Oct 12,2005
Keith Paul
Gartman Mechanical
520 W South Park Ave
Oshkosh WI 54903
James Petr
Milwukee P.C.
3900 N Shoreburn Plaza
Shorewood WI 53211
Site: Plan Number: P4-46-0705-H
Lindekugel's Salon
1024 W 20th Ave
Oshkosh WI 54902
For:
Description: HV AC system for Tenant space alterations
Object Type: HV AC only .
Class of Construction: IDB - 2100 Sq Ft.; Unsprinklered
Occupancy: B: Business
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Item(s) / Conditions:
. IMC 302.1 The building or structure shall not be weakened by the installation of mechanical systems. Per
letter from Bill Montelbano dated 10/7/05 the structure is adequate for equipment - additional
evaluation is required for any screening
. IMC 403.3 [Comm 64.0403 (6)] Ventilation rate. Janitor closets. A janitor closet thathas only one
service sink may be provided with either natural ventilation via a window or louvered opening with at least
2 square feet (0.2 m2) of area openable directly to the outside or mechanical exhaust ventilation as
specified in Table 64.0403. Per discussion with Keith Paul- additional exhaust will be provided in this
area.
. IFGC 304.2 Appliance/equipment location. Equipment shall be located so as not to interfere with proper
circulation of combustion, ventilation, and dilution air. Caution on location of water heater in room with
dryer and exhaust grill-lfwater heater is not an electric, or sealed combustion unit additional
combustion air may be required. (
. MUN 30-35 (1)(5) All roof top and ground level mechanical equipment and utilities shall be fully screened
from view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236-
5062 for additional information on screening requirements. All screening shall be properly anchored in
place to resist wind loads. Additionally mc 1608.8 Roofprojections - Drift loads due to mechanical
equipment, penthouses, parapets and other projections above the roof shall be determined in accordance
with Section 7.8 of ASCE 7. Per letter from Jim Petr dated 9/2/05 the required screening will be
completed by December 31,2005. Plans are required to be submitted and approved prior to
installation.
II:\hdann\10D5. Cornm !>;:~l';
J024W 2\itn A\" R,,\ IIV AC Oniy.d'\(:
Page 1 of2
fII.....-...
...
SUBMIT:
. IEce 503.3.3.7 [Comm 63.0503(2)(1)] Balancing and documentation of the HV AC system shall conform
to the !MC. Balancing report required to be submitted prior to final occupancy being allowed.
. Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead.
~
Brian Noe
Building Systems Consultant
(920) 236-5051 Monday - Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
II:\brjann<?,n(j:~ Comm Ph.m Revit~ws\P4-46-{)70:'::-,n ~V24 V/ l(;th Ave ,Rev nVA.C OnJy.diK:
Fee Required $
Fee Received $
Balance Due $
Page 2 of2
230.00
230.00
0.00
~
OJHKOfH
City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903-1130
www.cLoshkosh.wi.us
ON THE WATER
July 15,2005
Bill Montelbano
8 East Hudson St
Mazomaine WI 53560-0123
James Petr
Milwukee P.C.
3900 N Shoreburn Plaza
Shorewood WI 53211
Site: Plan Number: P4-46-0705
Lindekuge1's Salon
1024 W 20th Ave
Oshkosh WI 54902
For:
Description: Tenant space alterations
Object Type: Building only
Class of Construction: 11m - 2100 Sq Ft.; Unsprinklered
Occupancy: B: Business
Maximum No of Occupants: 21
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
NOTE: If the use of this space is changed to an "M" Occupancy, based on Table 1003.2.2.2, the occupant count
would be 70, this would result in an additional restroom being required, as Comm 62.2904(4) only allows for a
single restroom with a maximum of 50 persons.
Key Hem(s) / Conditions:
· IBC 906.1 / IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet.
· IBC 1003.2.10 Exit signs are required to be installed per thIS section
· IBC 1003.2.11 Means of egress illumination is required to be installed per this section
· IBC 2902..1 / Table 2902 Drinking water is required to be 'provided, since no drinking fountain is shown
on plans a bottled water cooler is required to be provided.
· IMC 504 This section governs the installation of clothes dryers and there exhaust. Depending on the
manufactures listing for the dryer the maximum length exhaust duct for the dryer shall not exceed 25 feet.
· IMC This plan review does not include heating, ventilation, or air conditioning. HV AC plans
are required to be submitted and approved prior to installation ofHV AC equipment. Be aware
that mc 1004.3.2.4 contains additional restriction for ~ir movement in corridors
II:\brialln\2005 Comm Plan Reviews',P4-l6-0705 102.+ W 20th Ave .Bldg Only doc
Page 1 of2
. Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm 61.31(1).
SUBMIT:
. Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead.
Brian oe
Building Systems Inspector.