HomeMy WebLinkAbout0119318-Plumbing
e
OSHKOSH
ON THE WATER
Job Address 149W24THAVE
Contractor J RASMUSSEN PLUMBING INC
Bathtub
Whirlpool
Lavatory
Toilet
Res. Sink
Bar Sink
Water Heater
Site Drain
Roof Drain
Misc.
Fixtures
Use/Nature
of Work
Valuation
Issued By
CITY OF OSHKOSH
No
119318
PLUMBING PERMIT. APPLICATION AND RECORD
Owner 149 W 24TH AVENUE LLC Create Date 05/04/2006
Category 410- Residential-Interior Plan
WaterSoftner Wait St. Shamp Sink - Coffee Maker
Local Waste Ice Chest FlrlWst Sink Int Grease Trap
Clothes Wshr Exam Sink Catch Basin - Ext Grease Trap
-
Bidet Sculry Sink Wash Ftn RPZ Valve
Beer Tap Hand Sink Urinal Eye Wash Statn
Lab Sink Plaster Sink Standp Rec Wtr Sewer Mtrs
Sterilizer Surgeons Sink Ice Maker Deduct Meters
Dip Well F Prep Sink Gar Drain Wtr Usage Mtrs
Drink Ftn Serv Sink Soda Disp
1 Shower
Floor Drain
1 LndryTray
1 Disposal
Dishwasher
Sump Pump
Classrm Sink
Breakrm Sink
Ejector/Grind
NEW BATHROOM ADDITION IN APT 101 "DEBIT ACCT
Size Material Type # Conn. Type
Sanitary Sewer
Storm Sewer
Water Service
Parcelld #
1411450100
$3.000.00
$0.00
$21.00 0 Permit Voided I
Permit Fees
Plan Approval
Date 05/04/2006
In the performance of this work, I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which It is not a party, if you perfonn the work
described in this pennit application within an easement, the City strongly urges the permit applicant to contact the
easement holder(s) and to secure any necessary approvals before starting such activity.
Signature
Address 1914 GREENBRIAR TRL
Date
AgenUOwner
OSHKOSH
WI 54904 - 0000
Telephone Number 920-233-6747
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not perfonmed within two business days from the time the project is ready.
:::. ,05/05/2005
::: .
10:21
2335747
J RASMUSSEN
PAGE 01/09
Rasmussen plumbing, Inc.
Jeff Rasmussen
Master Plumber #223251
1914 GreeJlbriar Trail
Oshkosh, WI 54904-8887
=
-~
lIIIOI;:: ~
Phone: (920) 233-6747
Fax: (920) 231-1289
E...rnail: rastn\\ss@charter.net.
DATE: b- S - ~ l Cn..~ ofl'ax R;:clVed Req"..t.d:l
TIME: /6 ~Jo 1<'7'- _ _ ..-------LJ YES_ ~
NO. OF PAGES (Including Cover poge): _3
TO~ t! fvD (~
FROM: 5" :!:a - 3" J ~ I\o.-'-'-.l J ---- f lL a;... " -
MESSAGE:
~07"/;'~--~'~ ~~
...,.'D"~.'.. .. '.. ..~.~. ..... ............ .......
_ ..___m.'~,_"""W"~ ','_' -__",,~"';''''''':-''";:;2'''''':,;'~';''.~:'~~'~' ,',"', ,::,;".:;:~:,-:~:'~0:,,":'~'~,>',"~:''':;:':; :;,'\-_::';':'~
"LJ....",..,._-J;d.. ......---........... . .~.........~
,_( _ ',_ _ ",__...;. :.7""- ',,'-
d.t:.t L It r'."'- A# ,1--1 ~~
'':'~'''-'
"-:~\;:1~
4ff /lJ l
~
r1
-
---'~
~--
05/05/2005 10:21
2335747
J RASMUSSEN
PAGE 02/09
~]S~~f~';~~9~~~A SHEET
~!IIUllli Series SSS Intumescent Sealant
I~~~~I
~F1Ll' WID OIl CAvrrY IlAlERllU CI.~At",1I!11IY
lIIDERI'IRII1i"" LollOllO_lea IIlC,. fCIIl uftll
, ilL IN 1l111911...._!'IltA'IlON
, Y FTM:e8TOPJl"f!fitlMI!l.
1111 BFe ... FmI! RESISTANCE DIRE<mJRY
~ ..ur.... CLAS!Il"ED P.... WIll, "" ""VITY ....TallolI.8
~ fOR"'EIll_-l'ENrnUmllOl~all8-
n IMIJBCB. 9EEULllIIlIIcftlIYOP~
C T CERlIFlED FOR IW'AfJA ollll
IA. _ III!S181J>.NCE DIIlECToPV
~
APPIIOVElI
FEATURES
. Water.BeAod for easy
Installation. cleanup, and
dlspo$<ll.
. Two-Suge Intum.-cence
features extremely fast and
drrectlonallzed expansion.
. Endothennlc FII"r9
absorb heat & relerjlse water.
.. High Sollde Pormula means
no shrinkage!
. Sandable & Palntable
(when dry)
... Wstar-Reslstant: Will not
re-emulslfy when dry!
... Sate: Low VOCs, No Solvents
. Red Color for easy
Identification and Inspection.
.. MultI VI~lty Grade
meanS excellent caulking
propertie!'; along with high bllild
capabilities.
. ~lIent Smoke Seal
I~J Spllclfled Technologies, Inc,
1. PRODUCT DESCRIPTION
SpecSeal@SerieS SSS Sealant Is a latex based, high solidsfirestop compound. This
material, when properly Installed, will effectively seal penetration openings ageinst
the spread of fire, smoke, toxic gasses and water.
SpecSeal<ID Series SSS Sealant features STI's patented and proprietary two.stage
intumescent technology. When exposed to high temperatures or flre. this material
expands aggressively in a highly directlonelized fashion to quickly close off voids left
by the burning or melting of combustible materi;:lls.
SpecSeal@SeriesSSSSealant'sunique multi-viscosity formula yields a singre grade
that has excellent caulking properties as well as high build properties on vertical or
overhead surfaces, This single grade may be pumped, caulked (standard cartridge
or bulk loaded), knifed or troweled. In addition, SpecSeal@ SSS does not contain
PCB's or asbestos.
SpecSeal@ Series SSS Sealant is storage stable (when stored 61ccording to the
manufacturer's recommendations) and will not separate nor shrink when dried.
SpecSeal@ Serles SSS Sealant will adhere to all common construction and penetrant
materials and contains no solvents making it safe for use with most plastics,
2. APPLICATIONS
See Table A for a summary application list.
SpecSeal@ Series SSS Sealant is used to seal through-penetrations as well as
construction gaps and blank openings, Series SSS has been tested tor use with
metallic penetrants up to 30. (762 mm) trade size. This product is also used with other
SpecSeal@ Products such as SpecSeal@ Firestop Collars Glnd Wrap Strips.
3. PHYSICAL PROPERTIES
See Table B.
4. PERFORMANCE
SpecSeal@ Series SSS Sealant Is the basis for systems that meet the exacting criteria
of ASTM EB14 (Ul1479) as well as the time-temperature requirements of ASTM E119
(UL263). Systems have been tested foral! common forms of oonstt1.lction and most
common penetrants with ratings up to 4 hours. STI firestop systems are designed to
maximize the fire resistanoe of the seal by not only sealing off the spre61d offire and hot
gasses but arso by minimizing the amount of heat conducted through the assembly,
5. SPECIFICATIONS
The firestopplng seslant shall be a one-parI. twl>-stage intumescent latex compound. The
sealant when expOSed to high heat or flame shall be capable of expanding a mInimum of
8 times. Range of conlinuing expBnslon shall be from 2300F to >l,OOO.F (1100C to 53S"C),
The sealenl: shall be thixotropiC and shall be capable of caulking or troweling onto vertIcal
surfaces or overhead. The sealant Shell be UL Classified and/or FM System!; Approved and
lestoo to the reQuirements of ASTM F.814 (UL 1479).
SPECIFIED DIVISIONS
DIV. 7 07840
DIV. 13 13900
DIV. 15 15250
Through-Penetration Firestopplng
Special Construction FIre Suppression & Supervisory Systems
Meohanlcal Insulation - Fire Protection
DIV.
16
16050 BaSic Electrical Materisl$ & Methods
STI Product Data She<>t . SllI1116 ssg InlII""",alltlt halaftt . 1'00.5001 001?004
www.Btlflre3!op.c;Qm . Toll Free Boo..m.l' eo
05/05/2005 10:21
2335747
Table A: APPLICATIONS
Tested & cla.sllled for 'Ir.
Resistance
, Metallic: PIpes Inoluding steel, Iron, or
copp@r pipe and tubing througl1 all
oommon oonstructlons.
. Moamet.me Plpos, COftdults
&Tublng Including PVC, CF'VC. PVDF.
PEX, PEX-AL.PEX. ASS, PB through all
common oonstructions.
- C.bI8, Cable Tmys & Bus Duct
. HVAC DlICtwork
. In.ule-tad Pip..
, Multl-Setvlco Penetrations
including AC line sets. electrical.
telephone, orN service entrance and
IntEl riQr penetratIons.
. COmpl.... Wood Floor are.topplng
p."hga {or electrical, plumbing, HVAC.
TV and telephone.
Table B;
PHYSICAL PROPERnES
Product M..... Series SSS Seal~nt
Color Red
Odor Mild Latcl<
D&nslty S.4 Lb/Gal (1.13 kg/L)
Solids eoo/. i 2%
pH 8.~
&pa",*-, Begins 230'F (l1Q"Cl 1st Stage
350'F (177"C) 2nd Stage
~ R1119 230'Fto >1.000"F
(110'C to > 538'C)
VoIIIme I!xp8nsIon > 500% Free E:lq:ms!on
M_.ln.Servlco 'hIIIp. 120'F (4S"C)
Fhllm8 Spread O'
Smok~ Development 10'
STC Rating 51
voe ConterrtT' 0.1 Bibs/gel (22.0 g/l)
. Tosr.,(] IoASTM EM (liL12a) ot 14% surrace O0ll9r~Il"
rmodlfl!>d t<Mll for seslent9 91'<1 o~ulk.!t)
"A..<;TM D39130 and ErA Federsl Fl<lmrnnoo Malhad 2~
J RASMUSSEN
PAGE 03/09
Shown below and on the following page are justa few of the most common
app/IcJJtlonS for Specge8I SerlsS SSS Se;IIant. CO/7$ult the Technical Library at
WININ.stlflrestDp.com for O~ 200 8V8ilable designs utilizing thIs product.
I F1g.1l MIn'ALUC PIPE PENETRAnONS.
. CONCRE'TE/MASONRY FLOORS & WALLS
..
UL SYSTEM C-AJ-1079
F Rating: 4 Hr . T Raling: 0
Steel or Iron Pipe: 24', CopparPlpe 6'
Amulus: !'oint Conl!lCl to 4' . Sealant Depth: 1/2"
Forming M$erial: Nom 4 pef Mineral Wool
Thickness: 1-112" rer 6' Steel or Iron Pipe
S'w 4' Copper or 6' Imn or Slee! Pipe
'f
..
UL SYSTEM C-AJ-121'7
F RatIng: 4 Hr ' T Ratlng; 0
Steel or Iron Pipe: 30". Copper Pipe 6'
AnnvlLIS: Point Ganlact to T . Sealant Depth: 1 IT
Forming Materiel: NO/Yl 4 pcf Mineral Wool
l1ghlly ~ to B ~ Depth.
Fig. 2:
INSUU,TED METALLIC PIPE PENETRATlONS-
CONCREtEJMASONRY FLOORS & WALLS
UL SYSTEM C-U-SOB7
F Fladng: :il Hr . T Rating: 1
Slrel or Iron Pips: 24"
Insulated wlIh 2' THOl< Fiber Glass or Mineral Wool Pipe Il1!'lulllllon
Annulus: 112" to 1-112' . Sealant Depth: 1 t:t
Forming Materlal: Nom 4 pet Minoral Wool llQhtty Packed 10;;4' Deplh.
Table Ci SEALANT REQUIREMENTS IN CUBIC INCHES PER 1/4 INCH OF INSTAUED DEPTH"
Pip" SIll:. D..II'l..... of ~,!I_llItI (In.)
... . ...
..." D.D. 1.-' 2.0 3.0 4,,0 11.0 6.0 7,0 8.0 10 12 ~ 2S
O,~C ."0:840 O.~ 0.6 1.6 :3.0,:4.1'!. 6,9 9.6 1~.4 19.5 2B.1 ._1~ 1~~.6
1.~_. 1.315 0.1) "0.4 ,."..,~ 2.8 4,EL 6,7 g,:3' ""'1i..:? 1~.3 27..Q,'~:,,,_~~ 132.4_
1.!5" 1.900 .. ____ 1,1 2.'1 4.2 6.4 B.e 11,9 1B.9 2!-.E1 37,R 132:0
,,- 2..375 0.7 . ..~.O ~.8 8.0 8.t; 11.5 l.a.!; _ 27.2 37.4. _!a1.5
2.5" 2.875 0.1 1.5 ~.3 5:;;:,:. _~ 10.9 1tl..!L. 26.7 36.9 1~-".L
SA 3.500'- 0.7 2.5 ..~.?. 7.2 1Q..2 17.2 25.8 3ftJ 130.;L
3~5.' 4~oOO-'-.- .. iI} 3.9 8.S,..~.-I 16.~. .~?.1 35.3 129.8
4~._._. 4.800 'DIIftI","fa..tMtDepM7 __,.. Q.~ <l.0 ~:S. ...,../2..5 15.8 _..?4.?...., M.4 12B.7
foA lS.lS~!J 1/%" MlI/Iij)IjIby2 1.1 4.0 11.1 19:t 29.a 1~4.2
""0- 1o..B.78~". 5/6- Mul/fWbyM 4.~."." ,- 13.6 23.6 _~.1~.~-
au t. Mli/tlpl'1)y4 ,......__. .. 5.,6, 1~.8 110.0
'2- 12.750 M14" Multip~1)y5 8.~_.... .19.Q.,~~
M~-i.icioo'''"'. 196
IMPO~tANT N~ n.'loble I~ rot ~matlon pl""._ ~~~'Con!JU1I UL F1~ R~8Isll'l'l~. D~ltIryaSTI ~ & Ajlpll(:8llon (lIM~ i;;'''.P<CIflC In!\lllll8tlon reQllra~';;'; ..d n~hn;~~~-
2
www.sti(;r~$fop.eom << Toll FI'\l(l 80~992,llBO
I~J Spacified Technologies. Inc.
05/05/2005 10:21
2335747
ThIJS all systems have been designed to
provide T Ratings capable of matching the
rating of the wall or floor assembly (where
possible) when tested without penetrants.
5. SP-=CIFICATIONS
See page 1.
6. INS1'AUAlION INstRUCI10NS
General; Areas to be protected must be clean
and free of oil, loose dirt. rust or scale. Instal-
lation temperatures must be between 35QF
and 100.F (1.70Cto 37.8"Cl. Allow product to
dry a minimum of 24 hours before exposure
to moisturt;l.
System Selection: Selection of an appropriate
firestop system design Is critical to the fire
protection prooess, Space limitations pre-
clude highly detailed information pertaining to
individual application syStems. Please consult
the STI Product & Application Guide as well
as the UL@ Fire Resistance DirectOry for ad"
ditionallnformatlon.
Forming: Some installations may require
forming as either an integral part of the sys-
tem or as an option to facilitate Installation. In
syStems where formin9 is required, mineral
wool batts (1-1/2" to 3 nominal thickness. 4
Ib.lcu. ft. density) are recommended, Some
gypsum wallboard systems utilize fiberglass.
Cut forming meterial over-slzEl to allow for tight
packing. Position forming material to allow for
the proper depth of fill meltarial.
Fill Material: SpecSeal@ Series SSS Sealant
may be Installed by caulking using a standard
caulking ~un or from bulk containers using a
bulk loadlf1g caulk ~un, or by m~nually troWel-
Ing using a mason s trower or putty knife. If
tile sealant tends to pull back from a surface.
clean the surface with a damp rag or sponge
Sind reapply. Work sealant into all arsas exer-
cising cere to eliminate voids or seams. The
surface of the sealant can be smoothed using
a putty knife dipped in water. Adding water to
the sealant Itself is not recommended. Seal-
ant (when dry) may be sanded and painted
using most non-solvent based paints. In gyp-
sum wallboard penetrations, crown searant
1/4" (6.35 mm) from penetrant to wallboard
surface at a point approximately 1/2" (12.7
mml or more from opening,
J RASMUSSEN
PAGE 04/09
Fid- 3= ELI!CTRICAL. DATA OR c:oMMUNlCAnotlS PENETRATIONS -
itA.TED oYPSlJM WALLBOARD ASSEMBLIES
...
8.- r~
(eolh~
I\-~)P"'"
Wll-
~btf
.
Gyl*JIIl
~MfI1b1y
UI- SYSTEM W.L-2093
FRs5ng: 1 or2 Hr - r RatIng: 1. 1-112 Hr
2" Rigid PYC, ENMT.
CKOpllcal Rber Racewlil')
1-1/4" PVDF Optical Fiber Raceway:
Sealarll Depth: 516' lAAtI'llf4" Crown
I fig. 41 BECl'RlCAL PENETRATIONS .
CONCRE1'EJMASONRY FLOORS & WALLS
UI- SYSTEM W-L-3076
F Ratlna; 1 or 2 Hr - T Rmmg: 0 hr
U'p 104" Cable Bundle
CenteJ'l!ld In 4 - 112'" opening
Sealant Depth: 518" v.11h 1/4" Crown
l
StwI
SI_
8alllgnt
"
eon""""
FIo<>r
UL SYSTEM C-AJ.3154
F RatIng: 1, 2, 3 & 4 Hr . T R.3tlng: O. 112. & 2 3/4 Hr
Or;nlonal Slee.oe-FVC or Steel
El~ctrIcaI. TelephonS or D3lll CableS
Annulus: 0" to Z'
Sealant Depth: 112"
Foming Mater1als: Nom II pef Mineral Wool
Sealam Depth: 112" for 1, 2, 3 Hr; 3/4" for <1 Hr
Fig" 5: BARE & INSULATED METALLIC PIPE PENETRATIONS. RATED GYPSUM WAllBOARD ASSEMBLIES
UL SYSTEM C-A.l-8008
F Rallng: 31-1r . T Rating: 0 Hr
Aluminum or Copper Bus Ducl 5,000 Amp
Steel CcM3r Plate
Sealant Depth: 112"
Fonnlng Mater1~Is: Nom 4 p::r Mlnellll Wed
Tlghtly Pa~ 108 depth of 1-117.'
~I)I
UL SYSTEM W-L-1049
F RaUna: 1 t.:2 hr . T RatinQ: 0 Iv
$lee! or Iron Pipe: 24". COpper I'tps: ll"
Annulue: Point COn1aCl1O 1-314'
SR.B1snt Dsplh: 518" WItt! 318" Cl1Jwn
~J Specified Technologies, Inc.
UL SYSTEM W.L-5014
F RatIng; 1 & 2 Hr' T RatIng; 1 hr
Steel or Iron Pipe: 12". CooperPIpc: 4"
ln~laIed wllh 2' Thiel< ~Iber Glass
or Mlner.31 Wool Pipe h"lSU\~lon
Annulus: f1' 10 1-1/4"
Sealant Depth: SIB' with 3Jg' Crow1
UL SYSTEM W.L.5051
F Ratlng: 1 & 2Hr - T R0llng: 1.1/2 Hr
SleeI or Iron Pipe: 4", Capper P1,:.e: 4"
Foam GI;$S F>lpe Insulalion: Z'Tt1Ick
12' WldA 0.01 (J' ThiCk M6llI1 Jacket VvTappo(l Around
1l1l3ulEllicn and $ecul13d with Metlll Banding ElS Sh(lWl1
A~nulus: a" to 3IfJ'
Sealant Depth: 51fj
www.atilirQ5top.com.ToIIFree800-992.1180
3
05/05/2005 10:21
2336747
Smoke Sealing: In some applications including nrestop col-
lars. SpecSeal@ Series SSS Sealant Is recommended as a
smoke seal. It is suggested in these applications that the
sealant be applied to both sides of wails. In floor applica-
tions. a sealing bead is suggested top and bottom.
Cover Plate: In some designs a galvanized steel cover plate
(26geuge) may be used to upgrade the fire resistance rating
to 4 hours. Consult STI Produot and Application Guide for.
dimensional and fastening requirements.
LIMITATIONS: This product Is water-based and cures through
the evaporeltion of water. Low temperatures, high humidity.
the use of non-porous or Impermeable backing materials,
cover plates or coatings may retard the drying process. Do
not paint or seal in any way that prevents contact with air
until sealant has dried through completely. This product has
been designed to be safe with plastics and has been used
extensively and successfully with a variety of different types of
plastic pipes, tubes. and plamic cable insulations. Variations
in these materials however, make It impossible to guarantee
compatibility. STI strongly recommends that the user oonsult
with the manufelcturer of the pipe. tubing, or cable in ques-
tion regarding any known sensitivities or potential restrictions
before applying this product.
7. MAINTENANCI!
Inspection: Installations should be inspected periodically for
TABLE D: ORDERING INFORMATION
CAT. NO. DeSCRIPTION
SSS100 10.1 oz- Tube (300 ml) 18.2 cU.in.
SSS129 29 oz. Tube (85~ ml) 52 cu. in.
S8S120 20 oz.. Sausage (592 ml) 36 cu. in.
888102 ;2 Gal. Pail (7.6 liters) 462 cu,ln.
888105 5 Gal. Pail (19.0 liters) 1.155 cuJn.
Add/tIomII SpecSeeI hocfut:is-
SSPFIrMtDp ~
Available both in bar fOnT! and In p~ds. putty provides eF.lllY retrofit
forthrough-penetl1i!tions and economical proteetion 10r electrical
boxes.
SSB P'IrH1DP PIlIcwvs
Durable. monolithic pillOWS for inatallations requiring quiCk and
€21sy retroflttlng_ systems designed for pipos. cables f,lnd ceble
tray in ~lIlypes of conRtruc:tion I
J RASMUSSEN
PAGE 05/09
subsequent damage. Any damage should be repaired using
SpecSeal@ products per the original e1pproved design.
Retrofit: When adding or removing penetrants. care should
be taken to minimize damage to the seal. Reseal using
SpecSeal<!!;1 produCts per the approved design. NOTE: New
penetrants of a different nature than the original design may
require a totally new firestop design or t;lxtensive modifica-
tions to the existing design. Reseal all openings as per the
requirements of the modified design.
8. TI!CHNICAL SERVICE
Specified Technologies Inc. proVides toll free technical sup-
port to assist in product selection and appropriate installation
design. UL Systems, Material Safety Diilta Sheets and other
technical Information Is available at the Technical LIbrary at
www.stlflrestop.com.
9.. PRECAUTIONARY INFORMATION
Consult Material Safety Data Sheet for additional Information
on the safe handling and disposal of this material. Wash ar-
eas 01 skin contact with soap and water. Avoid contaot with
eyes. SEALANT IS CONDUCTIVE UNTIL DRY.
10. AVAILABILITY
SpecSeal@ Series SSS Sealant is available from authori;ted
STI distributors. Consult 'factory for the names and locations
of the nearest sales representatives or distributors, Available
packages and additional SpecSeel@ Product$ are listed be-
low.
IntumM(;eot wrap Sbtps
ThreE! grades of intUfTl6scenl wrap strips provide an unmatcned
combination of flexibility, economy, and expansion (up to 30X).
Systems for plasrlc pipes inCluding FR Polypropylene up ro 8'
rmde sizel
MCIId8d I'IMstDp eon.m
Easy to install, economical "rotectlon for ABS and PVC pipes
(both solid end foam core) as well as CPVC. PVDF. end ~RPP.
Callers available up to 6" trade size,
CITY OF NEW YORK MEA 28-92M
Impo",Int Nclb!!: o\Jllll9telT1'l"llI. IIlchnbll ill!oM1Slicln. E>">:l """"mmorn3llons contained ~n "'" besed
"fXl" It!~ beI1ll'1ed to 00 11ll"b1n.1:xJt Ih~ BCCUI9::)I emd onm~ IMIllOi IS not g11~"'n!ot>d.
WARRANTY: Specified T,:",:"oIO?I~e Inc. manur"",u",. It. ~od8ln e m9f1l1E'rtn bo f",,~ oT delects,
Should env Clala",' "!:!cur In ~s goQas (wllhln nno )'CI~r). SpeclAed T<l~hnnlo9i"" Inc.. upon prom!)'
noijllcellon. will "t k. "pllon. exchan~ or """,Ir rhe goods or '~un(llhn pun::1l8!l$ prlce
Liml1allol1ll and F.i<c1U!llons: THIS wAAIlAN1YIS IN LIEU OF ALL OTf-lI;R REPRJ;SENTATIONS ExPRF.S-.<;ED
OR IMPIJED (INCL!JOlNG THE IM~I ,lED W^RAANTIES OF MERCH^NT/lBILITY OR FITNESS .OR USE)
AN[)lINOER NO CIRCUM$TANCf.~ SI"f\LL SPECIFIED l'ECt-lNOLOGIES INC. Be I'lIi.$PONSIBLE fOR
^NY INCIDENTAL OR eONSF.:QUENllAL PROPEm DAMf.GE OR LOSSES. PRIOR TO USE. TI'IE lJ5ER
SI-I^LL DETERMINE THE SUITNllLllY OF THE PRODUCT FOR ITS INTEMOEO USE. ^NO THE U$F..R
As."lUMeS ALL RISKS AND LIAB1LIlY FOR SU9SEQUF.NT USE.
~D ~I.atemem or racoml11ll<1cl:ltbn n~ contalll!ld ~n .1-..11 h>lvs env IOrce 01 ~ 1I~ " >In E1Qreemefll
/IIClI"IecI by o"lm", of ""ikT;on:l rnsnufaeMa~ . .
MADE IN THE USA - COPYRIG1"IT@ 2004. SPECIFIED rI;.CHNOLOGIES, INC,
4
www.~Il_Pop.ClOIt1 . Toll, ~Fll9 800-992.1180
II Specified
'-STI Technologies
· Inc.
200 Evans Way. somerville. NJ 08676
Phone; (000) 992-1180 . Fax: (90B) 526.9623
STI on \tie WEB: 'MWJ.sllflrestop.oom
\~] SpecifIed TechnologiC', Inc.
05/05/2005 10:21
2335747
J RASMUSSEN
PAGE 05/09
SIiL~-2tN)'llllll~
PRODUCT DATA SHEET
Firestop
Collars
ReprodtJced from Electronic Media
1. PRODUCT DESCRIP'fION
The SpecSea/(ij') Firestop Collar Is a factory..rnanufadlJred device designed to protect plastic pipes
penetrating fire-rated walls and floors. UtIlizing a heavy gauge galVanized metal roJIar to house a
molded intumescent insert. the SpecSeal@Collarisspecificallyslzedloflt 1-112". 2", 3",4", and 6"
trade sized pipes.
This product utilizes STI's pa~nted two-stage intUmescent technology, provlding a very responsive
and highly dlrectionallzedexpansion. Expansion is extremelyfast, providing quick closure for burning
combustible pipes.
When exposed to temperatures In excess of250OF (121" e), the SpecSea/@Collar'smolded Insert
begins to expand (Intumesce) rapidly to form a dense. highly insulative char. Its free expansion
ranges m:rn 16-24 times original (pre-expanded) volume. expansion contlooes up to 1,??oo F.
2- APPLICATIONS
specSeai!B) Collars are used to protedavarietyofplastic pipes including PVC. PVC Foam Core (ccPVC). CPVC,ABS,ABS Foam
Core (ccABS). and FR Polypropylene In both vented ~WV) and closed (eIedrlcal conduit and water supply) installatiOns.
specSea~ Collars are suitable 1br use in all oommon form$ of oonstruc.1lon including con<:rete floors, conaete OJer steel deck,
conO'ete walls. concrete block walls. gypsum board walls. and wood floor assemblies.
SpecSeal@ Collars are used alone or in combination, with other SpecSeal@ producls to protect a wide variety of nonmetallic pipe
penetrations either irdlvldually or in combination wilh other typeS of penetrants.
3. PHYSICAL PROPERIlES
See Table A This material is exI18meIy stable. Long tem'I aging studies indicate no signtflcant loss of physical properties nor
significant change in expansion properties after elevated temperat1.re. humidity, and immersion testing. Consult factory for
addlliohal infon'nalicn.
4. PERFORMANCE
SpecSea~ Collars are the basis for systems that meet the exacting aiteria of ASTh1 EB14 (UL 1479). Systems have been tested
for all common forms of construction and most common penetmn1s wiIh mtings up to three hours.
STl designed firestop systems are ooglneered to maximize the fire resistance of the seal by not only sealing o1fthe spread of1ire
and hot gasses but also by minimizing the amount of heat conducted through the assembly. Thus all systems have been designed
to provide T RatIngs capable of matching the rating of the wan or floor assembly (where possible). Consult faclory tbr Infonnatlon
not available in UL Fire Resistance Directory as of this printing.
NOnce: The use of this product may be tegV#at8d by regiort81 or local codes. CONSULT THE LOCAf..AUTHORITYHAVING JURISDlCT1ON.
5. SPECIFICATIONS
The firestop system shall be a factory assembled flrestop collar utilizing a molded
two-stage, flexible Intumescent insert. The intumescent insert shall provide a
minimum of 15X free expansion aod shall contain no water soluble expansion
ingredients. The specified material shall be approved for a wide range of appli-
cations includIng PVC. CPVC. ABS, ABS Foam Core, and FRPP pipes when
used by itself or in combination with other products from the same manufac-
turer- The collar shall be UL Classified and/or FM Systems Approved and
tested to the requirements of ASTM E814 (UL 1479).
SPECIFIED DMSIONS
OIV. 7 07840 Through-Penetration Firestopping
OW. 13 13900 Special Construction Fire Suppression & Supervisory
Systems
DIV. 15 15250 MechanicallnsuJation - Rre ProtaCtton
ON. 16 16050 Basic Electrical Materials & Methods
~
llUll
lIIROUGfl-PENETRATlON
F1RatOll DEVICE CLAS$IFlEll BY
UNOERWRrTERSLABOAATORIES INC. i
SEE Ul. FIRE. RESISTANQ; DIRECTORY
FEATURES
.. Rapid Expansion: Closes
off burning penetrants faster.
. High VoIulI't8 Char.
Expands over 20 times!
.. WJdarI.Re8istant: No
soIubte or hygroscopic
ingredients.
. economical: Factory
assembly ' reduces field labor!
.. Easy Installation: No
guess work.
. ApprovRd for a wide variety
of pipes and constructions.
For the latest Product and System Information, Call
STrS FACTS"ON~DEMAND autGmated infonnation attendant
system by dialing toll~frM (888)526-68001
STI Product tll'tA 9Nllll . Fl"'., !;oll_
FOO-5013 121~1I
Pa~8 1 of 4
6. INSTALLATION
GENERAL: The instaRation of1his product requires the app6cation of a smoke seal utilizing SpecSeal@ Serles SSS Sealant and
suitable mechanIcal fasteners for attachment to the floor or waR surface. Sealant and flOOf or wall attachment hardware must be
purchased separately. Any fasteners required to dose the conar around the pipe Itself are Included in the collar package.
SYSTEM SELECTION: Proper methods and materlals are critical to flrestopping. A number of methods have been developed to
suit a wide vartely ofllrestopping applications. Tables B and C have been provjded to assist in determining rI systems suitable for
various applications. Furthermore, many installations have been llIustrated throughout this da1a sheet and nr:NJ ~s are
continually being tesled. For more information consult your local disb1butor, sales rep. or call STI toll free at (800) 992-1180.
SMOKE SEALING: Smoke seaRng is a vital s1ap in the fires10pplng process. , Sil1(:e proper smoke seal design wlII vary from one
type of construction to another, STI has elected to require a separate seating step. A separate seal provIdeS for abnormalities in
floor or wall surfaces (such as blow<luts in core drilled holes), variations in annular space, and preven1s the passage of smoke
produced by deterioration of the pipe Itself within the wall or 1I00r cavlty. This seal in floor applications, also seals against water
leakage into the floor cavtty in plumbing or mechanical installations. For additional information on this topic, request "Firestopping
Plastic Pipes," SpecSeal@Technology Update.
Smoke seals should be installed at the top and bottom surfaces offloor/ceifing assemblies. In solid concrete floors, a single seal
may be installed at the ~er surface. It is strongly recommended however, thetan additional seal be caulked at the top side to seal
against smoke generated within the floor cavity ilself. Smoke seals are required at both sides ofwood floor assemblies and hollow
wall cavffies. .
Apply sealant to a clean surface, free of dirt, oil, rust. or scale. Caulk annulus shut using a nominal 318" bead. Sealant may be
smoothed out or the collar may be set dimclly into the wet sealant.
NOTE: Collars Installed around pipes poured directly Into SpecSeal@ Mortar do not: require fhls sealing step.
FASTENERS: IWmys use the COITect
typeoftastener. ThefasteJ1ert)'pesused T8ble C. APPLICATION .NFORMATION
A1in IPfa~shoustingldabere steelshown(le ind Ta~. DESCRIPI10II pfE SIZE ATTACtIMIOO' ANNlUR ilL SYS. NO, HOURLY FIG.
;;10"" '''' '" a or..........c FLOORIWALL CONSTRUCT. HARDWARE" SPACE RAnMG
fasteners are unsuitable and should not
be used). 11/4- or 1112"fenderwasher.;
are used in conjundion with aD wall orfloor
fasteners. AD fasteners should be Ins1aUed
as per the recommendations of the
manufactLlrer.
CONCRETE: Expanding wedge type
anchotS(1/4.x1314'~arerecommended.
Powder activated fasteners may be used GYJIIlum Wanbolll'd
at the discretion of the installer and are PVC. CF'VC.ABS, FRPP.PVDF
subject to the recommendations of the PVC. CPVC. FR PP, ^9S
fastener I1'I3nufaclurer. Wood Floor Dm"', WlBto, Vent Slack
GYPSUM WALLBOARD: Toggle bol1sor PVC.ABS
moWy-type expandlng anchors are suitable Wood ROCII' Slngllt Collar
for collar attachment. PVC. CI'VC
GYPSUM BOARD-WOOD FLOOR WoocI Floor DolIbltl Collar
FLOORICEILlNGASSEMBLIES: Toggle pve. CPl/C
bolls am suggested for gypsum wallboard
ceiling attachment. Collars mounted
internally and fastened to wood may use
standard #8 x 112" round head wood
SCl'eW$ for attachment.
06/05/2005 10:21
2335747
'.'
Table A~ PHYSICAL PROPERTIES
1WlI11lIb1lt 8m
SheD ConrltI'\ldocl
11'llurI1BlICll11..,t
ElqllInBton B8ghI
1.5" ttru 8"
22 G1;I~ Gal. SIeeI
Molded one pleoe,
250" F (1&1 slage)
~F(2nd_)
1610 24x (1l9U~nsian)
"130. F.
No Change (6O"C\"
No Cl\angll (6O"C. 98% R.H.r
\/ollmle EJIpmllIon
In&NIce'tomp.
Oven AgIng
Hunlkllly Expoture
. EvaWfiOn rlp~~lI!ldlD1al~
PeRe 2 or .4
J RASMUSSEN
PAGE 07/09
Tab.. D: COLLAR DIMENSIONS
-
Mo!
~lAl
~I~I
The following dlmel1!1!ons are provldlld for in~\allation
pmpcsa~ only. All dlmllnsicns have be(!n roundad up
10 {na next 1110th In.
"NOTE: (sea Below) The 'A' dlmtlnSlon for SSC800
I'lIpreseFl1s the max. width of collar allabs that are
1SOe oJlllOsed from each olhar.
-
-c-
CAT NO: SSC151 SSC202 SSC301 SSC400 SSC600
Trade SI%o 1~1/1" 2'" 3" 4" S"
A 4.2" 4.5" 5.SM 7.1" 11.2....
B 2.8" 3.2" 4.5" 6.2" 8.3"
C 1.5" 1.5" 2" 2" 4"
Com;reIIl Floor
PVC, CPVC. ASS, PVDF
FRPf'
PVC, CPVC, FR pp, ASS
S:4"
s:4"
ft
~112"
SII2"
s112"
('AI.2038
CAJ.2045
CAJ-2089
:;:3
!:2
!:3
J,4
3,4
'3
CClm;m.. or Block Wall
P\lC, CPVC,ABS, P\IDF
FRF'P
PVC, C?VC. FR PF', ABS
CAJ.;zo3B
CAJ.2045
CAJ.2089
:>3
$2
~3
5.6
5,6
5
$4"
:$:oiI"
6"
!:112:'
~112."
$112"
:!!::4"
6" '
201'3
2<<3
WL-2029
Wl-2074
~2
s:2
7
7
$112"
$112"
$4"
4
$1/'t' Fc.2034, ~5
~4"
3
$112"
Fc.2020
:;;2
8
S4"
3&4
s1/2"
F~021
~2
9
. AllACHMENT HARDWARE CODE:
(Fender washer!! ere recommended and often requhed)
1 " Concrete wedge ancl!ln, 2 c Sll3e1 molly.type f85teJlBl'S
S " 31'16' Toggle bolts. 4 " lIS X 112" 1'llUIld head wtlOd SCl'llWS.
NOTE: PVC iii ABS IIRIlppnJWd for solid or c:ellulllt cant piping up 10 four Inch tI<Ido ,IZll,
STI P",d_ Dma SlI&et. FI-top Cui"'...
FOD.,,01~ 1,,/1lQ
06/05/2005 10:21
J RASMUSSEN
2335747
Fig 1
MllllCllllY
And'lOl'
Fig 3
P188t1c;
PfP8
SlIeItlnl Ullllzgd
AS Smoka SlIaI
~
.0
of.
4
<l
of
<1
..
t
J lrrbmtaC8nt
InsOrt
st\tB1i=
Shill!
INSTALLING INTUMESCENT INSERT'
INSTALLATION PROCEDURE:
1.Apply smoke seal (see above).
2. To install collar around pipe: Flex intumescent Insert. followed by the outer steel
shen 8roood pIpe (See Fig- 1). Close s1eeI sheH around insert and fasten by
crimping tab oIoswe for SSC151. 202. and 301 models (see Fig. 2), or by bolting
shell together using supplied fasteners (SSC400 & 600 models). Snug fasteners
sufficiently to allow collar to slide,
3. Slide collar to wall or floor surfaoo and mark anchor holes for drilBng.
4. Drill holes and install fasteners as per the requirements of the fastener
manufacll.Jrer. Place 1 114" fender washers of the appropriate c6ameter r:Ne't
fastener at collar mounting tabs and tighten anchors fully.
5. Recheck and tighten shell bolts ftlllyto complete instanation.
7. MAINTENANCE
INSPECTION: InstBnationsshould be Inspected perioclically for subsequent damage.
Any damage should be repaired using SpecSeai03) products per the original approved
design.
RElROFIT; When adding orremovlng penetrants, care should be l:eken to minimize
damage to the seal. Re~al using SpecSea~ produdS per the approved design.
NOTE: New penetrants of a different nature than the original design may require a
totally new firestop design or extensive modifications to the exlsltng design. Reseal all
openings as per the requirements of the new design.
B. TECHNICAL SERVICE
Specified Technologies 100, provides toll free ted1nical support to assist in produd
selection and appropriate InstallatJJn design. Design System Dra\Nings suitable for
submltlal or spec:lficationpurposes are available on request.
9. PRECAUTIONARY INFORMATION
Consult Material Safety Data Sheet for additional information on the safe handling and
disposal of this matertal. Wash areas of skin contact with soap and water. Avoid
contact wltt1 eyes.
F112; SIC151. 202 & 301 CRIMP CL08URIE & MOUNTING
PAGE 08/09
Fig 4
4A
of A
Meoonry
An~
S~I.
SSC301 COliill'
Fi9.5
SpecS8lI11l!I
.. .. Collar
Conc:ilWhI or
BIodc WIlli
.. ..
FIg 6
...
SpeeS8llIa.
SSC301 Collar
of .
CoI1I;r818 elf
Block waI
PQge 3 or 4
$" ProdlJC'! Of'l. Shftet .. F'....tcrp Celllllllnl-
3. Crimp tabs closed using pRem. 4. Fasten 10 wall or floor.
FOO.~OlJ 1219il
1. Wrap collar around pipe.
2. Press tab into slot.
05/05/2005 10:21
2335747
Flg7
~4
....
SlIGI,.,t UU~
M ~$MII
Taggle Belt
I~ CoII8r
I
Fig 9
PlyWOod
SUbftDar
GypsumJ
WaIltlO8rC:l
!!leallUlt Utlllzed
NJ SITltlkB Seal
Toggle Bolt
J RASMUSSEN
PAGE 09/09
10. AVAILABILITY
SpeoSear Rreslop COIIam are available from authoriZed 511 distr\blJtOIS natio,r1Wlde.
Consult f\:lCtOIY for the names and locations of the nearest sales represenlBtiVeS or
dIstributOrS. Available packageS and additional SpecSeaf'b ProductS are !\sled in Table D.
Table D: ORDERING INFORMAnON
Cat. Mo.
SSC151
M'DMe Oellcrlptlon
Firer.lop Collar Fits 1-112" Trade size
pipes. Utilizes crimp closure.
SSC202. Firestop Conar Fits 2ft Trade si%a pipes.
Utilizes crimp closure.
SSC:;101 Firestop coller FilS~" Trade sl<:e pipes.
Ubllzes crimp closure.
SSC400 Flrestop Collar Fits 4" Trade size pipes.
Utilizes bolt closure, bolls InclUded.
SSC600 Flrestop CoII{lr FIts e" Trade size piper..
Utlllze$ bolt closure, br;l1ts Included.
Additional SpecSeal Products...
SMte9 SSS Sealant The indUsl!y'll most veraatlle sealant provides the ftrestcppplng
solution!;! for a wide range of combUstlble and ntlneombulltible
,appllcatJon$. Water--beMd Intumascent sealant elCpands up to 6xI
Serles LC Sealant An economical latex fln;!stoP sealant for noncombustible
applications. NOr)otll;llogenate<l. easy clean up, flexible. water-
I'llSlst9ntl
SSP Flreatop PuttY Available both ill barform and In pads. putty pmvlde$ easy retrofit
for through-penetratiollS and ecQfIOITIiClilI protection for eleetrlcal
boxes.
sse f'1res10p PIlIOW& DUl'able. monolithic: pllloY/5 fOr inslallirtiOns requiring quick and eer.y
retrafilllng. SyS10ms designed for pipes I cables ~ncl cable tray In
an types of cona'InJc:lkml
FlntBlep Mortar LlghlWalght, versatile and economical! The bast chOic& for large
or complex Insmllations.
Pensl" Silicones SealardS and 1bam forthrough~netfstkms and constructionJointa.
UnexceDed aging characteristiCS and flexlbnlty.
Intume¢ Wr8p Strfps 1\vo grodllG of intumescent WI':!Ip sttips provide an unmatched
oombinatlon of flexibility, eoonomy, and expanslOl1 (up to 30X).
Systems for plasflc pipes including FR polypropylene up to aft trade
slzel
Elastomer1C Joint Seats New economical produr;ta for se~lling constllletion )oin1S. Chooaa
caulk or spray applied products testad to VL.2079.
CITY OF NEW YORK MEA 307-92M
Impoltant Nallco: N1 ststal"lllll11!t, lechnicallntcnnation. 11m! recOmmendallot'l$ contained herein
are baaed upOn lesdng belloved III 17$ l'$Ileb4e. but 1M accuracy !!1M compl0leneBll thamof 19 IICt
gl/al8ntaed.
WARRANTY'. Specllled 1lrlIIIol~ 'PIC. IT18l'I\If<IClU191l Jlll goodllln II M3IlI1Sr In be Il'ee of detllets.
Should lIny defect occur In lis gootl"!1 (wllhln one year). Specllled Tee/lnologloo Ine., upon prompt
notitteHllon. will 1lI: il!I optlcn, ~ehBnQs or ~Ir!he good!! Dr refurld lh9 purchase price.
Umlllltlone and Exclut:lolltl: THIS WARRANTY IS IN UEU OF ALL OlHER
REPf/.ESENTATIONS EXPRESSED OR IMPUED (1NCWOING THE: IMPWED WARRANTIES OF
MERCHANT~ILITY OR F"ITNESS FOR USE) AND UNDeR NO CIRCUMSTANCES SHALL
SPECIFIED TECHNOLOGIES INC. BE RESPONSIBl.E. FOR ANY INCIDENTAl. OR
CONSEQUENTIAL PROPEFtlV DAMAGE OR LOSSES. PRIOR TO USE. neE uSER SHAll.
DETERMINE 1l1E aUITA8'UTY OF THe: PROC\JCT FOR ITS INTENDED USE.. AND TJ--IE USE:R
ASSUMES ALL RISKS AND I.IA61LITY FOR SUBSEQUENT USE.
NO stBtamentorl'8COmmefldlllllon notCOt'rl~lned he~ir1 sM11 00'19 anyfm:e oreffocl unleSS in Illn
Bg~t signed by ofIIcsl'!l ofllellgr and mBn~l'llr.
MADE IN THE USA - COPYJtIGHT e 2tlOO SPECIFIED TECMNOLOGlES, INC.
~ Specified
STI ~~~ologies
200 Evans Way A Somerville, NJ 08876
PhOne: (800) 992-1180 A FalC: (908) 526-9623
Facts.on-Demand: (888) 526-6800
STI on the WEB: www.stJfirestop.COOI
pftg.. <I Df 4
STI Pmduef DAIA SI1RoI . ",",,,top Collars
FQll.!!013 121M