Loading...
HomeMy WebLinkAboutPLAN APPROVAL BUILDING "1 commerce.wi.gov ~ l!!~9.Q!lt'! c ~', l' C, Safety and Buildings 2331 SAN LUIS PL STE 150 GREEN BAY WI 54304 TOO #: (608) 264-8777 www.commerce.wLgov/sb/ www.wisconsin.gov NOV 0 3 2005 ui:rf\ii.1 iviEiiTGr ('()M~\riU: ',,~,jj'iT'V 'D1LH,lr;:l,~,>:,~r.:\ilI~T, t,..F .,"~'~'~"~B ili.. u. [..i1t_ u!rlEf~U1v Jim Doyle, Governor Mary P. Burke, Secretary November 01,2005 CUST ID No. 646685 AITN: Buildings & Structures Inspector. MARK C ROHLOFF UTSCHIG IMPERIAL BUILDING SYSTEMS N1040 CRAFTSMAN DR GREENVILLE WI 54942 BUILDING INSPECTION CITY OF OSHKOSH POB 1130 OSHKOSH WI 54902 CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 11/0112007 SITE: Orion Flight Services 3418 Park Drive City of Oshkosh FOR: Object Type: Building ICC Regulated Object ID No.: 1043135 Major Occupancy: Storage; Type IIB Metal Frame Unprotected class of construction; New plan; Occupancy: S-l Storage Moderate-Hazard Identification' Numbers Transaction ID No. 1200747 Site ID No. 705529 Pleaserefert9R?th. identWcati8J.1.l1tlrr9~;S,.. above, in all corres ondence.with th~a enc,' 12,000 project sq ft; The submittal described above has been, reviewed for conformance with applicable WiSConsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. The following conditions shall be met during construction or installation and prior to occupancy or use: Key Item(s) . IBC 1003.3.3.3 If deck above the toilet room is used for general storage, a standard exit stair & handrails shall be provided. Guards shall be provided around the mezzanine. All stairs shall have a minimum rise of 4". For public stairs, risers shall be not more than 7 inches with a minimum tread of 11 inches. Treads and risers shall be uniform in any flight of stairs. . IBC 412.2.6 Aircraft hangars shall be provided with fire suppression as required per NFP A 409. Submit . Comm 61.30(3) This review does not include heating, ventilating or air conditioning. The owner should be reminded that HVAC plans, calculations, and appropriate fees are required to be submitted for review and approval prior to installation. The submitted HV AC plans shall match the approved building plans. . Submit, prior to installation, one (1) set of properly signed and sealed metal building plans, a completed SB-118 application form including this transaction number and signed by the building designer, and $100 submittal fee to Safety& Buildings, P.O. Box 7162, Madison WI 53707-7162. Reminders . Comm 61.30(3) This review does not include lighting. Comm 63.0001 Prior to installation, lighting plans and ca1culationsshall be prepared in compliance with the code and properly signed and sealed. The plans'stuilIbt'" available at the job site as requested by the Department representative or local official. . IBC 1003.2.10 Provide exit, exit access doors, and egress stairways with exit signs and directional exit signs in compliance with this section. Address the need for 90 minute continued illumination in case of power loss. MARK C ROHLOFF Page 2 111112005 . me 1003.2.11 Provide emergency illumination power in egress paths per this section. Each interior exit area designated in the code shall be addressed. In addition, each of the exterior exit discharge areas adjacent to exit discharge doorways shall be addressed if two or more exits are required. A copy of the approved plans, specifications and this letter shall be on-site during construction and open to inspection by authorized representati ves of the Department, which may include local inspectors. If plan index sheets were submitted in lieu of additional full plansets, a copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file with the Department. All permits required by the state or the local municipality shall be obtained prior to commencement of construction/installation/operation. In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Fee Requir:ed $ Fee Received $ Balance Due $ 820.00 820.00 0.00 Plan Reviewer, Integrated Services (920)492-5606 , M-t 6:30 am - 4:00 pm, Fri a.m. Only ddiedrick@commerce.state.wi.us cc: Peter R Ochs, Building Inspector, (920) 948-3500 , Friday, 7:45 A.M. - 4:30 P.M. Jeff Wanke, Orion Flight Services .. j commerce.wi.gov ~i!E.9!l~!! Safety and Buildings PO BOX 7162 MADISON WI 53707-7162 TDD #: (608) 264-8777 www.commerce.wi.gov/sb/ www.wisconsin.gov Jim Doyle, Governor Mary P. Burke, Secretary January 10,2006 CUST ID No. 646685 ATTN: Buildings & Structures Inspector MARK. C ROHLOFF UTSCHIG IMPERIAL BUILDING SYSTEMS NI040 CRAFTSMAN DR GREENVILLE WI 54942 BUILDING INSPECTION CITY OF OSHKOSH POB 1130 OSHKOSH WI 54902 COMPONENT RECEIVED SITE: Orion Flight Services 3418 Park Drive City of Oshkosh FOR: Object Type: Metal Building Regulated Object ID No.: 1057727 The department has received the above component plan indicated as being reviewed for compliance with the general design concept and submitted by the building designer named above. The Department has filed the plans and other related documents. The department will rely on, and hold responsible, the building design professional and/or supervising professional of record for compliance with the rules. The responsible professional should particularly insure that proper loads and fire resistive rating have been incorporated to correspond to the building design. Particularly insure: proper dead and live loading, including snow drift loading increases, unbalanced loads, equipment loads, proper bearing/supports, concentrated loads etc, are properly conveyed to foundations; and that required fire ratings have been employed. The submitted materials have not been reviewed by the Department for compliance with all applicable administrative rules. The department reserves the right to formally review the plans in the future if the department determines that such a review is warranted, and to order corrective actions with respect to the outcome of that review. A copy ofthe plan that is identical to the plan submitted for our file shall be available for inspection at the job site. When the total building volume exceeds 50,000 cubic feet, the plan shall bear an indication of review that has been signed or initialed by the building designer of record. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Please refer to Transaction ID No. referred to in the regarding line when making an inquiry or submitting additional information. Sincerely, Fee Required $ Fee Received $ Balance Due $ 100.00 100.00 0.00 Jean M MacCubbin Engineering Consultant, Integrated Services (608) 266-0955, Fax: (608) 267-9566 , M - F: 700 am - 330 pm jmaccubbin@commerce.state.wi.us cc: Peter R Ochs, Building Inspector, (920) 948-3500 , Friday, 7:45 A.M. - 4:30 P.M. ......- j, commerce.wi.gov "'U.J !!tJa9!l~.Q Safety and Buildings 2331 ,SAN LUIS PL STE 15~ GREEN BAY WI 54304 TDD #: (608) 264-8777 www.commerce.wi.gov/sb/ www.wisconsin.gov . RECEIVED Jim Doyle, Governor Mary P. Burke, Secretary January 18,2006 Addendum to plan examination letter of November 1, 2005 SITE: Orion Flight Services 3418 Park Drive City of Oshkosh FOR: Object Type: Building ICC Regulated Object ID No.: 1043135 Major Occupancy: Storage; Type lIB Metal Frame Unprotected class of construction; New plan; 12,000 project sq ft; Unsprinklered; Occupancy:S-l Storage Moderate-Hazard; Component(s) submitted with this transaction: Metal Building, HV AC ICC; Allowable area determined by: Unseparated Use . Identification Numbers Transaction ID No. 1200747 Site ID No. 705529 Pleas~ refer to both identification numbers, abov~, in all corresondence with the a em; . As per documentation from the submitter and owner stating that no hazardous operations will take place in this building, and that the bi - fold door has an access opening height of 27', the following code requirement specified in the plan examination letter is NOT required. -!Be 412.2.6 Aircraft hangars shall be provided with fire suppression as required per NFPA 409. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Please refer to Transaction ID No. referred to in the regarding line when making an inquiry or submitting additional information. 1Jr/IJ~ Donald L Diedrick Plan Reviewer, Integrated Services (920)492-5606, M-t 6:30 am - 4:00 pm, Fri a.m. Only ddiedrick@commerce.state.wi.us cc: Peter R Ochs, Building Inspector, (920) 948-3500, Friday, 7:45 A.M. - 4:30 P.M. Building Inspection City of Oshkosh, 920/236-5051 Jeff Wanke, Orion Flight Services