HomeMy WebLinkAbout0119333-Plumbing
e,
OSHKOSH
ON', ß'iVATER
Job Address 95 DAWES ST
CITY OF OSHKOSH
PLUMBING PERMIT. APPLICATION AND RECORD
No
119333
Contractor MARSHALL PLUMBING
Bathtub
Whirlpool
Lavatory
Toilet
Res. Sink
Bar Sink
Water Heater
Site Drain
Roof Drain
Misc.
Fixtures
3 Shower
Floor Drain
----1 Water Softner
----1 Local Waste
Clothes Wshr
Bidet
3 BeerTap
Lab Sink
Sterilizer
Dip Well
Drink Ftn
Owner TRI STAR LIVING
Create Date 05/04/2006
Plan G2-185-0506-P
Category 410 - Residential-Interior
Wail.SI.
Ice Chest
3 Exam Sink
Sculry Sink
Hand Sink
Plaster Sink
Surgeons Sink
F Prep Sink
Serv Sink
Shamp Sink - Coffee Maker
Flr/Wst Sink Int Grease Trap
Ext Grease Trap -
RPZ Valve
Eye Wash Statn
6 Wtr Sewer Mtrs
Deduct Meters
Wtr Usage Mtrs
Catch Basin
Wash Ftn
Urinal
Standp Rec
Ice Maker
Gar Drain
Soda Disp
NEW MULTI FAMILY 3-UNIT TOWNHOUSE INTERIOR PLUMBING, WATER AND SANITARY LATERALS.
Size Material Type # Conn. Type
Sanitary Sewer 4" Plastic Lateral 1 New
Storm Sewer
Water Service 1-1/4" Copper Lateral 1 New
Parcelld #
0102430000
Use/Nature
of Work
Valuation
Issued By
9 Lndry Tray
9 Disposal
3 Dishwasher
Sump Pump
3 Classrm Sink
Breakrm Sink
Ejector/Grind
$74,000.00
$0.00
Permit Fees
$415.00 0 Permit Voided I
Date 05/04/2006
Plan APproval
In the performance of this work, I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the
easement holder(s) and to secure any necessary approvals before starting such activity.
Signature
Date
Address N202629TH LN
Agent/OWner
REDGRANITE
WI 54970 - 0000
Telephone Number 361-4846
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
~
OJHKOJH
City of Oshkosh
Inspection Services
215 Church Ave., PO Box 1130
Oshkosh, WI 54902-1130
(920) 236-5049 (920) 236-5106 FAX
ON THE WATER
May 4, 2006
Marshall & Son Plumbing
N2026 29th Lane
Redgranite, WI 54970-8562
Ref: Plumbing Plan Approval:
.,F'i3,.~ç:§J.,..f.",..k..k¡¡".(3.;\JD.j!JÇl~Q.Q,~!L. S"".¥ )...
:'95 Dâwes st Oshkosh WI 54901"
Plan ID#Ftle-G2-185:ö'5Ó6-P'-~
Dear Sirs,
Examination of the plumbing plans and specifications for this project has been completed. In
accord with Chapter 145, Wisconsin Statute, and COMM 81 through 85, Wisconsin
Administrative Code, the plumbing plans and specifications are approved contingent upon
compliance with the stipulation(s) noted below.
1. A cleanout shall be provided near the junction of a building drain and a building
sewer. The cleanout shall be located within 5 feet of where the building drain and
the building sewer connect. COMM 82.35 (3)(e)
2. All gravity horizontal drains within or under a building shall be accessible through a
cleanout. The developed length of drain piping between cleanouts may not exceed
75 feet. Comm 82.35(3)(a)
3. Storm building sewers 12" or larger in diameter shall be provided with manholes or
storm drain inlets with an inside diameter of at least 36". Comm 82.35(3)(c)2
4. Minimum diameters and maximum length if individual, common, branch, and circuit
vents and vent headers shall be sized from Table 82.31-3. Comm 82.31(14)
In the event installation of this plumbing system has not commenced within two years from this
date, this approval shall become void. A new application accompanied by full examination
fees shall be filed and an updated approval received before work may commence.
In granting this approval, the City of Oshkosh or its representative does not hold itself liable for
any defects in plans or specifications, plan omissions, examination oversight, construction or
any damage that may result in or after installation. The City of Oshkosh reserves the right to
order changes or additions should conditions arise making this necessary.
It shall be necessary for the installing plumber to obtain a plumbing permit from the City of
Oshkosh before proceeding with actual installation of this plumbing system or any of its parts.
Respectfully,
Paul Wolf,
Plumbing Inspector
e
OSHKOSH
ON THE WATER
Job Address
APproval Type
Oshkosh Plan Approval Form
95 DAWES ST
Plumbin9
Submitte~s Name MARSHALL PLUMBING
Address N2026 29TH LANE
Owner Name
Approval Number
1609
Plan G2-185-0506-P
REDGRANITE
8562
TRI STAR LIVING
WI
54970
Address 51051 AH MAYTAH RD
Oshkosh
0
WI
54901
Fee
Type of Plan 3-UNIT TOWNHOUSE & STORM UTILITIES
05/04/2006
$330.00
Date Received
Date APproved
5/4/2006
Fixture Listing
'Date' May4,2006
Name: MARSHALL PLUMBING
Project: 3-UNIT TOWNHOUSE
Street: N2026 29TH LN
Street: 95 DAWES ST
City: REDGRANlTE
City:
OSHKOSH
Non Public Use Fixtures
3 Automatic Clothes Washer 3.00 3.00 4.50
3 Dishwashing Machine 3.00 .00 3.00
3 Kitchen Sink 3.00 3.00 4.50
3 Lavatory 1.50 1.50 3.00
3 Water Closet, gravity type flush tank .00 6.00 6.00
3 Bathtub, lavatory and water closet - FT group 6.00 10.50 12.00
3 Shower Stall, lavatory and water closet FT - group 4.50 9.00 10.50
Hot
Cold
Total
Total Water Supply Fixture Units
21.00
33.00
43.50
25.4 Gallon per minute demand of the building. Predaminatly Flush Tank
23.3 Pressure available for unifann loss. For the table use - 24.0
Maximun AUowable load for Copper Tube Type L, ASTM 888
Nominal Size 1/2 5/8 3/4 1 11/4 11/2 2 21/2 3 4
Actual!. D. .545 0 .785 1.025 1.265 1.505 1.985 2.465 2.945 3.905
Value afC 130 130 130 130 130 130 130 130 130 130
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 5.5 0 12 20.5 31 44 77 1I9 169 298
Maximum FM WSFU 0 0 4.5 7 15 36 136 356 692 1787
Maximum FT WSFU 6.5 0 16.5 31 57 106 260 470 747 1787
WATER DISTRIBUTION DATASHEET
'Dat.: May 4, 2006
Name: MARSHALL PLUMBING
Project: 3-UNIT TOWNHOUSE
Street: 95 DAWES ST
Street: N2026 29TH LN
City: REDGRANITE
City:
OSHKOSH
1. ~ GaBon per minute buiding demand, predominatly Flush Tank.
2. ~ Low pressure at the Main in the Street.
3. ---.1& Lb loss ftam a 7.0 ft difference in elevation ftam Main in the Street to the Water Meter.
4a.~ Lb loss ftam a 70.0 ft I II4" Copper Tube Type L ASTM B88 water service ftam the Main in the Street to the Water Meter.
Pressure loss detemined using a C value of 130, inside diameter of 1.265 and a velocity of 6.5 ft per sec.
4b.---.:!! No 2nd part water lateral.
5. --2:1 Lb loss ftam a 3/41n Meter
6. ~ Lbs of pressure available at the Water Meter. This value is entered in (B) below.
The (A) value listed below is detennined by using the following fonnula, then rounding the result up.
A~ B-(C+D+E) x 100
F
A. ----11 Pressure available for uniform loss (psi/IOO feet ofpipe).
B. ~ Lbs of pressure available at the Water Meter.
c. ~ Pressure needed at the controlling flxture. PB TIS VALVE
D. ~ Lb loss resulting ftam a 16.0 ft difference in elevation ftam the Water Meter to the controlling flxture.
E. --.J! Lb pressure loss due to a no pressure loss devices serving the controlling fixture.
F. ~ Ft Developed length ftam the 44.0 ft actual length of piping ftam the Water Meter to the controlling fixture.
Maximun Allowable laed for Copper Tube Type L, ASTM B88
Nominal Size 1/2 5/8 3/4 I lIl4 I 1/2 2 2 II2 3 4
Actual I. D. .545 0 .785 1.025 1.265 1.505 1.985 2.465 2.945 3.905
Value afC 130 130 130 130 130 130 130 130 130 130
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 5.5 0 12 20.5 31 44 77 119 169 298
Maximum FM WSFU 0 0 4.5 7 15 36 136 356 692 1787
Maximum FT WSFU 6.5 0 16.5 31 57 106 260 470 747 1787
Fixture Listing
. Da!e:May4,2006
Name: MARSHALL PLUMBING
Project: 3-UNIT TOWNHOUSE
Street: N2026 29TH LN
Street: 95 DAWES ST
City: REDGRANlTE
City:
OSHKOSH
Non Public Use Fixtures
3 Automatic Clothes Washer 3.00 3.00 4.50
3 Dishwashing Machine 3.00 .00 3.00
3 Kitchen Sink 3.00 3.00 4.50
3 Lavatory 1.50 1.50 3.00
3 Water Closet, gravity type flush tank .00 6.00 6.00
3 Bathtub, lavatory and water closet - FT group 6.00 10.50 12.00
3 Shower Stall, lavatory and water closet FT - group 4.50 9.00 10.50
Hot
Cold
Total
Total Water Supply Fixture Units
21.00
33.00
43.50
25.4 Gallon per nrinute demand of the building. Predaminatly Flush Tank
23.3 Pressure available for uniform loss. For the table use - 24.0
Maximun Allowable load for Crosslinked Polyethylene (pox) Tnhing ASTM F876
Nanrinal Size 1/2 5/8 3/4 I 11/4 11/2 2 21/2 3 4
Actual I. D. .485 .584 .681 .875 1.069 1.263 1.653 0 0 0
ValueafC 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 4.5 6.5 9 15 22 31 53 0 0 0
Maximum FM WSFU 0 0 0 5 7 15 56 0 0 0
Maximum FT WSFU 5 8 11.5 21.5 35 57 140 0 0 0
WATER DISTRIBUTION DATASHEET
'Dale: May 4, 2006
Name: MARSHALL PLUMBING
Project: 3-UNIT TOWNHOUSE
Street: N2026 29TH LN
Street: 95 DAWES ST
City: REDGRANITE
City:
OSHKOSH
I. ~ Gallon per nUnute buiding demand, predaminatly Flush Tank.
2. ~ Low pressure at the Main in the Street.
3. ~ Lb loss from a 7.0 fr difference in elevation from Main in the Street to the Water Meter.
4a. ~ Lb loss from a 70.0 fr I 1/4" Copper Tube Type L ASTM B88 water service from the Main in the Street to the Water Meter.
Pressure loss detemined using a C value of 130, inside diameter of 1.265 and a velocity of 6.5 ft per sec.
4b.--.J! No 2nd part water lateral.
5. ----'1,1 Lb loss from a 3/4in Meter
6. ~ Lbs of pressure available at the Water Meter. This value is entered in (B) below.
The (A) value listed below is detennined by using the following formula, then rounding the result up.
A~ B-(C+~+E) x 100
A. ----11 Pressure available for uniform loss (psil100 feet of pipe).
B. ~ Lbs of pressure available at the Water Meter.
C. ~ Pressure needed at the controlling fixture. PB TIS VALVE
D. ~ Lb loss resulting from a 16.0 ft difference in elevation from the Water Meter to the controlling fixture.
E. ----:!! Lb pressure loss due to a no pressure loss devices serving the controlling fixture.
F. ~ Ft Developed length from the 44.0 ft actual length of piping from the Water Meter to the controlling fixture.
Maximun Allowable load for Crosslinked Polyethylene (pex) Tubing ASTM F876
Nominal Size 1/2 5/8 3/4 I 11/4 11/2 2 21/2 3 4
Actual!. D. .485 .584 .681 .875 1.069 1.263 1.653 0 0 0
ValueafC 150 150 150 150 150 150 150 150 150 150
Velocity in ft per sec. 8 8 8 8 8 8 8 8 8 8
Maximum Gpm 4.5 6.5 9 15 22 31 53 0 0 0
MaJdmum FM WSFU 0 0 0 5 7 15 56 0 0 0
Maximum FT WSFU 5 8 11.5 21:5 35 57 140 0 0 0
WATERCALCULATIONWORKSHEETFOR pl\(ze_iDL- 'F Lu:.-
NAMElAIXJI<ESS OF PROJECr
L.l,- \ T ""3
INFORMATION REQUIRED TO CALCULATE WATER SERVICE SIZE
1.
2.
3.
4.
5.
. I,.
Demand of building in gallons per minute. WSFu's4.3 iLk- ~ (GPM) ¿ fp
Difference in elevation from main or extemal pressure tank to building oontrol valve. (feet) ~
Size of the water meter. nMhenapplicable) 5/8" 3/4" IV 1" 1-112" 2" 3" 4" 6'
", ~ b. ~ ~ ~ ~ ~ -'
Developed length from main or extemal pressure tank to building control valve. (feet) ì 0
Low pressure at main in street or extemal pressure tank. (psig) ~
""'ÞI..~
CALCULATE WATER SERVICE PRESSURE LOSS
6.
7.
Low pressure at main in street ÿ; extemal pressu: tank. (value of # 5 above)
Water service. (t;\',meter iS~' Material is -.C1 f' ¡z.. L .. Pressure loss'
per 100 ft = ...; ~ psi. X .-L2-(decimal e<¡UiValent of service length. i.e.; 65ft = .65)
(Subtract line 7. from line 6.) subtotal
8.
Determine pressure gain or loss due to elevation,
(multiply the value of # 2 above by .434)
value of '8'
9.
Available pressure after the bldg. oontrol valve. (Subtract or add line 8. Enter in '8".)
subtotal
CALCULATE THE PRESSURE AVAILABLE FOR UNIFORM LOSS (VALUE OF "An)
B.
C.
Available pressure after the bldg. control valve. (from '9' above)
Value of "B'
D.
Pressure loss of water meter (w1en meter is required or installed) Value of 'C'
¡ !6Pv""
(Subtract line C. from line B.) subtotal
¡~=~I~~~~~~I~gfixtUre. 6 i.¡..ot..<..-¡¡;:.(Z /Tvß ) Valueof'D'
, (Subtract the value of D.) subtotal
bb
"Z.Æ3
~57-1-
~
'54..3'
54-3
-L.q -
3$.-?-
"'ZD-o
:'5'5,;£
Difference in elevation between the. building control valve
and the controlling fixture in feet---!-LX .434 psi1ft. Value of'E' "7.0
(Subtract the value of E.) subtotal ""2.;"-..- '2..
Developed len°1' from building control valve to controlling ( f
fixture in feet~"t _X 1.5 Value of"G' of<?
(Water distribution piping material is P JZ:..;<" (Di~ide by the value of G.) subtotal :..::::~~
T'"i?V L
E.
F.
Pressure loss due to water treatment devices, instantaneous
water heaters and backflow preventers which serve the
controlling fixture.
(Pressure loss due to )
(Subtract the value of F.)
5ubtotal
Value of 'F"
G.
Multiply by
A
Pressure available for uniform loss
"An ~
S60""79(RSIO2
'U. ?..
.-1QL
~?:j_7