Loading...
HomeMy WebLinkAbout0122897-HVAC e OSHKOSH ON THE WATER Job Address 3596 STEARNS DR CITY OF OSHKOSH No 122897 HVAC PERMIT -APPLICATION AND RECORD Owner DANIEL E DOWLING Create Date 12/14/2006 Contractor GARTMAN MECHANICAL SERVICES Fuel ~ Gas UOil System ~ New l!:J Forced Air U Radiant U Electric U Hot Water Chimney Type U Chimney A . Chimney B Heat Loss . As Approved o Existing BTU Rate . As Per Plan () Variable Category 510 - Ind. & Comm-Heating & Ventilating U Solar Plan Q5-85-0905-R2H U Solid U Electric D Replace U Steam U Suppl. () Direct Vent U AlC U Con. Burner l () Not Applicable o Not Applicable () Other Value Value Use/Nature IND/ Installation of 5 unit heaters as per plans. of Work Fees: Valuation $10,900.00 Plan Approval $0.00 Permit Fee Paid $169.00 Issued By: Date 12/14/2006 D Permit Voided I Parcel Id # 1278800000 In the performance of this work, I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date AgenUOwner Address PO BOX 2264 OSHKOSH WI 54903 - 2264 Telephone Number (920) 231-5530 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. Oct OS 04 09:52a .Oshkosh Inspections 920-236-5084 p. 1 'f ,. r City of Oshkosh Division ofInspection Services P.O. Box 1130 Oshkosh, WI 54903-1130 Phone (920) 236-5050 Fax (920) 236-5084 HVAC PERMIT APPLICATION All information after bold categories must be provided. Incomplete applications will not be processed. ~ OfHKOfH ON THE WATER · Application(s) and fee(s) can be brought to City Hall, Room 205 or mailed to Inspection Services, PO Box 1128, Oshkosh WI 54903-1128. Commencing work without permit(s) win result in fees being doubled or $100.00 plus the normal pennit fee, which ever is greater. OR I au are a contractor artici otin in the Permit ee Account S stem and have ade uate :~~~~::?;;;o;;:~: X /~;;j~. ~dj OWNER ~~ ?d.cif_ jpMd-'l' 'CONTRAcrOR ,~~~ C- .. CHECK It!' ALL APPLICABLE r\i USE CATEGORY OSingle Family DDuplex OMulti-Family FUEL ~s ORental ~mmercial o Industrial DElectric DSolid o Solar SYSTEM DNew o Other OReplace ~~ed Air DRadiant DSteam DAlC OVent DElectric OHot Water OSuppL Oeon. Burner IS CHIMNEY BEING LINED~o DYes - LINER SIZE & MANUFACTURER Note: All chimneys shall be sized ~th~'BTU's being vented. CHIMNEY TYPE ~'mneY A DChinmey B BEAT LOSS . Approved OExisting BTU RATE s Per Plan DVariable DESCRIPTION OF AI.. WORK BEING DO ~.'O ODirect Vent OOther DNot Applicable DOther Value \0, cPy $ /L?.J 90a VALUE ELECTRICAL CONTRACTOR o For applicable projects, an Electric Installation Verification fonn, signed by the Electrical Contractor, must be attached. If not attached or not applicable, a separate Electrical Permit is required. ---- {\ t 9(02 Job Address 3596 STEARNS DR HVAC Permit Work Card Permit Number : 122897 Create Date 12/14/2006 Contractor GARTMAN MECHANICAL SERVICES Owner DANIEL E DOWLING Fuel [~Gas I U Oil U Electric 1 U Solar System 0 New I 0 Replace ~ Forced Air U Radiant I U Steam U Electric U Hot Water I U Suppl. Chimney Type 0 Chimney A . Chimney B Use/Nature IND/. Installation of 5 unit heaters as per plans. of Work I ~n Value I 0 Other ~ U AlC ~ U Vent I ~Con. Burner I . o Direct Vent . 0 Not Applicable $10,900.00 I I Inspections: Date 11/7/2007 Type Final Inspector Allyn Dannhoff not approved Need properly located thermostats and provide thermostats with automatic setback controls. Need HVAC Compliance Statement. . Date/Time requested: Access: I Requested By: o Reinspect Fee 0 Fee Waived Notice Type: R~ady DatefTime: Phone Number: o Reinspect Fee Paid - - - - - - - - - - - - -- - - - - - - --- - - - - - - - - - - - - - - - - - - - - - - --- - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - -- Date 12/31/2007 Type Final Inspector Allyn Dannhoff hermostats corrected per e-mail from Tim Weitz (Gartman). approved w/cond. Date/Time requested: Access: I Requested By: o Reinspect Fee 0 Fee Waived Notice Type: R~ady DatefTime: Phone Number: o Reinspect Fee Paid - - - -_.- - -- - ------ - - --- _.-- - - -- -_.- -- - ----- - - --- ---- - -- - .------ - - ---- ------ - - - ---- -- - ---- -. - - - - - - - - - .--- - -- ---- - - - - ---- -------- ------ - - ----- ---- --- ------- - - ---- ------ -- - ----- ~'~,""- :,~.?io-:.;:~.;.;~~~~~,...."_. ".,..:::;;:..;;.:....~...,- ~ OJHKOfH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.cLoshkosh.wi.us ON THE WATER December 14, 2006 Keith Paul OMS Inc 520 W South Park Ave Oshkosh, WI 54902 Dan Dowling' 3596 Sterns Dr. Oshkosh WI 54903 Site: Plan Number: Q5-85-0905-R2 -H 3596 Sterns Dr Oshkosh WI 54901 For: Description: HV AC for Sunset School Conversion Object Type: HV AC Only Building Type: VB - 5422 Sq. Ft. Unsprinklered Occupancy:Sl,S2,:Storage The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPR,OVED. The owner, as defined in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) I Conditions: . IBC 1101.21ANSI A117.1-308.2 & 3 -Mechanical system controls shall be located a maximum of 48" above the finished floor if the floor space allows a forward approach by a wheel chair or if the clear space allows a parallel approach. . 304.4 Public garages. Appliances located in public garages, service stations, repair garages or other areas frequented by motor vehicles, shall be installed a minimum of 8 feet (2438 mm) above the floor. Where motor vehicles exceed 6 feet (1829 rom) in height and are capable of passing under an appliance, appliances shall be installed a minimum of2 feet (610 rom) higher above the floor than the height of the tallest vehicle. . IFGC 401 /Comm 65.0400 All gas piping and gas piping installations shall comply with NFP A 54, National Fuel Gas Code. . IFGC 619.2 Support. Suspended-type unit heaters shall be supported by elements that are designed and constructed to accommodate the weight and dynamic loads. Hangers and brackets shall be of noncombustible material. . 619.4 Clearance. Suspended-type unit heaters shall be installed with clearances to combustible materials of not less than 18 inches (457 rom) at the sides, 12 inches (305 rom) at the bottom and 6 inches (152 mm) above the top where the unit heater has an internal draft hood or 1 inch (25 rom) above the top of the sloping side of the vertical draft hood. Exception: Unit heaters listed for reduced clearance shall be permitted to be installed with such clearances in accordance with their listing and the manufacturer's instructions. f:\fn"fI,,\,;ions\Plan Pevit'w'-C\llTlrne:','i,!i I'bn i<e,"'\'w::n\)6'Q5-85-o905-1n~1l 3596 Sfe,.,,, 'f)r I IV AC (lniy,d,,\' Page 1 of2 .....~~.-....-- ~ . .Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules. under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Corom 61.31(1). A copy of the approved plans, specifications, and this letter shall be on-she during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead. a Building Systems Consultant (920) 236-5045 Monday- Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M. adannhoff@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 320.00 320.00 0.00 " Rcvi!:w\('O!Hmer'-';11 !(;C'\">'\' "I)!jli"Q5-85-0905-RI-Il 35% SW'1';' I), IIVAC Only,deK' Page 2 of2 ~. "-~,...~,..~"_..,,,.. ~ ~."."..-.. ~~~_ n"_~" ~ CORRECTION NOTICE / FIELD INSPECTION REPORT JOB LOCATION: .3S'"?(P ~eo t- i'\.:'S: CONTRACTOR: OW)l^-€r- / c;.,:n-f-i4A-a let ./ PROJECT TO BE INSPECTED: #'?h~f'~ .Q..- s: Lob TYPE OF INSPECTION: ;:=r'A-CL r / ~ City of Oshkosh Inspection Services Division 215 Church Avenue, PO Box 1130 Oshkosh, WI 54903-1130 Phone: (920) 236-5050 Fax (920) 236-5084 a.r-€.A- Violations must be corrected and approved within 30 days unless otherwise noted. Call for re-inspections prior to concealment and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice and return it to the Inspection Services Division by the Compliance Date of 1 ~ l .ct'lll'Mf#. ""OODE INSPECnONRESULTS ~l1ed/Faxed Z~-~~d---- Phone # Print Name Company Date Signature: Page 1 of 1 Dannhoff, Allyn J. From: Tim Weitz [tweitz@gartmanmechanical.com] Sent: Friday, December 14, 20078:00 AM To: Dannhoff, Allyn J. Subject: Dowling's Allyn, We have completed the services required in the correction notice for Dowling's building however I am waiting on the signature from Dan that you requested. He was not present upon completion of the services, I will send through the paperwork when he returns the signed copy to us. Thank you for the extension on these services, if you have any questions or concerns please give me a call. Tim Weitz GMS, Inc. 12/14/2007