HomeMy WebLinkAbout12/28/94-Building Violations ~ 'l\L~ cc?~ CITY OF OSHKOSH, CODE ENFORCEMENT DIVISION 215 CHURCH AVENUE, OSHKOSH, WISCONSIN 54901 ~ OJH<OfH ON THE WATER page 1 CORRECTION NOTICE DATE INSPECTED 12/28/1994 OCCUPANCY INSPECTED New Sin Ie Famil Residence ADDRESS 1530 Galwa Court OWNERS NAME AND ADDRESS Kevin Jahnke 2680 Templeton Pl. Oshkosh. WI 54904 NOTICE DELIVERED/EXPLAINED TO: Kevin Jahnke 1530 Galwav Court Oshkosh. WI 54904 ITEM # ORDER 1.) 21.17 2. ) 21.04 3. ) 21.04 4.) 22.06 5. ) 22.08 6. ) 21.09 7. ) 21.22 FINDINGS OF INSPECTION Install a suitable cover on the sump pit. Handrail height shall be located between 30 and 34 inches above the nosing of the treads. Install handrails at both stairways. All stairways must have uniform riser height and tread depth. No riser may exceed 8 inches in height. Uniformity shall be to within 3/16 of an inch. Top step on interior stairway Install firecode drywall cover on attic scuttle opening in garage ceiling. Install smoke detectors, one on each floor level. These detectors shall be continuously powered by the house electrical service, and shall be interconnected. Nail all cross bridging. Deficiencies must be corrected and approved before concealment. Call 236-5051 to arrange for a final inspection. COMPLIANCE DATE: Jan 31.1995 INSPECTOR: Ken Staehler ~.~ t "-~" CITY OF OSHKOSH, CODE ENFORCEMENT DIVISION 215 CHURCH AVENUE, OSHKOSH, WISCONSIN 54901 page 1 ~ OJHKOJH ON THE WATER CORRECTION NOTICE DATE INSPECTED 12/28/1994 OCCUPANCY INSPECTED New Sin Ie Famil Residence ADDRESS 1530 Galwa Court OWNERS NAME AND ADDRESS Kevin Jahnke 2680 Templeton Pl. Oshkosh, WI 54904 NOTICE DELIVERED/EXPLAINED TO: Kevin Jahnke 1530 Galwav Court Oshkosh, WI 54904 ITEM # ORDER FINDINGS OF INSPECTION 1.) 2. ) 21.17~nstall a suita~le cover on the sump pit. ./' 21. 04 Handrail height shall be located between 30 and 34 inches above the nosing of the treads. Install handrails at both stairways. 3 . ) All stairways must have uniform riser height and tread depth. No riser may exceed 8 inches in height. Uniformity shall be to within 3/16 of an inch. Top step on interior stairway does not comply. 4. ) 5. ) 22.06 Install all boxsill insulation in basement. 22.08 Install firecode drywall cover on attic scuttle opening in garage ceiling. 6. ) 21.09 7. ) Ins 11 smoke detectors, one on each floor evel. These detectors shall be continuously powered by the house electrical service, and shall be interconnected. 21. 22 cross bridging. Deficiencies must be corrected and approved before concealment. Call 236-5051 to arrange for a final inspection. /<7 --;;/6!?S -?' /1eA15 I) 31 (;:. f- Lx;;^1€. ~. . fl) /CEMAlr\)fN6 rT"GUS . SliLL UoAIt>I.5I-<d>. .J4!{f--J/C{; CA...(... ~G: rJ{15 f-<.)~.- COMPLIANCE DATE: Jan 31,1995 INSPECTOR: Ken Staehler ~s ,@ .j@..0.J..110