HomeMy WebLinkAboutHVAC PLAN APPROVAL """'- j commerce.wLgov ~i!~9on!JJ:! Safety' and Buildings 31 SAN LUIS PL STE 150 GREEN BAY WI 54304 TOD #: (608) 264-8777 www.commerce.wi.gov/sb/ www.wisconsin.gov ..- OCT J 1 2005 COMM~~1~n~1ENT OF DEVELOPMEtvr Jim Doyle, Governor Mary P. Burke, Secretary October 27, 2005 CUST ID No. 259120 ARTHUR WARREN CONDON TOTAL COMFORT INC 11 BLACKBURN ST PO BOX 184 RIPON WI 54971 A TTN: Buildings & Structures Inspector BUILDING INSPECTION CITY OF OSHKOSH POB 1130 OSHKOSH WI 54902 CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 10/27/2006 SITE: Jay Manufacturing 2045 W 20TH St City of Oshkosh, 54901 FOR: Object Type: HV AC ICC System 38,980 sq ft Area Heated Identification Numbers Transaction ID No. 1203483 Site ID No. 702703 Please refer to both identification numbers, above, in all corres ondence with the a enc . Regulated Object ID No.: 1045372 The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in chapter 101.01 (10), Wisconsin Statutes, is responsible for compliance with all code requirements. The following conditions shall be met during construction or installation and prior to occupancy or use: Key Item(s) . IMC 304.4/IFGC 305.3/IBC 1607.7.3 Provide suspended heating appliances for public garages, service stations, repair garages or other motor vehicle areas at least8 feet above the floor, or a minimum of2 ft higher above the floor than the height of the tallest vehicle based on door opening height, whichever is greater; or provide protection from motor vehicle impact. All suspended equipment shall be protected per this code section. . IMC 403/Comm 64.0403 Provide minimum mechanical exhaust ventilation in the amount of 75 cfm per fixture for the public toilet rooms. See Comm Table 64.0403. Toilet room 06, located adjacent to the lobby shall be provided exhaust. Plans indicate no fan in, this toilet room. . IMC 306.5/IFGC 306.5 Provide a permanent access for appliances installed on roofs or elevated structures with equipment located at a height exceeding 16 ft. Access shall not require climbing over obstructions greater than 30 inches, or walking on roofs having a slope greater than 4/12. Permanent access shall be provided,to RTU-1 and RTU-2 on the roof of the addition building. A copy of the approved plans, specifications and this letter shall be on-site during construction and open to inspection by authorized representatives of the Department, which may include local inspectors. If plan index sheets were submitted in lieu of additional full plansets, a copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file with the Department. All permits required by the state or the local municipality shall be obtained prior to commencement of construction/installation/operation. In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component.