHOMMER ELECTRICAL CONTRACTU Plumbing Contr SBS PLUMBING LLC Inspections: Date 12/5/2006 Type Reinspect Inspector Nicole Krahn equest Line / Ready for a re-inspection, Tuesday aftemoon 12-5-06 approved i I -.I Date/Timerequested: 12/4/2006 03:04 PM Notice Type: FC -_.__._~,-----,.~------.- Access: I ____________ nnnn____ Requested By: PORTSIDE BUILDERS, INC. - Bob o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid Ready Date/Time: 12/5/2006 00:00 PM _________1 I Phone Number: Date 1/24/2007 Type Final _____ Inspector John Zarate not approved Request IinePost address, rise off of front stoop, joints in fjreseperation wall (garage), egress window 2nd floor bedroom (lake side), seal i nds of ENT from crawlspace. I I Date/Time requested: 1/23/2007 01:54 PM Notice Type: FC Ready Date/Time: 1/23/2007 01:54 PM Access: IEntry code #41025 Requested By: PORTSIDE BUILDERS, INC. - Bo~ Phone Number: 727-4874 o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid _J Date 1/25/2007 Type Re Final __________ Inspector John Zarate REQUEST LINE / READY FOR ARE-INSPECTION approved I I I i ; i _J Date/Time requested: 1/25/2007 11 :56 AM Notice Type: Access: !LOCK BOX CODE #41025 Requested By: PORTSIDE BUILDERS, INC. - BOB o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid Ready DatelTime: 1/25/2007 11 :56 AM Phone Number: Page 2 of 2 Building Permit Work Card Job Address 3072 LAKE REST LN Permit Number 0121342 Create Date 8/24/2006 Owner DAVID C & JOAN M RITMANICH Contractor PORTSIDE BUILDERS, INC. Category 110 - New Single Family Plan 040-0806 Occupany Permit Required Flood Plain No Height Permit Not Required Class of Const: 8 Use/Nature ~SFR/ 2 story home with a 2 car attached garage, deck, and driveway. of Work HVAC Contr MCM AIR INC Plumbing Contr SBS PLUMBING LLC Electric Contr SCHOMMER ELECTRICAL CONTRACTU Inspections: Date 10/5/2006 Type Footings Inspector Adam Krause Request Line 1 Ready for a footing/foundation inspection*Nikki, forms already set. Couldn't verify footing depth due to water. approved Date/Time requested: 10/5/2006 07:26 AM Access: Requested By: PORTSIDE BUILDERS, INC. - John Evans o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid Notice Type: Ready DatelTime: 10/5/2006 07:26 AM Phone Number: (920) 727~4874 Date 10/16/2006 Type Foundation Backfill Hequest Line / Ready for a foundation inspection Inspector Nicole Krahn approved DatelTime requested: 10/13/2006 11 :41 PM Notice Type: Access: I Requested By: PORTSIDE BUILDERS, INC. - John Evans o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid Ready DatelTime: 10/13/2006 11 :41 AM Phone Number: (910) 727-~874 Date 10/23/2006 10:00 AM Type Drain Tile Request line/Would like to pour 7:00 am 10/24 Inspector Adam Krause approved Date/Time requested: 10/23/2006 08:09 AM Notice Type: Access: C ----- Requested By: Bastion Construction - Terri __ o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid Ready Date/Time: 10/23/2006 08:09 AM -1 Phone Number: 920-836-3009 Date ~~~~~_ Type Insulation Inspector Nicole Krahn not approved Request Line / Ready for an insulation 12-01-06 in the mid morning No rough inspection was conducted prior to insulating the house. conducted the rough inspection with the insulation inspection and noted the violations that could be seen. DatelTime requested: 11/30/2006 08:50 AM Notice Type: FC Access: [=~___ Requested By: -,=-OX VALLEY INSULATION - TODD o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid Ready DatelTime: 12/1/2006 00:00 AM Phone Number: (920) 428-0055 Page 1 of 2 Electric Permit Work Card Job Address 3072 LAKE REST LN Permit Number 122342 Create Date 8/31/2006 Owner DAVID C & JOAN M RITMANICH Contractor. SCHOMMER ELECTRICAL CONTRACTlt Service Ie New o ChangeO Temp o N/A I Type 0 Overhead . Underground o N/A I Volts 120/240 Circuits Luminaires Amps 200 Switches Receptacles Value $4,675.00 Use/Nature 611 - Residential-New Single Family Wiring NSFR/ WIRE A NEW HOME WITH 200AMP UG SERVICE of Work Inspections: Date 10/31/2006 Type Service Inspector Adam Krause Faxed Request / Ready for a service inspection NOW Faxed approval to WPS 11-01-067:45 AM approved DatelTime requested: 10/31/2006 12:58 PM Access: Requested by: SEC INC - Bob Schommer Phone Number: (920) 731-2299 o Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid - -- - - - - - ----- - - - - -- - - --- - -- - - --- -- - - - - -- - - --- - -- - - - - - - - -- -- -- -- - - - -- -- - - -- - -- - - - - ---- - - - - - - - - - ---- -- - - - - - - -- - - --.. - - ------ - - ---- - -- -- -- - ------ - -- -- - -- - - - - - -- Date 11/27/2006 Type Roughln Inspector Adam Krause approved Notice Type: Ready DatelTime: 10/31/200601:00 PM rax rno,esl DatelTime requested: 11/22/2006 09:00 AM Access: Notice Type: Ready OatelTime: 11/27/2006: PM Requested by: SCHOMMER ELECTRICAL CONTRACTIN O. Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid Phone Number: Bob - 920-731-2299 Date 01/24/2007 Type Final Inspector Adam Krause approved 1-24. Check GFCls at kitchen. Exterior lighting and power. Data ENTs in crawlspace. 14-2s supported in crawlspace. Not requested. Getting inpsection done to save time.JOhn Z averifed things were complete that were not done yesterday. l J DatelTime requested: 01/24/2007 08:26 AM Access: Notice Type: Ready DatelTime: 01/24/2007 08:26 AM Requested by: SCHOMMER ELECTRICAL CONTRACTIN o Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid Phone Number: Job Address 3072 LAKE REST LN HVAC Permit Work Card Permit Number 120858 Create Date 08/01/2006 Owner DAVID C & JOAN M RITMANICH Contractor MCM AIR INC Fuel ~ Gas I O--Oill l I Electric I U Solar U Solid I Value ________E,?OO.OO System aNew I 0 Replace I 0 Other I ~ Forced Air J U Radiant I U Steam I ~ AlC I U Ven~~ U Electric ] U Hot Water I U Sup pI. I U Con. Burner I Chimney Type (I:gI~imney A 0 Chimney B . Direct Vent 0 Not Applicabte~=:J Use/Nature NSFR / INSTALL NEW 60,000 BTU FURNACE AND DUCTWORK AND 2.5-TON AlC SYSTEM of Work . Inspections: Date 12/4/2006 Type Rough In Fax request Inspector Nicole Krahn approved Date/Time requested: 11/27/2006 11 :21 AM Access: I Requested By: MCM AIR INC o Reinspect Fee 0 Fee Waived Notice Type: Ready Date/Time: 11/27/2006 11:21 AM Phone Number: 582-4402 o Reinspect Fee Paid Date 1/24/2007 Type Final Inspector John Zarate approved c-~ DatelTime requested: 01/24/2007 10:46 AM Access: I Requested By: _______ o Reinspect Fee 0 Fee Waived Notice Type: Ready DatelTime: 01/24/2007 10:46 AM Phone Number: o Reinspect Fee Paid Inspections for Work Card 87764 Date 10/19/2006 Type Underground Inspector Paul Wolf ~'!ll not approved lSanitary sewer has been cut-off in dewater the basement. Area de-watered is 37'x32'x6", which is 4428 gallons/ 592 cu feet of water. Spoke with Derek from IsBs, he admitted that he cut-off the sewer to dewater.Citation request was sent to Allyn on 10/20 by Paul. DatelTime requested: 10/20/200107:14 AM Notice Type: Telephone Number: Access: I Ready DatelTime: 10/20/200107:14 AM Requested By: SBS PLUMBING LLC o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid Date 10/20/2006 Type Underground Inspector Paul Wolf approved Kitchen stack vents FD through comb. drain and vent. DatelTime requested: 10/20/200m8:26 AM Notice Type: Telephone Number: Access: I Ready DatelTime: 10/20/200108:26 AM Requested By: SBS PLUMBING LLC o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid Date 11/21/2006 Type Rough In Inspector Paul Wolf approved 1stand 2nd floors. OatelTime requested: 11/20/200104:02 PM Access: I Ready DatelTime: 11/20/2001 04:02 Pr-.-l_ Requested By: SBS PLUMBING LLC - Landon o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid Notice Type: Telephone Number: 427-9580 Type Final Inspector John Zarate approved Date 1/24/2007 Request line DatelTime requested: 1/23/200703:52 PM Notice Type: Telephone Number: Access: iOpen during normal business .~~~iS=~. Ready Date/Time: 1/23/2007 03:53_~rv1_. Requested By: SBS PLUMBING LLC - Dan o Reinspect Fee 0 Fee Waived 0 Reinspect Fee Paid - Plumbing Permit Work Card Job Address 3072 LAKE REST LN Permit Number 120869 Create Date 08/01/2006 --- Owner DAVID C & JOAN M RITMANICH Contractor SBS PLUMBING LLC Category 410 - Residential-Interior Plan Value $6,840.00 Bathtub 2 Shower -- Water Softner Wait. St. Shamp Sink - Coffee Maker - - - - Whirlpool Floor Drain 2 Local Waste Ice Chest FlrlWst Sink Int Grease Trap - - - - - Lavatory 2 Lndry Tray 1 Clothes Wshr 1 Exam Sink Catch Basin Ext Grease Trap - - - - - Toilet 2 Disposal Bidet Sculry Sink Wash Ftn RPZ Valve - - - - - Res. Sink 1 Dishwasher 1 Beer Tap Hand Sink Urinal Eye Wash Statn - - - - - Bar Sink Sump Pump 1 Lab Sink Plaster Sink Standp Rec 2 Wtr Sewer Mtrs - -- - - - - Water Heater 1 Classrm Sink Sterilizer Surgeons Sink Ice Maker Deduct Meters - -- - - - - Site Drain - Breakrm Sink -- Dip Well - F Prep Sink - Gar Drain - Wtr Usage Mtrs - Roof Drain - Ejector/Grind - Drink Ftn - Serv Sink - Soda Disp - Misc. 2 OUTSIDE SILCOCKS - Fixtures Use/Nature NSFR/ INTERIOR PLUMBING, POWER VENT WATER HEATER. **DEBIT ACCT of Work , , ! Size Material Type # Conn. Type Sanitary Sewer Storm Sewer Water Service