Loading...
HomeMy WebLinkAboutBuilding Plan X1-1878-1007 ~ OJHKOfH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.ci.oshkosh.wi.us ON THE WATER January 10, 2007 Stephen Gries Gries ArchitecturalGroup Inc. 500 N Commercial Street Neenah, WI 54956 Andy Dumke River Valley One LLC 601 Oregon St Suite A Oshkosh, WI 54902 Site: Plan Number: XI-1878-0107 Verizon Wireless /550 S Koeller St Oshkosh WI 54904 For: Description: Tenant space Build Out Object Type: Building only Class of Construction: VB - 3009 Sq Ft.; sprinklered Occupancy: B: Business Office Maximum No of Occupants: 96' The submittal described above has been reviewed for conformance with applicable Wisconsin Administtative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Hem(s) / Conditions: · IBC 901.2 Fire protection systems shall be installed, repaired, operated and maintained in accordance with this code and the international fIre code. Construction of new walls may require the addition and or relocation of sprinkler heads to maintain required coverage, and not obstruct spray patterns of fire sprinklers. · mc 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress through The Retail Display area are required to have adequate emergency lighting to meet the performance requirements of IBC 1003.2.11.3. Provide complete emergency lighting plan showing compliance with these requirements prior to installation of emergency lighting system. The emergency lighting shown on the plan does not appear adequate to meet required light levels. ' · IBC 1004.3.2;1 Construction Corridors shall be fIre-resistance rated in accordance with Table 1004.3.2.1. The corridor walls required to be frre-resistance-rated shall comply with Section 708 for frre partitions. Table 1004.3.2.1 Exception c. Buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2. This will require the monitoring and alarms per Section 903.4 this inciudes ALL valves controllinf! water supplv. · mc 1209.1 Provide toilet room floors with smooth, hard, nonabsorbent surface extending minimum 6 inches up onto walls. l:\insp'~()t.ion.<:j\Plan Revic\lV'\Conunctdai Plan Rcv;~~"\v 2007\Xl..1S7S-010755p"S KocHer Only.do,; Page I of2 · Comm 61.30(3) / IMC 507.2 This plan review does not include heating, ventilation, or air conditioning. HV AC plans are required to be' submitted and approved prior to installation of HV AC equipment. Be aware that IBC 1004.3.2.4 contains additional restriction for air movement in corridors · Comm 80 This plan review does not include plumbing. Prior to installation of plumbing, plans and calculations are required to be submitted and approved. Contact Plumbing Inspector Paul Wolf (920) 236-5052 for additional information. · MUN 30 This review does not include review for sign age. Applications for and questions regarding signage permits should be directed to Todd Muehrer, - Associate Planner (920) 236-5057 · Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the offIce that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm 61.31 (1). SUBMIT: · mc 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress through The Retail Display area are required to have adequate emergency lighting to meet the performance requirements of mc 1003.2.11.3. Provide complete emergency lighting plan showing compliance with these requirements prior to installation of emergency lighting system. · Comm 61.30(3) This review does not include lighting. Comm 63.0001 Prior to installation, lighting plans and calculations shall be prepared in compliance with the code. Please submit lighting work sheets. · Com 61.50 (4) Supervision. Prior to the iriitial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. · . NFP A 72 4.5.2 Provide a copy of the frre alarm system record or completion for the required monitoring and alarms of the automatic fire sprinkler system A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, br component. Inquiries concerning this correspondence may be made to me at the numberlisted below or the address on this letterhead. Re.s~~ ~ Building Systems Consultant (920) 236-5051 Monday-Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required Fee Received Balance Due $ $ $ 390.00 390.00 0.00 .J:\Jnspcctiolls\Fian Plan RGvit~\~' 100T)( r ",1 g7S...0 1 07550 S l<'t)o'fier St Bklg Page 2 of2