January 10, 2007
Stephen Gries
Gries ArchitecturalGroup Inc.
500 N Commercial Street
Neenah, WI 54956
Andy Dumke
River Valley One LLC
601 Oregon St Suite A
Oshkosh, WI 54902
Site: Plan Number: XI-1878-0107
Verizon Wireless
/550 S Koeller St
Oshkosh WI 54904
For:
Description: Tenant space Build Out
Object Type: Building only
Class of Construction: VB - 3009 Sq Ft.; sprinklered
Occupancy: B: Business Office
Maximum No of Occupants: 96'
The submittal described above has been reviewed for conformance with applicable Wisconsin Administtative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Hem(s) / Conditions:
· IBC 901.2 Fire protection systems shall be installed, repaired, operated and maintained in accordance with this code
and the international fIre code. Construction of new walls may require the addition and or relocation of sprinkler
heads to maintain required coverage, and not obstruct spray patterns of fire sprinklers.
· mc 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress through
The Retail Display area are required to have adequate emergency lighting to meet the performance requirements of
IBC 1003.2.11.3. Provide complete emergency lighting plan showing compliance with these requirements prior
to installation of emergency lighting system. The emergency lighting shown on the plan does not appear adequate
to meet required light levels. '
· IBC 1004.3.2;1 Construction Corridors shall be fIre-resistance rated in accordance with Table 1004.3.2.1. The
corridor walls required to be frre-resistance-rated shall comply with Section 708 for frre partitions.
Table 1004.3.2.1 Exception c. Buildings equipped throughout with an automatic sprinkler system in
accordance with Section 903.3.1.1 or 903.3.1.2. This will require the monitoring and alarms per Section 903.4
this inciudes ALL valves controllinf! water supplv.
· mc 1209.1 Provide toilet room floors with smooth, hard, nonabsorbent surface extending minimum 6 inches up
onto walls.
l:\insp'~()t.ion.<:j\Plan Revic\lV'\Conunctdai Plan Rcv;~~"\v 2007\Xl..1S7S-010755p"S KocHer
Only.do,;
Page I of2
· Comm 61.30(3) / IMC 507.2 This plan review does not include heating, ventilation, or air conditioning.
HV AC plans are required to be' submitted and approved prior to installation of HV AC equipment. Be aware that
IBC 1004.3.2.4 contains additional restriction for air movement in corridors
· Comm 80 This plan review does not include plumbing. Prior to installation of plumbing, plans and calculations
are required to be submitted and approved. Contact Plumbing Inspector Paul Wolf (920) 236-5052 for additional
information.
· MUN 30 This review does not include review for sign age. Applications for and questions regarding signage
permits should be directed to Todd Muehrer, - Associate Planner (920) 236-5057
· Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under
this code and which are made to construction documents that have previously been granted approval by the
department or its authorized representative, shall be submitted to the offIce that granted the approval. All revisions
and modifications to plans shall be approved in writing by the department or its authorized representative prior to the
work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or
specification shall be signed and sealed in accordance with Comm 61.31 (1).
SUBMIT:
· mc 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress through
The Retail Display area are required to have adequate emergency lighting to meet the performance requirements of
mc 1003.2.11.3. Provide complete emergency lighting plan showing compliance with these requirements prior
to installation of emergency lighting system.
· Comm 61.30(3) This review does not include lighting. Comm 63.0001 Prior to installation, lighting plans and
calculations shall be prepared in compliance with the code. Please submit lighting work sheets.
· Com 61.50 (4) Supervision. Prior to the iriitial occupancy of an alteration the supervising professional shall file a
compliance statement form SBD-9720 with this office.
· . NFP A 72 4.5.2 Provide a copy of the frre alarm system record or completion for the required monitoring and alarms
of the automatic fire sprinkler system
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, br component.
Inquiries concerning this correspondence may be made to me at the numberlisted below or the address on this letterhead.
Re.s~~
~
Building Systems Consultant
(920) 236-5051 Monday-Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
Fee Required
Fee Received
Balance Due
$
$
$
390.00