HomeMy WebLinkAbout012154 / Electric e eSHKOSH ON THE WATER Issue Date 1/11/2007 Address 315 ALGOMA BLVD INSPECTION SERVICES DIVISION ROOM 205 DEPARTMENT OF COMMUNITY DEVELOPMENT CORRECTION NOTICE CITY OF OSHKOSH 215 CHURCH AVE PO Box 1130 OSHKOSH WI 54903-1130 Compliance Date 2/1 0/2007 IMMEDIATELY Compliance No Sent to ~ Owner Name ! WIS BELL INC Address 722 N BROADWAY ST City MILWAUKEE State Zip Code WI 53202 -4396 Introduction U Required for Occupancy Occupancy Commercial hile conducting Final Inspection with Glen from Eland Electric the following violation was noted that a Correction Notice was requested for. Other violations will be corrected when the final installations are completed. Item # 1 Description Code NEC 250.30(A)(3) Compliance No Compliance Date 02/10/2007 IMMEDIATELY grounding electrode conductor for a separately derived system shall be sized in accordance with 250.66 for the derived phase conductors nd shall be used to connect the grounded conductor to the grounding electrode. Note: See the atached document which describes the NEC's nterpretation of a separately derived system. This is a copy from the commentary of NFPA 70 / NEC. 01/11/2007 Last Updated Summary TO avoid any further inconvenience please correct the above noted violation immediately. Any questionsorconcerns please eel free to contact me @ 920-236-5046 or email @ kbenner@cLoshkosh.wLus Violations must be corrected and approved within 30 days unless otherwise noted. Call for r~inspections prior to concealment and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 2/10/2007 Office hours for obtaining permits are Monday through Friday 7:30-8:30 a.m. and 12:30-1 :30 p.m. or by appointment. To schedule inspections please call the Inspection Request line at 236-5128 noting the address, permit number (when applicable), and the nature of what needs to be inspected. S'gnatu", ~t:3 B<l4'1~ D""'~ Inspecte Y: Kevin Benner 236-5046 kbenner@ci.oshkosh.wi.us I hereby certify the violations listed on this report have been corrected In compliance with the applicable codes. Print Name Company Signature Date Also Sent to: U Bldg ~ Elec U HVAC U Plbg U Designer U Other U Inspector I j ELAND ELECTRIC CORP I i i -l I 3154 HOLMGREN WAY GREEN BAY WI 54304 -0 12154 Page 1 of 1 '.' .. Section 250.30(A) provides the requirements for bonding and grounding the separately derived systems described in 250.20(D). A separately derived system is defined in Article 100 as a premises wiring system in which power is derived from a battery, a solar photovoltaic system, a generator, a transformer, or converter windings. It has no direct electrical connection, including a solidly connected grounded circuit conductor, to supply conductors originating in another system. The requirements of 250.30 are commonly applied to 480-volt transformers that transform a 480-volt supply to a 208Y1120-volt system for lighting and appliance loads. These requirements provide for a low-impedance path to ground so that line-to-ground faults on circuits supplied by the transformer result in a sufficient amount of current to operate the overcurrent devices. These requirements also apply to generators or systems that are derived. from converter windings, although these systems do not have the same wide use as separately derived systems that are derived from transformers.