HomeMy WebLinkAbout11380-Building maintenance (porch)
G
OSHKOSH
ON THE WATER
Issue Date 7/13/2006
~.
,
Address
Sent to
Introduction
INSPECTION SERVICES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance Date 8/12/2006
Compliance No
119W9THAVE
Name
BRUCE/MELINDA GOSDECK
State Zip Code
WI 54902 - 6053
Address
119 W 9TH AVE
City
OSHKOSH
l!J Owner
U Required for Occupancy Occupancy Single Family
he following violations were noted at the final inspection of the front porch landing and steps.
Item # Code Zoning Code Compliance No Compliance Date 08/12/2006
Description he landing is only allowed to protrude 4' into the required setback area. The landing measures over 5' and is too large.
07/13/2006
Last
Updated
Item # 2 Code COMM 21.04 Compliance No Compliance Date 08/12/2006
Description Handrails or guardrails shall be provided on all open sides of stairs consisting of more than 3 risers. Handrails and guardrails shall be
constructed to prevent the through passage of a sphere with a diameter of 4" or larger.@@Currently the spindles are spaced too far apart.
07/13/2006
Last
Updated
Item # 3
Description
07/13/2006
Last
Updated
Item # 4
Description
07/13/2006
Last
Updated
Code COMM 21.04 Compliance No Compliance Date 08/12/2006
Handrails must be graspable and symmetrical about the vertical centerline to allow for equal wraparound of the thumb and fingers. Handrails
with a round cross sectional gripping surface shall have a maximum whole diameter of 2". Handrails with a rectangular cross sectional
;jripping surface shall have a maximum perimeter of 61/4" with a maximum cross sectional dimension of 2 7/8".
.
Code COMM 21.04 Compliance No Compliance Date 08/12/2006
~reads and Risers. Risers may not exceed 8 inches in height measured vertically from nosing to nosing, with any variation in uniformity in I
each tread or riser not varying by more that 3/16 inch for the entire stairway.@@Currently the risers and treads are not uniform and the bottom I
iriser is over the allowed 8". I
I I
11380
Page 1 of 2
G
OSHKOSH
ON THE WATER
Issue Date 7/13/2006
INSPECTION SERVICES DIVISION ROOM 205
DEPARTMENT OF COMMUNITY DEVELOPMENT
CORRECTION NOTICE
CITY OF OSHKOSH
215 CHURCH AVE
PO Box 1130
OSHKOSH WI 54903-1130
Compliance Date 8/12/2006
Compliance No
Address
119 W 9TH AVE
Sent to
~ Owner
Name
BRUCE/MELINDA GOSDECK
Address
119 W 9TH AVE
City
OSHKOSH
State Zip Code
WI 54902 -6053
Introduction
rrhe following violations were noted at the final inspection of the front porch landing and steps.
U Required for Occupancy
Occupancy Single Family
Item # 5
Description
Code COMM 21.04 Compliance No Compliance Date 08/12/2006
IGuardrails. All openings between floors, and open sides of landings, platforms, balconies or porches that are more than 24" above grade or a
floor shall be protected with guardrails that measure a minimum of 36" above the floor it serves.@@The short sections of guardrail along the
~ides of the stairway are not 36" in height.
07/13/2006
Last
Updated
Summary Please correct the above violations and request a re-inspection at 236-5128 within the next 30 days. Office hours are
Monday-Friday 7:30-8:30am and 12:30-1 :30pm. If you have questions feel free to contact me at 236-5036.
Violations must be corrected and approved within 30 days unless otherwise noted. Call for reinspections prior to concealment
and/or occupancy. Upon completing the corrections, the owner/contractor/agent must sign and date at the bottom of this notice
and return it to the Inspection Services Division by the Compliance Date of 8/12/2006
Office hours for obtaining permits are Monday through Friday 7:30-8:30 a.m. and 12:30-1 :30 p.m. or by appointment. To schedule
inspections please call the Inspection Request line at 236-5128 noting the address, permit number (when applicable), and the
nature of what ~ed~ to be inspecte<J,.
Signature ----}J\ ~J. (~ Date '(/c.(;67.p
Inspected by: Nicole Krahn 236-5036 nkrahn@ci.oshkosh.wi.us
I hereby certify the violations listed on this report have been corrected in compliance with the applicable codes.
Print Name
Company
Signature
Date
Also Sent to: U Bldg
U Elec
U HVAC
U Plbg
U Designer
U Other
U Inspector
11380