Loading...
HomeMy WebLinkAboutHVAC Plan Approval ,."~""; ~ OJHKOfH City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.ci.oshkosh.wi.us ON THE WATER December 14,2006 Keith Paul GMS Inc 520 W South Park Ave Oshkosh, WI 54902 Dan Dowling 3596 Sterns Dr. Oshkosh WI 54903 Site: Plan Number: Q5-85-0905-R2-H 3596 Sterns Dr Oshkosh WI 54901 For:' Description: HV AC for Sunset School Conversion Object Type: HV AC Only Building Type: VB - 5422 Sq. Ft. Unsprinklered Occupancy: SI, S2, :Storage The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements Key Item(s) I Conditions: . IBC 1l01.2/ANSI A1l7.1-308.2 & 3 - Mechanical system controls shall be located a maximum of 48" above the finished floor if the floor space allows a forward approach by a wheel chair or if the clear space allows a parallel approach. . 304.4 Public garages. Appliances located in public garages, service stations, repair garages or other areas frequented bv motor vehicles, shall be installed a minimum of 8 feet (2438 mm) above the floor. Where motor vehicles exceed 6 feet (1829 mm) in height and are capable ofpassirig under an appliance, appliances shall be installed a minimum of2 feet (610 mm) higher above the floor than the height of the tallest vehicle. . IFGC 401/Comm 65.0400 All gas piping and gas piping installations shall comply with NFP A 54, National Fuel Gas Code. . IFGC 619.2 Support. Suspended-type unit heaters shall be supported by elements that are designed and constructed to accommodate the weight and dynamic loads. Hangers and brackets shall be of noncombustible material. . 619.4 Clearance. Suspended-type unit heaters shall be installed with clearances to combustible materials of not less than 18 inches (457 mm) at the sides, 12 inches (305 mm) at the bottom and 6 inches (152 rom) above the top where the unit heater has an internal draft hood or 1 inch (25 mm) above the top of the sloping side of the vertical draft hood. Exception: Unit heaters listed for reduced clearance shall be permitted to be installed with such clearances in accordance with their listing and the manufacturer's instructions. r:'.Jn,pe<:l;,m,'.P!an FeVleW\('OrlHnt:,.,,'ni Pi,lll 1<,:",<"," i'.f\)6\Q5-85~9(l5-R2~[J 3:'96 Stern, Dr IIV (lniy,dn<: Page 1 of2 . Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code, and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized representative prior to the work involved in the revision or modification being carried out; A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm 61.31(1). A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence maybe made to me at the number listed below or the address on this letterhead. Building Systems Consultant (920) 236-5045 Monday-Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M, adannhoff@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 320.00 320.00 0.00 i!n,pedi',lHs\Phm Review\Commerc'i,,: I'Lm (<C" ','W ~,(;()Ii'{)5-85-()9(l5-R2-H 35% Sle"''' Dr IIV!\C Oniy,do<: Page 2 of 2