HomeMy WebLinkAboutBuilding - Revisions " ~ OJHKOJH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.cLoshkosh.wi.us ON THE WATER September 28, 2006 Lewis Bauer Cadre Inc 131 S Main St Fond du Lac WI 54935 Howard Floeter Cadre Inc 131 S Main 8t Fond du Lac WI 54935 Dan Dowling PO BOX 3045 Oshkosh WI 54903 Site: Plan Number: Q5-85-0905-R2 3596 Sterns Dr Oshkosh WI 54901 For: Description: Sunset School Conversion Object Type: Building only - Revisions to 9/27/05 approval, and Subsequent Revision 12/9/05 Building Type: VB - 5843 Sq. Ft. Vnsprinklered Occupancy: B: Business SI, S2, :Storage The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Hem(s) / Conditions: · Comm 62.706.4 Continuity All fire barriers shall extend from the top of the floor / ceiling below to the underside of the floor or roof slab / deck above and be securely attached thereto. This barrier shall be continuous and supporting construction shall be protected to afford the required fire resistance rating of the fire barrier. Please note the affect of the 2 hour fire barrier over the mechanical room must maintain this rating. · Comm 62.719 The designer shall provide analysis and verification that the existing construction for the fire barriers and fire walls satisfy the required fire rating. Walls previously identified as being fire barriers are now required to meet the requirements of a fire wall due to change in occupancy classification. · 2304.9.5 Fasteners in preservative-treated and fire-retardant-treated wood. Fasteners for preservative-treated and fire-retardant-tre~ted wood shall be of hot-dipped zinc coated galvanized steel, stainless steel, silicon bronze or copper. Fastenings for wood foundations shaIl be as required in AF&P A Technical Report No.7. · Comm 61.30(3) /IMC 507.2 This plan review does not include heating, ventilation, or air conditioning. HV AC plans are required to be submitted and approved prior to installation ofHV AC equipment. Owner is reminded that no plans for HVAC have been submitted to date for the phase II portion of this project. Ii:\bri"mn\2()(}(i Comm Plan Review\Q5-85"()905-IU 3596 Skms .Dr THug Only.doc Page I of2 A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. _R~ ~~ Building Systems Consultant (920) 236-5045 Monday - Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1 :30 P.M. adannhoff@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 150.00 150.00 0.00 ]! '.briann'.200(i Comrn Plan Re1.'ie\V\Q5-85-0905-R2 3596 Skms .Dr T.lidg Only.dot Page 2 of2