Loading...
HomeMy WebLinkAbout0120720-Electric e OSHKOSH ON THE WATER Job Address 2900 ATLAS AVE Contractor SOLAR ELECTRIC SERVICES INC CITY OF OSHKOSH No 120720 ELECTRIC PERMIT - APPLICATION AND RECORD Owner CHAMCO Create Date 07/24/2006 Category 652 - Industrial-New Building Wiring Plan o N/A Type 0 Overhead . Underground Service . New 0 Change 0 Temp 277/480 Circuits Luminaires Volts Receptacles Amps 1600 Switches Appliances L Use/Nature of =INew 79,356 sf factory/warehouse. Phase 3 Work , I 1- Fees: Valuation $573.00 $120,000.00 Plan Approval $0.00 Permit Fee Paid Issued By: Date 07/24/2006 o Permit Voided I Parcel Id # In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Agent/Owner Address 3443 BROOKS RD OSHKOSH WI 54904 - 0 Telephone Number 231-3990 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (I.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. Electric Permit Work Card ,r. Jon,Addres~ 2900 ATLAS AVE Permit Number 120720 Create Date 7/24/2006 Owner CHAMCO Contractor SOLAR ELECTRIC SERVICES INC Category 652 - Industrial-New Building Wiring Service :. New o ChangeO Temp ON/A I Type 0 Overhead . Underground ON/A I Volts 277/480 Circuits Luminaires Amps 1600 Switches Receptacles Fee $573.00 D Value $120,000.00 Appliances Use/Nature New 79,356 sf factory/warehouse. Phase 3 of Work Inspections: Type Rough In Inspector Kevin Benner approved Date 08/14/2006 Request line / Office walls only. Datemme requested: 08/14/2006 12:01 PM Access: Notice Type: Phone Number: none given Ready Datemme: 08/14/200612:01 PM Requested by: SOLAR ELECTRIC SERVICES INC o Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid Date 08/17/2006 Type Re Service Inspector Kevin Benner approved wIeand. Faxed to WPS / Approved to energize MCB AIC is 65K Per Tom (electrician on site) GFP test results are approx. : 200A @ .3 sec. Cutler Hammer paperwork to will be forwarded by Solar Electric per Jim. (; 'F ~? -r -e-b t:- ~S.~\-\:.. S ~~--e..-C) Datemme requested: 08/17/20~ 08:27 AM Access: Notice Type: Phone Number: 410-5174 Jim Ready Datemme: 08f17f2006 08:27 AM Requested by: o Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid SOLAR ELECTRIC SERVICES INC Jim -- . @...;;..;.A?,:\6:..2066..6:W:fi1......WEstli.DiStRi6UHON.j ~e,iiih'''''''''''''''' ........ '" 'No} 155 ..... P. .1....'.................. _'" . r}/Zit-'. . I "~T.N Electrical -- Servloes & Systems L ow Voltage Breaker CUSTOMER: I Leece Stllll1 CH JOB NUMBER: ~:22tl JOEl lOCATION: I OlJb1mab. 'WI DATE TESTED: 08;'~ 7/;/OOfi FIELD DATA EQUIPt\ilENT LOCATION: I Main Breaker EQUIPMENT 10: I Main SREAKE;R INFORhI^TlON TRIP UNIT INFORMATION MANUFACTUREFI: Eaten I F.1e Irl:dc 111 MANUFACTUREA~ Eaton f Electrl.:e1 MODEL #. RD61l5TlllSW TrllP UNIT 1i'PE: Dil:litt'1l!1 310 SERIAl #: n:!:: CURVE #: UiO FRAME SIZE: 1600A RATING PLUG: 1600A INTERRUPTING AATING: 6~KA SENSOR TAP RANGES: ~ 600A RATED CLOSE celt. VlJI..TAt:lE: NA SENSOR TAP USED: 1600A RATEO CHARSE VOLTAGE: NA SETTINGS AS FOUND AS LEFT RATED TRIP COIL VOLTAGE: NA LONG DElAY PICKUP: rmr! Plxed INSTRUCTION BOOKl.ET #; LONG DELAV TIME: Fixec! F~~d INCOMMADDAESS \ BAUD RATE: NA SHOAT DElAY PICKUP: I5X 5X LIMITER INFORMATllJN SHORT DELAY TIME: ,Sill ,,55 MANUFACTURER: NA INSTANTANEOUS; NA NA CAT #: GRDUND FAU1.T PICKUP: 2DOA 200A RATED AMPS: GROUND FAULT TIME: .'sS jS INSPECTION DATA DRAW' OUT IAACKING MECHANISM: ARC CHUTES: PHYSIi::ALIMECHANICAL CONDITlON; MAIN CONTACT CONDITICN: CELL/FRAME CONDITION; - ARCING CONTACT cONDITIDN: MECHA~ICAL INTERLOCKS: OPERATING ~ECHANISM: PAIMARYISECONDAR"r' DISCONNECTS: MANUAL OPERATION: G~OUND CONNECTION: STATU5INDICATCR5: INSULA TORS/BARRI!::AS: LIMITERS: Legsnd: "'-ACCEPTABLE C-CORRECTED N-NEEDS REPAIR NA.NOT APPUCABlE NS-NOT IN SCOPE ELECTRICAL TEST DATA TI'::5T PROCEDURE: Prim\'UV lnir:r;1UIc BLOWN UMITER INDICATORS: TIMING TESTS SETTING TEST % CLlRRENT MIN MAX PHASE ^ PHASE B I PHA.SE C IT PICXUP: I I LT DELAY: :roO ST P1CKUP~ ST DELAY: 1.sD INST PICKUP: [iF PICKUP: . :.lOOA IBM 22[JA 200A 200A. 2COA GFDEIAY; ..sSeI':, BO .58 .5S .~iS TRIP UNIT ADJUSTMENT AEQUIAED~ I IN~UTFlAL SENSOR pOLARITY: 8REAKER coNTACT RESISTANCE rMICRO..oHMS) TPHASEA: I IPHASE 6: I pHASEC: I l.IMITER RESISTANCE I IMIl..LI-OHMS~ I PHASE A: I IPHASE B: I PHASE c: I INSULATION RESISTANCE: C1.DSEO \PH-END) O~N (UNE-GND] OPEN lLOAD.GNDJ @ VOl. TS Or.: [MEGOHMS) A . 8 C A B C A 8 .C CONTRaL WIRING J/lJSULATION @5oo V DC (MEGOHMS):T IllECTRICAL. OPERATION: I CDMMENTS .. L ~& ~aket WIlS tested.f'cr t1ouo~ f'flull. MI./! f'm,ml!1 in srJ.isf'lletory condition for 5SmC! . TEST EQUIP ID/CAL OA1E:T IDATAfI~: I 1.0!8 m13fl.gl2(]O~ TESTED B'r':1 P!te Chellmll ITf:;MPLATE REV; I .5.0 as of8ffiflIJD1 ..... Received Time Aug. 21. 8:24AM '-.1 Electric Permit Work Card Job Address 2900 ATLAS AVE Permit Number 120720 Create Date 7/24/2006 Owner CHAM CO Contractor SOLAR ELECTRIC SERVICES INC Category 652 - Industrial-New Building Wiring Service . New o ChangeO Temp ON/A I Type 0 Overhead . Underground ON/A I Volts 277/480 Circuits Luminaires Amps 1600 Switches Receptacles Fee $573.00 0 Value $120,000.00 Appliances Use/Nature New 79,356 sf factory/warehouse. Phase 3 of Work Inspections: Type Rough In Inspector Kevin Benner approved Date 08/14/2006 Request line / Office walls only. DatelTime requested: 08/14/2006 12:01 PM Access: Notice Type: Phone Number: none given Ready DatelTime: 08l~i/2006 12:01 PM Requested by: SOLAR ELECTRIC SERVICES INC o Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid Date 08117/2006 Type !3~~~!ce Inspector Kevin Benner approved wIeand. Faxed to WPS / Approved to energize MCB AIC is 65K Per Tom (electrician on site) GFP test results are approx. : 200A @ .3 sec. Cutler Hammer paperwork to will be forwarded by Solar Electric per Jim. DatelTime requested: Q~~1!!~og?__ 08:27 AM Access: Notice Type: Phone Number: 410-5174 Jim Ready DatelTime: 08/17/2Q.0~ 08:27 AM Requested by: SOLAR ELECTRIC SERVICES INC Jim o Reinspect Fee 0 Fee Wavied D Reinspect Fee Paid