Job Address 820 WITZEL AVE
CITY OF OSHKOSH No 120733
BUILDING PERMIT - APPLICATION AND RECORD
Owner WIS TELEPHONE CO Create Date 07/25/2006
Designer
CWS Source Inc
Contractor W J WOODRUFF ROOFING CONTRACTORS It
Category
210 - Addition Industrial
Plan
Type
. Building
o Sign
o Canopy
o Fence
o Raze
Zoning
Class of Const: VB
Size
Unfinished/Basement
Sq.Ft.
Rooms
Height
Ft.
D Projection I
Finished/Living
Sq.Ft.
Bedrooms
Stories
Canopies
Garage
Sq.Ft.
Baths
Signs
Foundation . Poured Concrete 0 Floating Slab
o Concrete Block 0 Post
o Pier 0 Other
o Treated Wood
Occupancy Permit Not Required
Flood Plain No
Height Permit Not Required
Park Dedication
Not Required
# Dwelling Units
o
# Structures
o
UselNature
of Work
IND/ Tear-off roofing material down to existing structural wood deck consisting of tongue-and-groove plywood deck that complies with IBC
section 2603.4.1.5, and install 1.5" of polyisocyanurate insulation followed by .5" woodfiber roof insulation, new EPDM rubber membrane,
and flashing per manufactures specifications.
HV AC Contractor
Plumbing Contractor
Electric Contractor
$72,800.00 Plan Approval
$0.00 Permit Fee Paid
$317.00 Park Dedication
Fees: Valuation
$0.00
Issued By:
Date 07/25/2006
Final/O.P. 00/00/0000
D Permit Voided I
Parcel Id # 0609670000
In the performance of this work I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement
holder(s) and to secure any necessary approvals before starting such activity.
Signature
Date
Address PO BOX 763
Agent/Owner
FOND DU LAC
WI 54936 - 0763 Telephone Number 920-922-3110
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (Le. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
'b':JQ
821
.
.
820
.
.
<b\:'
.
804
815
xc:
CWS SOURCE, INC.
12600 ROBIN LN.
SUITE 100
BROOKFIELD, WI 53005
DATE:
07/24/06
NO.:
01
CONSTRUCTION BULLETIN
PROJECT: RE-ROOFING
830 WITZEL AVE. OSHKOSH, WI
PROJECT NO.:
TO: DAN BUCHBURGER
MARK WOODRUFF
BRIAN NOE
RE: mc COMPLIANCE
GENERAL:
This bulletin is issued to define the scope of revision in drawings and/or specifications for a contemplated
change. The work required by these revisions shall be in accordance with the general requirements of the
original contract documents. This bulletin is not a change order and work shall not be started without
written authorization to proceed by Owner. The Contractor is requested to submit an itemized proposal
for the revised work and identify the effect this change will have on construction cost and schedule if any.
DESCRIPTION OF REVISION:
The scope has been changed to indicate the compliance of the existing plywood deck with IBC
2603.4.1.5 as noted in section B.2.e :
B. SCOPE OF WORK
1. Furnish and install specified roofing and related components to AT&T totaling approximately
12,444 square feet.
2. Work Includes: BASE BID - FULLY ADHERED, REINFORCED, EPDM RUBBER
a. Roof areas 2 & 3
b. Removal and replacement of designated roofing and insulation.
1) Remove roofing and insulation down to structural wood deck, flashings to substrate.
Note: Owner requests that Contractor take all precautions to reuse the existing
gutter edge system, if possible.
2) Electrical heat tape system will be disconnected by others. Roofing contractor to
remove heat tape system and reserve for re-installation on new roof system (See note
below).
c. Removal of Owner designated equipment and equipment supports.
d. Localized substrate repair as required.
e. Installation of the following over the existing, %" tongue and groove plywood deck (in
compliance with IBC 2603.4.1.5):
I) I-Layer of 1.5" Polyisocyanurate roof insulation.
2) I-Layer of .5" woodfiber roof insulation.
3) Crickets installed in designated areas
4) Rework existing drains.
5) Install new, reinforced EPDM rubber membrane, flashings and accessories per
manufacturer's specifications.
6) Specified metal flashings and accessories.
-;ij
7) Clean, prime and aluminize all existing sheet metal roof projections.
8) Install compatible walkway protection pads around all rooftop vent units.
ATTACHMENTS: NONE
ISSUED BY: Andy Angermeier
CWS Source, Inc.
Page 1 of2
Noe, Brian
From: Noe, Brian
Sent: Friday, July 21,20063:25 PM
To: 'Mark A. Woodruff'
Subject: RE: Roofing permit for 830 Witzel Ave Oshkosh
NO - we can not issue a permit yet The document you sent does not address how you are complying with the thermal barrier
requirements, and does nothing to tell us what the roof assembly is going to be.
I contacted Ann Hanna, and discussed these issues with her, and she will be looking into this and providing me with additional
information. Until I receive that information and have reviewed it, we are not able to issue a permit, and no work is permitted to
begin.
If you have any questions feel free to contact me.
Brian Noe
City of Oshkosh
Building Systems Consultant
(920) 236-5051
-----Original Message-----
From: Mark A. Woodruff [mailto:woodruff@woodruffroofing.com]
Sent: Friday, July 21, 2006 3:08 PM
To: Noe, Brian
Cc: Angermeier, Andy; Hanna, Ann E.
Subject: Re: Roofing permit for 830 Witzel Ave Oshkosh
Attached is the additional information you requested.
Are we okay to start the project on Monday 7/24/06?
Mark Woodruff 920-922-3110
W. J. Woodruff Roofing Contractors, Inc.
POBox 763
Fond du Lac WI 54936-0763
W..wW~'\"LQQgruffr:QQflng,~Qm
wood ruff@woodruffroofing.com
----- Original Message -----
From :NQ~LJ~Ii<?1l
To: 'Mark A. Woodruff'
Sent: Thursday, July 20, 2006 9:58 AM
Subject: RE: Roofing permit for 830 Witzel Ave Oshkosh
Thank you for the information, when we receive the additional information from the Owner, and have reviewed it we will
process your permit application. No work is permitted to be done until a permit is issued.
-----Original Message-----
From: Mark A. Woodruff [mailto:woodruff@woodruffroofing.com]
, 7/21/2006
Page 1 of2
Noe, Brian
From: Mark A. Woodruff [woodruff@woodruffroofing.com]
Sent: Friday, July 21, 2006 3:08 PM
To: Noe, Brian
Cc: Angermeier, Andy; Hanna, Ann E.
Subject: Re: Roofing permit for 830 Witzel Ave Oshkosh
Attached is the additional information you requested.
Are we okay to start the project on Monday 7/24/06?
Mark Woodruff 920-922-3110
W. J. Woodruff Roofing Contractors, Inc.
POBox 763
Fond du Lac WI 54936-0763
www.woodruffroofing.com
WQQQIlJIT@WQQQIYffCQolJOg,G9-fTI.
----- Original Message -----
From: Noe, Brian
To: ~MgJ!s.A,YYooJ;!rlJff
Sent: Thursday, July 20,20069:58 AM
Subject: RE: Roofing permit for 830 Witzel Ave Oshkosh
Thank you for the information, when we receive the additional information from the Owner, and have reviewed it we wi!! process
your permit application. No work is permitted to be done until a permit is issued.
-----Original Message-----
From: Mark A. Woodruff [mailto:woodruff@woodruffroofing.com]
Sent: Thursday, July 20, 2006 9:05 AM
To:bnQ~@g,Q$hko$h,\,I\{LU$
Subject: Roofing permit for 830 Witzel Ave Oshkosh
Brian:
You asked for information concerning the reroofing work for the AT&T/SBC garage at 830 Witzel.
The specification developed by the owner includes:
1- removing of the existing adhered EPDM roofing, roof insulation, and built-up roofing.
2- the new roof is a Johns Manville roof system SE6A consisting of a 1.5" polyiso ISO 3 insulation, a 1/2" fiberboard
insulation mechanically attached with one fastener per two square feet to the plywood deck, then a fully adhered 60 mil
reinforced EPDM membrane is fully adhered, at the existing gutter locations, new gutters are being installed, at the roof
edge, the roof edge metal and a new metal fascia are being installed. No other modifications to the structure are specified.
For FM & UL - ISO 3 is rated in Factory Mutual fire and wind-resistant systems for BUR, modified bitumen and single ply
systems in specific constructions. It has been classified by UL as an approved roof insulation in many Class A roof
constructions and Roof/Ceiling hourly fire-rated assemblies, and is classified by UL Canada.
Since the roofing system specifications were designed by the owner, the information you requested for compliance with IBC
Chapters 15 & 26 will be forwarded by them to you.
7/21/2006
Page 2 of2
Mark Woodruff 920-922-3110
W. J. Woodruff Roofing Contractors, Inc.
POBox 763
Fond du Lac WI 54936-0763
www.woodruffroofing.com
ws)QQIlJff@y.rQQ9Il,Jff[QQfiDgA~Qm
7/21/2006
Page 1 of 1
Noe, Brian
From: Noe, Brian
Sent: Thursday, July 20, 2006 9:58 AM
To: 'Mark A. Woodruff'
Subject: RE: Roofing permit for 830 Witzel Ave Oshkosh
Thank you for the information, when we receive the additional information from the Owner, and have reviewed It we will process your
permit application. No work is permitted to be done until a permit is issued.
-----Original Message-----
From: Mark A. Woodruff [mailto:woodruff@woodruffroofing.com]
Sent: Thursday, July 20, 20069:05 AM
To: bnoe@cLoshkosh.wLus
Subject: Roofing permit for 830 Witzel Ave Oshkosh
Brian:
You asked for information concerning the reroofing work for the AT&T/SBC garage at 830 Witzel.
The specification developed by the owner includes:
1- removing of the existing adhered EPDM roofing, roof insulation, and built-up roofing.
2- the new roof is a Johns Manville roof system SE6A consisting of a 1.5" polyiso ISO 3 insulation, a 1/2" fiberboard insulation
mechanically attached with one fastener per two square feet to the plywood deck, then a fully adhered 60 mil reinforced
EPDM membrane is fully adhered, at the existing gutter locations, new gutters are being installed, at the roof edge, the roof
edge metal and a new metal fascia are being installed. No other modifications to the structure are specified.
For FM & UL - ISO 3 is rated in Factory Mutual fire and wind-resistant systems for BUR, modified bitumen and single ply
systems in specific constructions. It has been classified by UL as an approved roof insulation in many Class A roof
constructions and Roof/Ceiling hourly fire-rated assemblies, and is classified by UL Canada.
Since the roofing system specifications were designed by the owner, the information you requested for compliance with IBC
Chapters 15 & 26 will be forwarded by them to you.
Mark Woodruff 920-922-3110
W. J. Woodruff Roofing Contractors, Inc.
POBox 763
Fond du Lac WI 54936-0763
WWW,WQQdl::\JtfrQQJiOg.,GQm
WQQdLYtf@WQQ.drwfffQQfing.,GQIIJ
7/20/2006
7/21/2006
e
Page 2 of2
Sent: Thursday, July 20, 2006 9:05 AM
TO:PJJQE:;@Ci,Q$b!s.Q$Jl,WJ,-~$
Subject: Roofing permit for 830 Witzel Ave Oshkosh
Brian:
You asked for information concerning the reroofing work for the AT&T/SBC garage at 830 Witzel.
The specification developed by the owner includes:
1- removing of the existing adhered EPDM roofing, roof insulation, and built-up roofing.
2- the new roof is a Johns Manville roof system SE6A consisting of a 1.5" polyiso ISO 3 insulation, a 1/2" fiberboard
insulation mechanically attached with one fastener per two square feet to the plywood deck, then a fully adhered 60
mil reinforced EPDM membrane is fully adhered, at the existing gutter locations, new gutters are being installed, at
the roof edge, the roof edge metal and a new metal fascia are being installed. No other modifications to the structure
are specified.
For FM & UL - ISO 3 is rated in Factory Mutual fire and wind-resistant systems for BUR, modified bitumen and single
ply systems in specific constructions. It has been classified by UL as an approved roof insulation in many Class A roof
constructions and Roof/Ceiling hourly fire-rated assemblies, and is classified by UL Canada.
Since the roofing system specifications were designed by the owner, the information you requested for compliance
with IBC Chapters 15 & 26 will be forwarded by them to you.
Mark Woodruff 920-922-3110
W. J. Woodruff Roofing Contractors, Inc.
POBox 763
Fond du Lac WI 54936-0763
www.woodruffroofing.com
!N:QQQLWff@wQQQwffmQfiog,gPill
information
BUilllNG ENVUOPESOUJTiONS
July 21, 2006
City of Oshkosh
Permit Division
Attn: Brian Noe
Dear Mr. Noe,
Subject: RE: Roofing permit for 830 Witzel Ave Oshkosh
The re-roofing specification for the AT&T building at 830 Witzel A venue is from the
American Institute of Architects (AlA) Masterspec@ program. The elements of the AlA
master specification meets or exceeds the IBC codes minimum building standards. The
roofing system specified follows the requirements of Chapter 15 Roof Assemblies and
Rooftop Structures.
The foam plastic insulation specified is polyisocyanurate (with a flame spread rating of
less than 75) which meets the requirements of material and installation of Chapter 26.
CWS Source Inc. (RCI #28816) has been hired by AT&T to monitor and inspect the
work on the project to insure that the specification is followed during the re-roofing
process.
If you have any further questions or concerns, please do not hesitate to contact us.
Thank you,
Ann E. Hanna
i I
i I
CWS SOURCE INC. Phone (262) 781-4329 (888) 883-6269 Fax (262) 781-4829 12600 Robin Lane, Brookfield, WI 53005
WWW.cwssource.com
X~';J-~~'E--.-G~2Lb"T~~.,....J:?\;;f~B\PS"':1(6).... .
'O..F
" ..... .~..... ...."....-.- .", ,,"'.,.-. ..,...--.... - . ,,-.... ~,,_. ......_--~~,,_..,~._--....-. . ." . .. """-... . ---~.~~ -'--""_'~~'_"_"_"'__._~___ ~M__~.~~_.,._,~,.._... .,...._. _..
:.~~--~T-......_~~~J6'TlI'.Jb__..____~~J!'V~..... .~~jr;&\t5~ ... ....fJ:ffG:-....E~).~~
K ~~ .'"
_..\ .._~.~.._... . ..!\J..t,.;....._.... . .___..__.__... ...___._....._____.__..."............._.._... ....... ."
.- ..,.,,--,-.....-.- '"...-.-.~-~...,...._-'--".,~~._---"..._"._'_._-"..~"._".~.._~~...."..._..._"~~~._..__._._'._~.AA_"M___'._"_.... ..,
'.~-~~.__.-lS!E~-~R'Q1:!E~b_._.~~"Tl:;~,...f'c~.J .... =..J)~(k,..~(..r~~~I-t:'.!;1:2W8.!YC:...
. ... ..t:7.~--...._..f\;::;:{E_......-"'TI.?._.~E==._~Ak~<::::O. ..
...,.,..-..... ,~.......,.._.._. ,,-.".-.. ..._-....._,,_..,._.._-,,~~'...-. ...""~-.....,,._~........_.._.,.~~_..~.-...,---_.._.~._.-.---..''''
- ..~E'N(.............8Y.ST1.:-~_...~,-,vt:\ I:/NIA:T}W.
SHOJ'NW~~_:....CQ.t"}.EktJj>'\).'~
tv.rTJ:f~~B~_ =-._..CH1!f:.t!I~-_1S'.A';AID_n .. 26
o ,"""0 ,~-,-,__" ,-,.' ." -.. ,_ ....... ,,' ~"'_"""'__'_""'_~_'_"_."_"""'" _""~"o,., '''''''.' '""U_~"'.'~"_" .'_"'_.'" ..,
City of Oshkosh
Inspection Services Division
POBox 1130
Oshkosh, WI 54903-1130
Phone: (920) 236-5050
Fax: (920) 236-5084
(t)
OfHKOfH
ON THE' WATER
Roofing & Siding Permit Application
. Application(s) and fee(s) can be brought to City Hall, Room 205 or mailed to Inspection Services, PO Box 1128,
Oshkosh WI 54903-1128. Commencing work without permit(s) will result in fees being doubled or $100.00 plus the
normal permit fee, which ever is greater.
OR
If vou are a contractor participating in the Permit fee Account Svstem and have adequate funds. check here
if vou want this processed through vour account n
JOB ADDRESS 830 witzel Ave
AT&T
OWNER
CONTRACTOR
W J Woodruff Roofing Contractors, Inc.
I am the:
DOwner
OR
81 Contractor
USE CATEGORY
o Single Family . 0 Duplex
o Multi-Family
o Rental
0lI Commercial
o Industrial
Work being done:
ROOFING
~ Tear off and replace existing roofing on 0 house, 0lI garage
o Replace wood decking
o Add 1 layer of roofmg to the existing layer( s) on 0 house, 0 garage
This work is being done due to 0 Hail Damage KI Other a q e
SIDING
.....
o Install siding on 0 house, 0 garage
o Replacing vinyl with vinyl
o Replacing steel or aluminum with vinyl (circle steel or aluminum)
o Replacing with
This work is being done due to 0 Hail Damage 0 Other
When siding is done, one of the boxes below must be checked:
I) 0 Electric - Existing Electric Meter, receptacle, lighting and Electric Service entrance alterations/modifications are being performed
by
(Name of Licensed Electric Contractor)
AND C Electric Installation Verification form is attached OR
C Separate Elect Permit will be requested.
2) 0 Electric - Not Applicable because; 0 J Blocks previously installed. 0 No outside lights. [] Other
o Install new or:gJ Replace gutters
o Install new or Xl Replace downspouts
Other related work being done: (please note)
Value ofthe job $
72,800.00
(include fair market price for labor even if you are not paying for labor)
03/02