HomeMy WebLinkAbout0120573-Building (roof)
..
OSHKOSH
ON THE WATER
.:lob Address 1401 W 5TH AVE
CITY OF OSHKOSH No 120573
BUILDING PERMIT - APPLICATION AND RECORD
Owner OSH AREA SCHL DIST FRANKLIN Create Date 07/18/2006
Designer
Contractor
LAKEWOOD ROOFING
Category
229 - Alteration Schools & other Educational
Plan
Type
. Building
o Sign
o Canopy
o Fence
o Raze
Zoning
Class of Const:
Size
Unfinished/Basement
Sq.Ft.
Sq.Ft.
Sq.Ft.
Rooms
Height
Ft.
o Projection I
Finished/Living
Bedrooms
Stories
Canopies
Garage
Baths
Signs
Foundation
. Poured Concrete 0 Floating Slab
o Concrete Block 0 Post
o Pier
o Treated Wood
o Other
Occupancy Permit Not Required
Flood Plain No
Height Permit Not Required
Park Dedication
Not Required
# Dwelling Units
o
# Structures
o
Use/Nature ISchool / Tear-off roofing and install new roofing system as per plans, in accordance with Roof construction detail No 120 on roofs A, A-1,
of Work 'f-2, C,. D. This permit also includes Roof E, in which work is not permitted to begin until construction details, have been approved by this
office.
HV AC Contractor
Plumbing Contractor
Electric Contractor
48,536.30 Plan Approval
$0.00 Permit Fee Paid
$535.00 Park Dedication
$0.00
Fees: Valuation
Issued By:
Date 07/18/2006
Final/O.P. 00/00/0000
o Permit Voided I
Parcel Id # 0608530000
In the performance of this work I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement
holder(s) and to se re any sary appro Is before starting suchactivity.
Signature
Date ;Z~R,....d&
Address P.O. BOX 15
Agent/Owner
~
WINNEBAGO
WI 54985 - 0015 Telephone Number 235-1955
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (I.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
x%"irF'
1'0~}';
I
I~
I
I
14.
15.
16.
17.
18.
SCOPE OF WORK - REPLACEMENT ROOF SECTIONS:
Franklin Elementary School
Replacement Roof Sections:
Roof A I Roof A-II Roof A-21 Roof C I Roof D I Roof E
1.
Tear-off existing multi ply roof systems, insulation, flashings and sheet metal down to the metal deck. Ensure deck surfuce
is clean and free of debris. Roof Section E - Deck Yz Wood Yz Concrete.
Inspect decking for any defects. Replace defective decking in kind. (submit a sq. foot price for like decking)
Install wood blocking and cants as specified around all units and at the perimeters (Per FM 190)
Rework existing drains. Mount drains on deck and create 4' x 4' sump using factory-tapered insulation.
Raise all units 8" above the finished roof surface.
Install new treated wood curbslblocking around and rooftop units and perimeters.
Mechanically fusten-using appropriate fusteners and cover plates per FM 190 -1I8" per fuot taper POlyisocyanurate
Insulation Minimum Start I V:." "FLAT STOCK" - "Follow Attached Specifications".
a. On Roof Section E (W ood Side) - Install Red Rosin Paper and 28 Ib Base Sheet with nail fusteners. .
You will then install the Below insulation with appropriate mechanical fusteners _ per FM 190.
b. On Roof Section E (Concrete Side) - Install the below insulation with Type 4 Asphalt at 25lbs per square.
c. Install new wood blocking in (a solvent free, moisture curing, very low odor, asphaltic-urethane, insulation adhesive
with high elastomeric properties)..
Install fuctory-tapered crickets/saddles (polyisocyanurate insulation) between drains, to drains, comers and on the high side
of units. The crickets and saddles will be at least twice the height of the tapered insulation. NO PONDING WATER
ALLOWED.INSURE THAT THE CRICKETS YOU INSTALL ARE SUFFICIENT TO DIVERT THE WATER TO THE
DRAINS.
Install top layer ofV:." High Density Woodfiber Board Insulation-Six Sided Asphalt Coated (4'x 4' Boards) set in Type (4)
Four Asphalt at the rate of#25 lbs per square - as specified.
Replace all defective roof drains with new cast iron drains. (This will be done by others-contractor to notify School)
Install new two (3) ply (high strength, polyester/fiberglass/polyester trilaminate reinforced asphalt coated ply sheets) in
cold processed application built-up roof system using (using an asbestos free, cold process, fibrated asphalt adhesive for
built up roofsysterns) at the rate of2.5 galIsq/ply. Along end laps, increase coverage to 2 _ V:. to 3 gal/sq.
All new flashings shall be (a elastomeric membrane made ofEPDM and SBR elastomers reinforced with a polyester
woven scrim). Set this elastomeric membrane in a (asbestos free, elastomeric adhesive) at 1 gaI/20 sq. ft. apply to both
surfaces.
Flashings should extend 6" onto roof from base cant; overlap vertical end laps a minimum of4".
a. Apply (elastomeric adhesive-per specifications) in a uniform continuous coverage and leave exposed for 15
minutes minimum (dependent upon weather).
b. Adhere (EPDM-SBR Elastomeric Reinforced Sheet in Elastomeric Adhesive) apply consistent pressure for a
unifurm adhesion and fully conforming to all angle changes without voids.
c. Secure top edge of sheeting by using the existing reglet joint and install a turn bar in 2 sided roofing tape and
counter flashing secured 8" O.C. caulk top ofCounterflashing (using a one-part, low modulus, moisture curing,
modified polyurethane sealant). If there is no regletjoint you must cut this in ifnot a brick wall
install turn bar -Two Sided RoofingTape and counter flashings. .
d. Strip in base flashing and vertical flashing laps using a three-course application of re-enforced fiberglass mesh
in (elastomeric adhesive-per specifications) and followed by (a single-component, weather resistant, asbestos
free durable roof elastomeric, suitable for use over both asphalt and tar roof membranes).
e. Coat flashings with (a refiective, asbestos free, aluminum coating for built-up roofs and flashings) two coat
Application at I-gal per 130 sq. ft. High ReflectiveAluminum Coating -per spec.
All new metal shall match existing with a kynar finish 24 Gauge. Per Specifications
All electrical disconnect and re-connect shall be by the Oshkosh School District.
Prior to application of surfuce treatment system, Contractor shall inspect the roof with the Owner, Full-Time Jobsite
Inspector and Roofing Foreman. All defects to be corrected.
Over entire roof surface spray apply uniform and continuous flood coat of solvent-free, cold process adhesive
Coverage rate: Five (5) gallons per one hundred (100) sq.ft.
Immediately broadcast a minimum of 400 lbs 1100 sq.ft of new, clean roofing gravel per one hundred (100) sq. ft. Provide
additional aggregate surfucing to provide a neat, uniform appearance and to cover all flood coat mater.ial completely.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
'1"
2005 ROOFING MATERIALS AND SYSTEMS DIRECTORY
572
ROOF DECK CONSTRUCTIONS (TGKX)
"
formed plated steel washer and a separate neoprene sealing washer.
Length to be 3/4 in. min when using 3 in. thick insulation and I in. min
for insulation over 3 in. Pilot holes to be 5/32 in. diam.
For panel to panel connections to be No. 12-14 by 1 in. self-drilling,
self-tapping, hex-head plated steel screws with a separate 1/2 in. O,D.
formed plated steel washer and a separate neoprene sealing washer.
Spacing for alternate fasteners to be the same.
4. Side lap Support Channel- Used under side lap of plastic skylight
and steel panels. Channel to be No. 20 MSG min gauge steel approx 11
ft-O in. in length. Channel configuration to be similar in shape to the
major rib of the "Multi-Rib" steel panel.
5. Batten Strip - Used over side lap of Building Unit No. 26 MSG min
gauge coated steel of the same configuration as the panel major rib.
6. Purlin - No. 16 MSG min gauge steel (min yield strength 50,000 psi).
7. Insulation - (optional) - Any compressible blanket insulation 4 in.
max thickness before compressions.
8. Lateral Bracing - Not shown, as required.
Refer to General Information, Roof Deck Construction, (Roofing Materials
and Systems Directory) for items not evaluated.
*Bearing the UL Classification Mark
Construction No. 119
Wind Uplift, Steel Panels - Class 90
Fire Not Investigated
1. Metal Roof Deck Panels' - No. 26 MSG min gauge coated steel. Pan-
els continuous over two or more spans. End laps to occur over purlins
with panels overlapped 4 in. with lap centered over purlin upper
flange. A bead of sealing compound may be used at panel end and side
laps.
MESCO METAL BUILDINGS -"Multi-Rib"
NCI BUILDING SYSTEMS L P -"Multi-Rib"
2. Panel Fasteners - For panel to purlin connections to be No. 12-14,
self-drilling, self-tapping, hex-head plated steel, stand-off screws with a
separate 5/8 in. O.D. formed steel washer and a separate neoprene
sealing washer. Length to be 7/8 in. longer than nominal thickness of
insulation.
Spacing to be JO in. O.C. with a fastener located 2-1/4 in. from the center
line on one side of each major rib. Spacing at end lap to be in a 4-1/2,
5-1/2, 4-1/2, 5-1/2 in. Pattern located 2-1/4 in. from the center line on
both sides of each major rib.
For panel to panel connections to be No. 14 by 3/4 in. self-tapping,
hex-head plated steel screws with a separate formed coated steel washer
and a separate neoprene sealing washer. Spacing to be one at the purlins
and one located between purlins. As an alternate fastener - for panel to
panel connections to be No. 12-14 by 1 in. self-drilling, self-tapping,
hex-head, plated steel screws with a separate 1/2 in. OD formed plated
steel washer and a separate neoprene sealing washer. Spacing to be the
same.
3. Insulation' - Rigid type. Supplied in 4 ft wide sheets; min thickness 1
in., max thickness 2 in. Butt joints to occur over purlins. Top surface of
all joints to be continuously sealed with a 2 in. wide vapor barrier tape,
pressure sensitive on one side.
THE DOW CHEMICAL CO -Types TF600(B), TF604(B),
TF610(B) or Thermax Plus (Blackore).
4. Purlins - No. 16 MSG min gauge steel (min yield strength 50,000 psi).
5. Lateral Bracing - (Not shown) - As required.
Refer to General Information, Roof Deck Construction, (Roofing Materials
and Systems Directory) for Items not evaluated.
'Bearing the UL Classification Mark
ROOF DECK CONSTRUCTIONS (TGKX)
Construction No. 120
Uplift - Not Investigated
Fire - Classified
1. Supports - Structural steel or other materials acceptable to authorities
having jurisdiction.
2. Steel Deck - No. 22 MSG min gauge; min fluted depth 1 1/2 in. with
no perforations. Welded or mechanically fastened to supports in accor-
dance with deck manufacturer's recommendations.
3. Steep Asphalt' - Classified by Underwriters Laboratories Inc. (Roof-
ing Systems) spread at a rate of 12 to IS lb per 100 sq ft. Mechanical
fasteners may be used in lieu of the steep asphalt.
4. Insulation' - Classified by Underwriters Laboratories Inc. under Roof
Deck Construction "Foamed Plastic" for the following manufacturer:
APACHE PRODUCTS CO
CORPORATE -"Apache PYROX", "Apache Tapered PYROX" or
"Apache WHITE LINE" .
ATLAS ROOFING CORP -"ACFoam II", "ACFoam III",
"Tapered ACFoam II", "ACFoam II Ultra", "ACFoam IXF" or
"ACFoam IIXF" .
CARLISLE SYNTEC INCORPORATED - "HP", "HP-W", "HP-
H" or "HP-N".
T~E DO~ SHEMICAL ,~? -Types ,:'ry600", "~,F~?4", "TF,?JO",
Hy-Tec , Energy-Lok, Hy-Tec 2 , Top R-II, Star AP ,
"Hy-Therm AP", "Hy-Therm SP", "Value R", "TRI-Star", "Hy-
Tee RB", "Hy-Tec (Energy Lok) Tapered Roof Insulation", "Hy-
Therm COMPOSITE", "Hy-Therm TAPERED", "Hy-Therm
Nail-Line" or "Hy-Tec Fastnail" .
ENERGY SOLUTIONS INSULATION INC - "ES Foam I"
FIRESTONE BUILDING PRODUCTS CO, DIV OF
BFS DIVERSIFIED PRODUCTS L L C -"IS095+FK",
"IS095+GL", "IS095+GW", "Rhoflex Isocyanurate FK", "Rhof-
lex Isocyanurate GL" or "Rhoflex Isocyanurate GW" .
GAF MATERIALS CORP - EnergyGuardTM RA
HUNTER PANELS -"H-Shield" or Tapered "H-Shield" ,
JOHNS MANVILLE INTERNATIONAL INC -"ENRGY 2 " or
"ENRGY 3", "R Panel"
LOADMASTER SYSTEMS INC -"Loadmaster Polyisocyanurate
Insulation" or "Loadmaster Tapered Polyisocyanurate Insula-
tion"
JOHNS MANVILLE INTERNATIONAL INC - "ENRGY 2
Plus", "ENRGY 2 Gypsum Composite", "Fesco-Foam",
"DuraFoam" or "Nailboard".
POLYGLASS USA INC -"Polytherm" or "Polytherm Compos-
ite"
RMAX INC -"Tapered Thermaroof", "Tapered Thermaroof FA",
"MULTI-MAX-3"(MMA-3) or "MULTI-MAX FA-3"(MMFA-3).
STEVENS ROOFING SYSTEMS, DIV OF
jPS ELASTOMERICS CORP - "Stevens ISO 2000", "Stevens
ISO 2000 - Tapered" or "Stevens ISO 3000" .
THE DOW CHEMICAL CO -"DOW Isocyanurate Board" .
TREMCO INC -"Trisotech G" or "Tapered Trisotech"
Or insulations which are Classified by Undo Lab. (Roofing Materials
and Systems Directory, Roof Deck Construction, Building Units) for the
following manufacturers:
APACHE PRODUCTS CO
CORPORATE-"Apache Millox", "Apache Nail-Line" or
"Apache Nail-Line V"
ATLAS ROOFING CORP - "ACFoam Nail Base Insulation" or
"Vented R" .
CORNELL CORP - "ThermaCal" or "Vent-Top ThermaCal" roof
insulation
FIRESTONE BUILDING PRODUCTS CO, DIV OF
BFS DIVERSIFIED PRODUCTS L L C -"Nailbase",
"IS095+Composite", "IS095+Wood Fiberboard Composite" or
"Rhoflex Isocyanurate Composite"
HUNTER PANELS -"H-Shield-NB", "H-Shield-P", "H-Shield-
WF", Tapered "H-Shield-P" or Tapered "H-Shield-WF" .
RMAX INC -"Thermaroof Composite", "Thermaroof Composite
LOOK FOR THE UL MARK ON PRODUCT
2005 ROOFING MATERIALS AND SYSTEMS DIRECTORY
ROOF DECK CONSTRUCTIONS (TGKX)
FA", "MULTI-MAX-3"(MMA-3) or "MULTI-MAX FA-3"(MMFA-
3).
4A. Insulation - (Optional-Not shown) One layer of min 1/2 in. thick
perlite roof insulation board* placed under the insulation (Item 4)
and/or under the roof covering (Item 5).
4B. Insulation - (Optional-Not shown) Classified by Underwriters Labo-
ratories under the Roof Deck Construction "Mineral and Fiber Boards"
Category, placed over the insulation (Item 4) and under the roof cover-
ing (Item 7).
FIBREX INSULATIONS INC -FBX Baseboard and FBX Cap-
board.
JOHNS MANVILLE INTERNATIONAL INC -"Fiber Glass
Roof Insulation"
OWENS CORNING -"Fiberglas Roof Insulation" or "Fiberglas
Roof Deck Board"
PERFORMANCE ROOF SYSTEMS INC -"Fiberglas Roof Insu-
lation"
SIPLAST INC - "Siplast Fiberglass Roof Insulation"
TRIANGLE DESIGN INC - "Taper-Glas"
4C. Insulation - (Optional-Not shown) Classified by Underwriters Labo-
ratories Inc. under Roof Deck Construction "Foamed Plastic" for the
following manufacturer:
HUNTER PANELS -"H-Shield-F"
Note: Not for use with STEEP Asphalt (Item 3) and asphaltic roof cov-
erings (Item 7).
5. Roof Covering* - A built-up from hot mopped, cold application or
single ply materials Classified by Underwriters Laboratories Inc. (Roof-
ing Materials and Systems Directory, Roofing Systems). Authorities
having jurisdiction should be consulted to which class of roof coverings
will be acceptable in each location.
*Bearing the UL Classification Mark
Construction No, 122
Metal Deck Assemblies
Wind Uplift - Steel Panels - Class 90
Fire Not Investigated
~~
~~~
1. Metal Roof Deck Panels* - No. 24 MSG min gauge coated steel. Pan-
els continuous over two or more spans. End laps to occur over purlins
with panels overlapped 8 in. with lap beginning 4 in. from purlin web
and extending across the purlin flange.
2. Fasteners - For panel to purlin connections to be No. 12-14 by 1 in.,
self-drilling, self-tapping, hex head, plated steel screws with a separate
5/8 in. 00 formal steel washer and a separate neoprene sealing
washer. Spacing to be in a 4-1/2-4-1/2-4-1/2-4-112 in. pattern with fas-
teners located 2-114 in. from the center line on both sides of each major
rib. Spacing at end laps to be the same.
Fasteners for panel to panel connections to be No. 14 by 3/4 in. Type AB
self-tapping, hex head plated steel screws with a separate 5/8 in. 00
formed plated steel washer and a separate neoprene sealing washer.
Spacing to be 18 in. O.C. with one located approx even with the purlin
web and one additional fastener located 4-112 in. from the first at the end
lap.
As an alternate fastener - for panel to purlin connections - No. 14 Type
AB, self-tapping, hex head, plated steel screws with a separate 5/8 in. 00
formed plated steel washer and a separate neoprene sealing washer may
be used. Length to be 3/4 in. when using 3 in. thick insulation and 1 in.
when using insulation over 3 in. Spacing of alternate fasteners to be the
same as described above.
Pilot holes - for panel to panel fasteners to be 3/16 in. diam.
3. Insulation - (Optional) - Any compressible blanket insulation 4 in.
max thickness before compression.
4. Purlin- No. 16 MSG min gauge steel. (min yield strength 42,000 psi).
5. Lateral Bracing - (Not Shown) as required.
Refer to General Information, Roof Deck Construction (Roofing Materials
and Systems Directory) for items not evaluated.
*Bearing the UL Classification Mark
ROOF DECK CONSTRUCTIONS (TGKX)
Construction No. 123
Uplift - Not Investigated
Fire - Classified
573
1. Supports - Structural steel or other materials acceptable to authorities
having jurisdiction.
2. Steel Deck - No. 22 MSG min gauge: min fluted depth 1-1/2 in. with
no perforations, welded or mechanically fastened to support in accor-
dance with deck manufacturer's recommendations.
3. Adhesive* - Classified by Underwriters Laboratories Inc. (Roofing
Materials and Systems Directory, Roof Deck Constructions.) Spread at
the rate specified in the individual classifications of the following
manufacturers:
FORTIFIBER CORP -"402"
VERSICO INC -"Vapor Mate"
This adhesive is not used when the vapor barrier is omitted.
4. Vapor Barrier* - Classified by Underwriters Laboratories Inc. (Roof-
ing Materials and Systems Directory, Roof Deck Construction, Sheath-
ing Materials) manufactured by:
FORTIFIBER CORP -"PYRO-KURE 600" or "Vaporstop 398100"
VERSICO INC -"Vapor Mate 200"
This vapor barrier may be omitted from the construction.
5. Adhesive* - Classified by Underwriters Laboratories Inc. (Roofing
Materials and Systems Directory, Roof Deck Constructions.) Spread in
ribbons spaced 6 in. OC at the rates specified in the individual classifi-
cations of the following manufacturers:
BMCA INSULATION PRODUCTS INC -"R-907-T"
FORTIFIBER CORP -"402"
REPUBLIC POWDERED METALS INC -"Insulation Adhesive"
TREMCO INC -"FAS-N-FREE"
VERSICO INC -"Vapor Mate"
Mechanical fasteners may be used in lieu of this adhesive.
6. Insulation* - Classified by Underwriters Laboratories under Roof
Deck Construction "Foamed Plastic" for the following manufacturers:
APACHE PRODUCTS CO
CORPORATE-"Apache PYROX", "Apache Tapered PYROX" or
"Apache WHITE LINE"
ATLAS ROOFING CORP -"ACFoam II", "ACFoam II Ultra",
"ACFoam III", "Tapered ACFoam II", "ACFoam IXF" or
"ACFoam IIXF"
CARLISLE SYNTEC INCORPORATED - "HP", "HP-W", "HP-
H" or "HP-N"
TJ;IE DO~ ~HEMICAL ,~C? -Types .:'~~600", "~,F~~4". "TF,?lO",
'Hy-Tec, Energy-Lok, Hy-Tec 2 , Top R-II, Star AP ,
"Hy-Therm AP", "Hy-Therm SP", "Value R", "TRI-Star " , "Hy-
Tee RB", "Hy-Tec (Energy Lok) Tapered Rooflnsulation", "Hy-
Therm COMPOSITE", "Hy-Therm TAPERED", "Hy-Therm
Nail-Line" or "Hy-Tec Fastnail"
ENERGY SOLUTIONS INSULATION INC -"ES Foam I"
FIRESTONE BUILDING PRODUCTS CO, DIV OF
BFS DIVERSIFIED PRODUCTS L L C -" IS095+FK",
"IS095+GL", "IS095+GW", "Rhoflex Isocyanurate FK", "Rhof-
lex Isocyanurate GL" or "Rhoflex Isocyanurate GW"
GAF MATERIALS CORP - EnergyGuardâ„¢ RA
HUNTER PANELS -"H-Shield" or Tapered "H-Shield"
JOHNS MANVILLE INTERNATIONAL INC - "ENRGY 2" or
"ENRGY 3", "R Panel"
LOAD MASTER SYSTEMS INC -" Loadmaster Polyisocyanu-
rate Insulation" or "Loadmaster Tapered Polyisocyanurate Insu-
lation"
STEVENS ROOFING SYSTEMS, DIV OF.
JPS ELASTOMERICS CORP - "Stevens ISO 2000", "Stevens
ISO 2000 - Tapered" or "Stevens ISO 3000"
RMAX INC -"Tapered Thermaroof", "Tapered Thermaroof FA",
"MULTI-MAX-3"(MMA-3) or "MULTI-MAX FA-3"(MMFA-3).
THE DOW CHEMICAL CO -"DOW Isocyanurate Board"
Or insulations which are Classified by Underwriters Laboratories
(Classified Roofing Materials and Systems Directory, Roof Deck Con-
LOOK FOR THE UL MARK ON PRODUCT