Per your request a final bui lding inspection was made at 2515
Gaslight Court on December 20, 1993. The following items were found
to be in noncompliance:
1) Per ILHR 21.08, fire separation must be maintained at the
intercom location in the garage firewall.
2) Per ILHR 21.04, maximum step to grade from front stoop shall not
exceed 8 inches.
3) Per ILHR 21.04, install temporary steps out rear doors or secure
the doors until the deck is installed.
4) Per ILHR 21.22, secure the posts to the I-Beams in the basement.
5) Per ILHR 21.07, install attic scuttle hole cover on first floor.
6) Per ILHR 21.29(12), install chimney cap on fireplace chimney.
All above items must be corrected, and final inspection called for
within 30 days of this notice in order to secure the certificate of
occupancy. Please call 236-5051 if you have any further questions
in this matter.