November 01,2005
CUST ID No. 646685
AITN: Buildings & Structures Inspector.
MARK C ROHLOFF
UTSCHIG IMPERIAL BUILDING SYSTEMS
N1040 CRAFTSMAN DR
GREENVILLE WI 54942
BUILDING INSPECTION
CITY OF OSHKOSH
POB 1130
OSHKOSH WI 54902
CONDITIONAL APPROVAL
PLAN APPROVAL EXPIRES: 11/0112007
SITE:
Orion Flight Services
3418 Park Drive
City of Oshkosh
FOR:
Object Type: Building ICC Regulated Object ID No.: 1043135
Major Occupancy: Storage; Type IIB Metal Frame Unprotected class of construction; New plan;
Occupancy: S-l Storage Moderate-Hazard
Identification' Numbers
Transaction ID No. 1200747
Site ID No. 705529
Pleaserefert9R?th. identWcati8J.1.l1tlrr9~;S,..
above, in all corres ondence.with th~a enc,'
12,000 project sq ft;
The submittal described above has been, reviewed for conformance with applicable WiSConsin Administrative Codes
and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in
chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements.
The following conditions shall be met during construction or installation and prior to occupancy or use:
Key Item(s)
. IBC 1003.3.3.3 If deck above the toilet room is used for general storage, a standard exit stair & handrails shall
be provided. Guards shall be provided around the mezzanine. All stairs shall have a minimum rise of 4". For
public stairs, risers shall be not more than 7 inches with a minimum tread of 11 inches. Treads and risers shall
be uniform in any flight of stairs.
. IBC 412.2.6 Aircraft hangars shall be provided with fire suppression as required per NFP A 409.
Submit
. Comm 61.30(3) This review does not include heating, ventilating or air conditioning. The owner should be
reminded that HVAC plans, calculations, and appropriate fees are required to be submitted for review and
approval prior to installation. The submitted HV AC plans shall match the approved building plans.
. Submit, prior to installation, one (1) set of properly signed and sealed metal building plans, a completed SB-118
application form including this transaction number and signed by the building designer, and $100 submittal fee
to Safety& Buildings, P.O. Box 7162, Madison WI 53707-7162.
Reminders
. Comm 61.30(3) This review does not include lighting. Comm 63.0001 Prior to installation, lighting plans and
ca1culationsshall be prepared in compliance with the code and properly signed and sealed. The plans'stuilIbt'"
available at the job site as requested by the Department representative or local official.
. IBC 1003.2.10 Provide exit, exit access doors, and egress stairways with exit signs and directional exit signs in
compliance with this section. Address the need for 90 minute continued illumination in case of power loss.
MARK C ROHLOFF
Page 2
111112005
. me 1003.2.11 Provide emergency illumination power in egress paths per this section. Each interior exit area
designated in the code shall be addressed. In addition, each of the exterior exit discharge areas adjacent to exit
discharge doorways shall be addressed if two or more exits are required.
A copy of the approved plans, specifications and this letter shall be on-site during construction and open to
inspection by authorized representati ves of the Department, which may include local inspectors. If plan index sheets
were submitted in lieu of additional full plansets, a copy of this approval letter and index sheet shall be attached to
plans that correspond with the copy on file with the Department. All permits required by the state or the local
municipality shall be obtained prior to commencement of construction/installation/operation.
In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions should
conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review
shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address
on this letterhead.
Fee Requir:ed $
Fee Received $
Balance Due $
820.00
820.00
0.00
Plan Reviewer, Integrated Services
(920)492-5606 , M-t 6:30 am - 4:00 pm, Fri a.m. Only
ddiedrick@commerce.state.wi.us
cc: Peter R Ochs, Building Inspector, (920) 948-3500 , Friday, 7:45 A.M. - 4:30 P.M.
Jeff Wanke, Orion Flight Services
.. j commerce.wi.gov
~i!E.9!l~!!
Safety and Buildings
PO BOX 7162
MADISON WI 53707-7162
TDD #: (608) 264-8777
www.commerce.wi.gov/sb/
www.wisconsin.gov
Jim Doyle, Governor
Mary P. Burke, Secretary
January 10,2006
CUST ID No. 646685
ATTN: Buildings & Structures Inspector
MARK. C ROHLOFF
UTSCHIG IMPERIAL BUILDING SYSTEMS
NI040 CRAFTSMAN DR
GREENVILLE WI 54942
BUILDING INSPECTION
CITY OF OSHKOSH
POB 1130
OSHKOSH WI 54902
COMPONENT RECEIVED
SITE:
Orion Flight Services
3418 Park Drive
City of Oshkosh
FOR:
Object Type: Metal Building Regulated Object ID No.: 1057727
The department has received the above component plan indicated as being reviewed for compliance with the general
design concept and submitted by the building designer named above. The Department has filed the plans and other
related documents.
The department will rely on, and hold responsible, the building design professional and/or supervising professional
of record for compliance with the rules. The responsible professional should particularly insure that proper loads
and fire resistive rating have been incorporated to correspond to the building design. Particularly insure: proper dead
and live loading, including snow drift loading increases, unbalanced loads, equipment loads, proper
bearing/supports, concentrated loads etc, are properly conveyed to foundations; and that required fire ratings have
been employed.
The submitted materials have not been reviewed by the Department for compliance with all applicable administrative
rules. The department reserves the right to formally review the plans in the future if the department determines that
such a review is warranted, and to order corrective actions with respect to the outcome of that review.
A copy ofthe plan that is identical to the plan submitted for our file shall be available for inspection at the job
site. When the total building volume exceeds 50,000 cubic feet, the plan shall bear an indication of review that has
been signed or initialed by the building designer of record.
Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address
on this letterhead. Please refer to Transaction ID No. referred to in the regarding line when making an inquiry or
submitting additional information.
Sincerely,
Fee Required $
Fee Received $
Balance Due $
100.00
100.00
0.00
Jean M MacCubbin
Engineering Consultant, Integrated Services
(608) 266-0955, Fax: (608) 267-9566 , M - F: 700 am - 330 pm
jmaccubbin@commerce.state.wi.us
cc: Peter R Ochs, Building Inspector, (920) 948-3500 , Friday, 7:45 A.M. - 4:30 P.M.
......- j, commerce.wi.gov
"'U.J !!tJa9!l~.Q
Safety and Buildings
2331 ,SAN LUIS PL STE 15~
GREEN BAY WI 54304
TDD #: (608) 264-8777
www.commerce.wi.gov/sb/
www.wisconsin.gov .
RECEIVED
Jim Doyle, Governor
Mary P. Burke, Secretary
January 18,2006
Addendum to plan examination letter of November 1, 2005
SITE:
Orion Flight Services
3418 Park Drive
City of Oshkosh
FOR:
Object Type: Building ICC Regulated Object ID No.: 1043135
Major Occupancy: Storage; Type lIB Metal Frame Unprotected class of construction; New plan; 12,000 project sq ft;
Unsprinklered; Occupancy:S-l Storage Moderate-Hazard; Component(s) submitted with this transaction: Metal
Building, HV AC ICC; Allowable area determined by: Unseparated Use
. Identification Numbers
Transaction ID No. 1200747
Site ID No. 705529
Pleas~ refer to both identification numbers,
abov~, in all corresondence with the a em;
. As per documentation from the submitter and owner stating that no hazardous operations will take place in this
building, and that the bi - fold door has an access opening height of 27', the following code requirement specified
in the plan examination letter is NOT required.
-!Be 412.2.6 Aircraft hangars shall be provided with fire suppression as required per NFPA 409.
Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address
on this letterhead. Please refer to Transaction ID No. referred to in the regarding line when making an inquiry or
submitting additional information.
1Jr/IJ~
Donald L Diedrick
Plan Reviewer, Integrated Services
(920)492-5606, M-t 6:30 am - 4:00 pm, Fri a.m. Only
ddiedrick@commerce.state.wi.us
cc: Peter R Ochs, Building Inspector, (920) 948-3500, Friday, 7:45 A.M. - 4:30 P.M.
Building Inspection City of Oshkosh, 920/236-5051
Jeff Wanke, Orion Flight Services