Loading...
HomeMy WebLinkAbout2006-Building (roof) e OSHKOSH ON THE WATER Job Address 820 WITZEL AVE CITY OF OSHKOSH No 120733 BUILDING PERMIT - APPLICATION AND RECORD Owner WIS TELEPHONE CO Create Date 07/25/2006 Designer CWS Source Inc Contractor W J WOODRUFF ROOFING CONTRACTORS It Category 210 - Addition Industrial Plan Type . Building o Sign o Canopy o Fence o Raze Zoning Class of Const: VB Size Unfinished/Basement Sq.Ft. Rooms Height Ft. D Projection I Finished/Living Sq.Ft. Bedrooms Stories Canopies Garage Sq.Ft. Baths Signs Foundation . Poured Concrete 0 Floating Slab o Concrete Block 0 Post o Pier 0 Other o Treated Wood Occupancy Permit Not Required Flood Plain No Height Permit Not Required Park Dedication Not Required # Dwelling Units o # Structures o UselNature of Work IND/ Tear-off roofing material down to existing structural wood deck consisting of tongue-and-groove plywood deck that complies with IBC section 2603.4.1.5, and install 1.5" of polyisocyanurate insulation followed by .5" woodfiber roof insulation, new EPDM rubber membrane, and flashing per manufactures specifications. HV AC Contractor Plumbing Contractor Electric Contractor $72,800.00 Plan Approval $0.00 Permit Fee Paid $317.00 Park Dedication Fees: Valuation $0.00 Issued By: Date 07/25/2006 Final/O.P. 00/00/0000 D Permit Voided I Parcel Id # 0609670000 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Address PO BOX 763 Agent/Owner FOND DU LAC WI 54936 - 0763 Telephone Number 920-922-3110 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (Le. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. 'b':JQ 821 . . 820 . . <b\:' . 804 815 xc: CWS SOURCE, INC. 12600 ROBIN LN. SUITE 100 BROOKFIELD, WI 53005 DATE: 07/24/06 NO.: 01 CONSTRUCTION BULLETIN PROJECT: RE-ROOFING 830 WITZEL AVE. OSHKOSH, WI PROJECT NO.: TO: DAN BUCHBURGER MARK WOODRUFF BRIAN NOE RE: mc COMPLIANCE GENERAL: This bulletin is issued to define the scope of revision in drawings and/or specifications for a contemplated change. The work required by these revisions shall be in accordance with the general requirements of the original contract documents. This bulletin is not a change order and work shall not be started without written authorization to proceed by Owner. The Contractor is requested to submit an itemized proposal for the revised work and identify the effect this change will have on construction cost and schedule if any. DESCRIPTION OF REVISION: The scope has been changed to indicate the compliance of the existing plywood deck with IBC 2603.4.1.5 as noted in section B.2.e : B. SCOPE OF WORK 1. Furnish and install specified roofing and related components to AT&T totaling approximately 12,444 square feet. 2. Work Includes: BASE BID - FULLY ADHERED, REINFORCED, EPDM RUBBER a. Roof areas 2 & 3 b. Removal and replacement of designated roofing and insulation. 1) Remove roofing and insulation down to structural wood deck, flashings to substrate. Note: Owner requests that Contractor take all precautions to reuse the existing gutter edge system, if possible. 2) Electrical heat tape system will be disconnected by others. Roofing contractor to remove heat tape system and reserve for re-installation on new roof system (See note below). c. Removal of Owner designated equipment and equipment supports. d. Localized substrate repair as required. e. Installation of the following over the existing, %" tongue and groove plywood deck (in compliance with IBC 2603.4.1.5): I) I-Layer of 1.5" Polyisocyanurate roof insulation. 2) I-Layer of .5" woodfiber roof insulation. 3) Crickets installed in designated areas 4) Rework existing drains. 5) Install new, reinforced EPDM rubber membrane, flashings and accessories per manufacturer's specifications. 6) Specified metal flashings and accessories. -;ij 7) Clean, prime and aluminize all existing sheet metal roof projections. 8) Install compatible walkway protection pads around all rooftop vent units. ATTACHMENTS: NONE ISSUED BY: Andy Angermeier CWS Source, Inc. Page 1 of2 Noe, Brian From: Noe, Brian Sent: Friday, July 21,20063:25 PM To: 'Mark A. Woodruff' Subject: RE: Roofing permit for 830 Witzel Ave Oshkosh NO - we can not issue a permit yet The document you sent does not address how you are complying with the thermal barrier requirements, and does nothing to tell us what the roof assembly is going to be. I contacted Ann Hanna, and discussed these issues with her, and she will be looking into this and providing me with additional information. Until I receive that information and have reviewed it, we are not able to issue a permit, and no work is permitted to begin. If you have any questions feel free to contact me. Brian Noe City of Oshkosh Building Systems Consultant (920) 236-5051 -----Original Message----- From: Mark A. Woodruff [mailto:woodruff@woodruffroofing.com] Sent: Friday, July 21, 2006 3:08 PM To: Noe, Brian Cc: Angermeier, Andy; Hanna, Ann E. Subject: Re: Roofing permit for 830 Witzel Ave Oshkosh Attached is the additional information you requested. Are we okay to start the project on Monday 7/24/06? Mark Woodruff 920-922-3110 W. J. Woodruff Roofing Contractors, Inc. POBox 763 Fond du Lac WI 54936-0763 W..wW~'\"LQQgruffr:QQflng,~Qm wood ruff@woodruffroofing.com ----- Original Message ----- From :NQ~LJ~Ii<?1l To: 'Mark A. Woodruff' Sent: Thursday, July 20, 2006 9:58 AM Subject: RE: Roofing permit for 830 Witzel Ave Oshkosh Thank you for the information, when we receive the additional information from the Owner, and have reviewed it we will process your permit application. No work is permitted to be done until a permit is issued. -----Original Message----- From: Mark A. Woodruff [mailto:woodruff@woodruffroofing.com] , 7/21/2006 Page 1 of2 Noe, Brian From: Mark A. Woodruff [woodruff@woodruffroofing.com] Sent: Friday, July 21, 2006 3:08 PM To: Noe, Brian Cc: Angermeier, Andy; Hanna, Ann E. Subject: Re: Roofing permit for 830 Witzel Ave Oshkosh Attached is the additional information you requested. Are we okay to start the project on Monday 7/24/06? Mark Woodruff 920-922-3110 W. J. Woodruff Roofing Contractors, Inc. POBox 763 Fond du Lac WI 54936-0763 www.woodruffroofing.com WQQQIlJIT@WQQQIYffCQolJOg,G9-fTI. ----- Original Message ----- From: Noe, Brian To: ~MgJ!s.A,YYooJ;!rlJff Sent: Thursday, July 20,20069:58 AM Subject: RE: Roofing permit for 830 Witzel Ave Oshkosh Thank you for the information, when we receive the additional information from the Owner, and have reviewed it we wi!! process your permit application. No work is permitted to be done until a permit is issued. -----Original Message----- From: Mark A. Woodruff [mailto:woodruff@woodruffroofing.com] Sent: Thursday, July 20, 2006 9:05 AM To:bnQ~@g,Q$hko$h,\,I\{LU$ Subject: Roofing permit for 830 Witzel Ave Oshkosh Brian: You asked for information concerning the reroofing work for the AT&T/SBC garage at 830 Witzel. The specification developed by the owner includes: 1- removing of the existing adhered EPDM roofing, roof insulation, and built-up roofing. 2- the new roof is a Johns Manville roof system SE6A consisting of a 1.5" polyiso ISO 3 insulation, a 1/2" fiberboard insulation mechanically attached with one fastener per two square feet to the plywood deck, then a fully adhered 60 mil reinforced EPDM membrane is fully adhered, at the existing gutter locations, new gutters are being installed, at the roof edge, the roof edge metal and a new metal fascia are being installed. No other modifications to the structure are specified. For FM & UL - ISO 3 is rated in Factory Mutual fire and wind-resistant systems for BUR, modified bitumen and single ply systems in specific constructions. It has been classified by UL as an approved roof insulation in many Class A roof constructions and Roof/Ceiling hourly fire-rated assemblies, and is classified by UL Canada. Since the roofing system specifications were designed by the owner, the information you requested for compliance with IBC Chapters 15 & 26 will be forwarded by them to you. 7/21/2006 Page 2 of2 Mark Woodruff 920-922-3110 W. J. Woodruff Roofing Contractors, Inc. POBox 763 Fond du Lac WI 54936-0763 www.woodruffroofing.com ws)QQIlJff@y.rQQ9Il,Jff[QQfiDgA~Qm 7/21/2006 Page 1 of 1 Noe, Brian From: Noe, Brian Sent: Thursday, July 20, 2006 9:58 AM To: 'Mark A. Woodruff' Subject: RE: Roofing permit for 830 Witzel Ave Oshkosh Thank you for the information, when we receive the additional information from the Owner, and have reviewed It we will process your permit application. No work is permitted to be done until a permit is issued. -----Original Message----- From: Mark A. Woodruff [mailto:woodruff@woodruffroofing.com] Sent: Thursday, July 20, 20069:05 AM To: bnoe@cLoshkosh.wLus Subject: Roofing permit for 830 Witzel Ave Oshkosh Brian: You asked for information concerning the reroofing work for the AT&T/SBC garage at 830 Witzel. The specification developed by the owner includes: 1- removing of the existing adhered EPDM roofing, roof insulation, and built-up roofing. 2- the new roof is a Johns Manville roof system SE6A consisting of a 1.5" polyiso ISO 3 insulation, a 1/2" fiberboard insulation mechanically attached with one fastener per two square feet to the plywood deck, then a fully adhered 60 mil reinforced EPDM membrane is fully adhered, at the existing gutter locations, new gutters are being installed, at the roof edge, the roof edge metal and a new metal fascia are being installed. No other modifications to the structure are specified. For FM & UL - ISO 3 is rated in Factory Mutual fire and wind-resistant systems for BUR, modified bitumen and single ply systems in specific constructions. It has been classified by UL as an approved roof insulation in many Class A roof constructions and Roof/Ceiling hourly fire-rated assemblies, and is classified by UL Canada. Since the roofing system specifications were designed by the owner, the information you requested for compliance with IBC Chapters 15 & 26 will be forwarded by them to you. Mark Woodruff 920-922-3110 W. J. Woodruff Roofing Contractors, Inc. POBox 763 Fond du Lac WI 54936-0763 WWW,WQQdl::\JtfrQQJiOg.,GQm WQQdLYtf@WQQ.drwfffQQfing.,GQIIJ 7/20/2006 7/21/2006 e Page 2 of2 Sent: Thursday, July 20, 2006 9:05 AM TO:PJJQE:;@Ci,Q$b!s.Q$Jl,WJ,-~$ Subject: Roofing permit for 830 Witzel Ave Oshkosh Brian: You asked for information concerning the reroofing work for the AT&T/SBC garage at 830 Witzel. The specification developed by the owner includes: 1- removing of the existing adhered EPDM roofing, roof insulation, and built-up roofing. 2- the new roof is a Johns Manville roof system SE6A consisting of a 1.5" polyiso ISO 3 insulation, a 1/2" fiberboard insulation mechanically attached with one fastener per two square feet to the plywood deck, then a fully adhered 60 mil reinforced EPDM membrane is fully adhered, at the existing gutter locations, new gutters are being installed, at the roof edge, the roof edge metal and a new metal fascia are being installed. No other modifications to the structure are specified. For FM & UL - ISO 3 is rated in Factory Mutual fire and wind-resistant systems for BUR, modified bitumen and single ply systems in specific constructions. It has been classified by UL as an approved roof insulation in many Class A roof constructions and Roof/Ceiling hourly fire-rated assemblies, and is classified by UL Canada. Since the roofing system specifications were designed by the owner, the information you requested for compliance with IBC Chapters 15 & 26 will be forwarded by them to you. Mark Woodruff 920-922-3110 W. J. Woodruff Roofing Contractors, Inc. POBox 763 Fond du Lac WI 54936-0763 www.woodruffroofing.com !N:QQQLWff@wQQQwffmQfiog,gPill information BUilllNG ENVUOPESOUJTiONS July 21, 2006 City of Oshkosh Permit Division Attn: Brian Noe Dear Mr. Noe, Subject: RE: Roofing permit for 830 Witzel Ave Oshkosh The re-roofing specification for the AT&T building at 830 Witzel A venue is from the American Institute of Architects (AlA) Masterspec@ program. The elements of the AlA master specification meets or exceeds the IBC codes minimum building standards. The roofing system specified follows the requirements of Chapter 15 Roof Assemblies and Rooftop Structures. The foam plastic insulation specified is polyisocyanurate (with a flame spread rating of less than 75) which meets the requirements of material and installation of Chapter 26. CWS Source Inc. (RCI #28816) has been hired by AT&T to monitor and inspect the work on the project to insure that the specification is followed during the re-roofing process. If you have any further questions or concerns, please do not hesitate to contact us. Thank you, Ann E. Hanna i I i I CWS SOURCE INC. Phone (262) 781-4329 (888) 883-6269 Fax (262) 781-4829 12600 Robin Lane, Brookfield, WI 53005 WWW.cwssource.com X~';J-~~'E--.-G~2Lb"T~~.,....J:?\;;f~B\PS"':1(6).... . 'O..F " ..... .~..... ...."....-.- .", ,,"'.,.-. ..,...--.... - . ,,-.... ~,,_. ......_--~~,,_..,~._--....-. . ." . .. """-... . ---~.~~ -'--""_'~~'_"_"_"'__._~___ ~M__~.~~_.,._,~,.._... .,...._. _.. :.~~--~T-......_~~~J6'TlI'.Jb__..____~~J!'V~..... .~~jr;&\t5~ ... ....fJ:ffG:-....E~).~~ K ~~ .'" _..\ .._~.~.._... . ..!\J..t,.;....._.... . .___..__.__... ...___._....._____.__..."............._.._... ....... ." .- ..,.,,--,-.....-.- '"...-.-.~-~...,...._-'--".,~~._---"..._"._'_._-"..~"._".~.._~~...."..._..._"~~~._..__._._'._~.AA_"M___'._"_.... .., '.~-~~.__.-lS!E~-~R'Q1:!E~b_._.~~"Tl:;~,...f'c~.J .... =..J)~(k,..~(..r~~~I-t:'.!;1:2W8.!YC:... . ... ..t:7.~--...._..f\;::;:{E_......-"'TI.?._.~E==._~Ak~<::::O. .. ...,.,..-..... ,~.......,.._.._. ,,-.".-.. ..._-....._,,_..,._.._-,,~~'...-. ...""~-.....,,._~........_.._.,.~~_..~.-...,---_.._.~._.-.---..'''' - ..~E'N(.............8Y.ST1.:-~_...~,-,vt:\ I:/NIA:T}W. SHOJ'NW~~_:....CQ.t"}.EktJj>'\).'~ tv.rTJ:f~~B~_ =-._..CH1!f:.t!I~-_1S'.A';AID_n .. 26 o ,"""0 ,~-,-,__" ,-,.' ." -.. ,_ ....... ,,' ~"'_"""'__'_""'_~_'_"_."_"""'" _""~"o,., '''''''.' '""U_~"'.'~"_" .'_"'_.'" .., City of Oshkosh Inspection Services Division POBox 1130 Oshkosh, WI 54903-1130 Phone: (920) 236-5050 Fax: (920) 236-5084 (t) OfHKOfH ON THE' WATER Roofing & Siding Permit Application . Application(s) and fee(s) can be brought to City Hall, Room 205 or mailed to Inspection Services, PO Box 1128, Oshkosh WI 54903-1128. Commencing work without permit(s) will result in fees being doubled or $100.00 plus the normal permit fee, which ever is greater. OR If vou are a contractor participating in the Permit fee Account Svstem and have adequate funds. check here if vou want this processed through vour account n JOB ADDRESS 830 witzel Ave AT&T OWNER CONTRACTOR W J Woodruff Roofing Contractors, Inc. I am the: DOwner OR 81 Contractor USE CATEGORY o Single Family . 0 Duplex o Multi-Family o Rental 0lI Commercial o Industrial Work being done: ROOFING ~ Tear off and replace existing roofing on 0 house, 0lI garage o Replace wood decking o Add 1 layer of roofmg to the existing layer( s) on 0 house, 0 garage This work is being done due to 0 Hail Damage KI Other a q e SIDING ..... o Install siding on 0 house, 0 garage o Replacing vinyl with vinyl o Replacing steel or aluminum with vinyl (circle steel or aluminum) o Replacing with This work is being done due to 0 Hail Damage 0 Other When siding is done, one of the boxes below must be checked: I) 0 Electric - Existing Electric Meter, receptacle, lighting and Electric Service entrance alterations/modifications are being performed by (Name of Licensed Electric Contractor) AND C Electric Installation Verification form is attached OR C Separate Elect Permit will be requested. 2) 0 Electric - Not Applicable because; 0 J Blocks previously installed. 0 No outside lights. [] Other o Install new or:gJ Replace gutters o Install new or Xl Replace downspouts Other related work being done: (please note) Value ofthe job $ 72,800.00 (include fair market price for labor even if you are not paying for labor) 03/02