Loading...
HomeMy WebLinkAbout0119318-Plumbing e OSHKOSH ON THE WATER Job Address 149W24THAVE Contractor J RASMUSSEN PLUMBING INC Bathtub Whirlpool Lavatory Toilet Res. Sink Bar Sink Water Heater Site Drain Roof Drain Misc. Fixtures Use/Nature of Work Valuation Issued By CITY OF OSHKOSH No 119318 PLUMBING PERMIT. APPLICATION AND RECORD Owner 149 W 24TH AVENUE LLC Create Date 05/04/2006 Category 410- Residential-Interior Plan WaterSoftner Wait St. Shamp Sink - Coffee Maker Local Waste Ice Chest FlrlWst Sink Int Grease Trap Clothes Wshr Exam Sink Catch Basin - Ext Grease Trap - Bidet Sculry Sink Wash Ftn RPZ Valve Beer Tap Hand Sink Urinal Eye Wash Statn Lab Sink Plaster Sink Standp Rec Wtr Sewer Mtrs Sterilizer Surgeons Sink Ice Maker Deduct Meters Dip Well F Prep Sink Gar Drain Wtr Usage Mtrs Drink Ftn Serv Sink Soda Disp 1 Shower Floor Drain 1 LndryTray 1 Disposal Dishwasher Sump Pump Classrm Sink Breakrm Sink Ejector/Grind NEW BATHROOM ADDITION IN APT 101 "DEBIT ACCT Size Material Type # Conn. Type Sanitary Sewer Storm Sewer Water Service Parcelld # 1411450100 $3.000.00 $0.00 $21.00 0 Permit Voided I Permit Fees Plan Approval Date 05/04/2006 In the performance of this work, I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which It is not a party, if you perfonn the work described in this pennit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Address 1914 GREENBRIAR TRL Date AgenUOwner OSHKOSH WI 54904 - 0000 Telephone Number 920-233-6747 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not perfonmed within two business days from the time the project is ready. :::. ,05/05/2005 ::: . 10:21 2335747 J RASMUSSEN PAGE 01/09 Rasmussen plumbing, Inc. Jeff Rasmussen Master Plumber #223251 1914 GreeJlbriar Trail Oshkosh, WI 54904-8887 = -~ lIIIOI;:: ~ Phone: (920) 233-6747 Fax: (920) 231-1289 E...rnail: rastn\\ss@charter.net. DATE: b- S - ~ l Cn..~ ofl'ax R;:clVed Req"..t.d:l TIME: /6 ~Jo 1<'7'- _ _ ..-------LJ YES_ ~ NO. OF PAGES (Including Cover poge): _3 TO~ t! fvD (~ FROM: 5" :!:a - 3" J ~ I\o.-'-'-.l J ---- f lL a;... " - MESSAGE: ~07"/;'~--~'~ ~~ ...,.'D"~.'.. .. '.. ..~.~. ..... ............ ....... _ ..___m.'~,_"""W"~ ','_' -__",,~"';''''''':-''";:;2'''''':,;'~';''.~:'~~'~' ,',"', ,::,;".:;:~:,-:~:'~0:,,":'~'~,>',"~:''':;:':; :;,'\-_::';':'~ "LJ....",..,._-J;d.. ......---........... . .~.........~ ,_( _ ',_ _ ",__...;. :.7""- ',,'- d.t:.t L It r'."'- A# ,1--1 ~~ '':'~'''-' "-:~\;:1~ 4ff /lJ l ~ r1 - ---'~ ~-- 05/05/2005 10:21 2335747 J RASMUSSEN PAGE 02/09 ~]S~~f~';~~9~~~A SHEET ~!IIUllli Series SSS Intumescent Sealant I~~~~I ~F1Ll' WID OIl CAvrrY IlAlERllU CI.~At",1I!11IY lIIDERI'IRII1i"" LollOllO_lea IIlC,. fCIIl uftll , ilL IN 1l111911...._!'IltA'IlON , Y FTM:e8TOPJl"f!fitlMI!l. 1111 BFe ... FmI! RESISTANCE DIRE<mJRY ~ ..ur.... CLAS!Il"ED P.... WIll, "" ""VITY ....TallolI.8 ~ fOR"'EIll_-l'ENrnUmllOl~all8- n IMIJBCB. 9EEULllIIlIIcftlIYOP~ C T CERlIFlED FOR IW'AfJA ollll IA. _ III!S181J>.NCE DIIlECToPV ~ APPIIOVElI FEATURES . Water.BeAod for easy Installation. cleanup, and dlspo$<ll. . Two-Suge Intum.-cence features extremely fast and drrectlonallzed expansion. . Endothennlc FII"r9 absorb heat & relerjlse water. .. High Sollde Pormula means no shrinkage! . Sandable & Palntable (when dry) ... Wstar-Reslstant: Will not re-emulslfy when dry! ... Sate: Low VOCs, No Solvents . Red Color for easy Identification and Inspection. .. MultI VI~lty Grade meanS excellent caulking propertie!'; along with high bllild capabilities. . ~lIent Smoke Seal I~J Spllclfled Technologies, Inc, 1. PRODUCT DESCRIPTION SpecSeal@SerieS SSS Sealant Is a latex based, high solidsfirestop compound. This material, when properly Installed, will effectively seal penetration openings ageinst the spread of fire, smoke, toxic gasses and water. SpecSeal<ID Series SSS Sealant features STI's patented and proprietary two.stage intumescent technology. When exposed to high temperatures or flre. this material expands aggressively in a highly directlonelized fashion to quickly close off voids left by the burning or melting of combustible materi;:lls. SpecSeal@SeriesSSSSealant'sunique multi-viscosity formula yields a singre grade that has excellent caulking properties as well as high build properties on vertical or overhead surfaces, This single grade may be pumped, caulked (standard cartridge or bulk loaded), knifed or troweled. In addition, SpecSeal@ SSS does not contain PCB's or asbestos. SpecSeal@ Series SSS Sealant is storage stable (when stored 61ccording to the manufacturer's recommendations) and will not separate nor shrink when dried. SpecSeal@ Serles SSS Sealant will adhere to all common construction and penetrant materials and contains no solvents making it safe for use with most plastics, 2. APPLICATIONS See Table A for a summary application list. SpecSeal@ Series SSS Sealant is used to seal through-penetrations as well as construction gaps and blank openings, Series SSS has been tested tor use with metallic penetrants up to 30. (762 mm) trade size. This product is also used with other SpecSeal@ Products such as SpecSeal@ Firestop Collars Glnd Wrap Strips. 3. PHYSICAL PROPERTIES See Table B. 4. PERFORMANCE SpecSeal@ Series SSS Sealant Is the basis for systems that meet the exacting criteria of ASTM EB14 (Ul1479) as well as the time-temperature requirements of ASTM E119 (UL263). Systems have been tested foral! common forms of oonstt1.lction and most common penetrants with ratings up to 4 hours. STI firestop systems are designed to maximize the fire resistanoe of the seal by not only sealing off the spre61d offire and hot gasses but arso by minimizing the amount of heat conducted through the assembly, 5. SPECIFICATIONS The firestopplng seslant shall be a one-parI. twl>-stage intumescent latex compound. The sealant when expOSed to high heat or flame shall be capable of expanding a mInimum of 8 times. Range of conlinuing expBnslon shall be from 2300F to >l,OOO.F (1100C to 53S"C), The sealenl: shall be thixotropiC and shall be capable of caulking or troweling onto vertIcal surfaces or overhead. The sealant Shell be UL Classified and/or FM System!; Approved and lestoo to the reQuirements of ASTM F.814 (UL 1479). SPECIFIED DIVISIONS DIV. 7 07840 DIV. 13 13900 DIV. 15 15250 Through-Penetration Firestopplng Special Construction FIre Suppression & Supervisory Systems Meohanlcal Insulation - Fire Protection DIV. 16 16050 BaSic Electrical Materisl$ & Methods STI Product Data She<>t . SllI1116 ssg InlII""",alltlt halaftt . 1'00.5001 001?004 www.Btlflre3!op.c;Qm . Toll Free Boo..m.l' eo 05/05/2005 10:21 2335747 Table A: APPLICATIONS Tested & cla.sllled for 'Ir. Resistance , Metallic: PIpes Inoluding steel, Iron, or copp@r pipe and tubing througl1 all oommon oonstructlons. . Moamet.me Plpos, COftdults &Tublng Including PVC, CF'VC. PVDF. PEX, PEX-AL.PEX. ASS, PB through all common oonstructions. - C.bI8, Cable Tmys & Bus Duct . HVAC DlICtwork . In.ule-tad Pip.. , Multl-Setvlco Penetrations including AC line sets. electrical. telephone, orN service entrance and IntEl riQr penetratIons. . COmpl.... Wood Floor are.topplng p."hga {or electrical, plumbing, HVAC. TV and telephone. Table B; PHYSICAL PROPERnES Product M..... Series SSS Seal~nt Color Red Odor Mild Latcl< D&nslty S.4 Lb/Gal (1.13 kg/L) Solids eoo/. i 2% pH 8.~ &pa",*-, Begins 230'F (l1Q"Cl 1st Stage 350'F (177"C) 2nd Stage ~ R1119 230'Fto >1.000"F (110'C to > 538'C) VoIIIme I!xp8nsIon > 500% Free E:lq:ms!on M_.ln.Servlco 'hIIIp. 120'F (4S"C) Fhllm8 Spread O' Smok~ Development 10' STC Rating 51 voe ConterrtT' 0.1 Bibs/gel (22.0 g/l) . Tosr.,(] IoASTM EM (liL12a) ot 14% surrace O0ll9r~Il" rmodlfl!>d t<Mll for seslent9 91'<1 o~ulk.!t) "A..<;TM D39130 and ErA Federsl Fl<lmrnnoo Malhad 2~ J RASMUSSEN PAGE 03/09 Shown below and on the following page are justa few of the most common app/IcJJtlonS for Specge8I SerlsS SSS Se;IIant. CO/7$ult the Technical Library at WININ.stlflrestDp.com for O~ 200 8V8ilable designs utilizing thIs product. I F1g.1l MIn'ALUC PIPE PENETRAnONS. . CONCRE'TE/MASONRY FLOORS & WALLS .. UL SYSTEM C-AJ-1079 F Rating: 4 Hr . T Raling: 0 Steel or Iron Pipe: 24', CopparPlpe 6' Amulus: !'oint Conl!lCl to 4' . Sealant Depth: 1/2" Forming M$erial: Nom 4 pef Mineral Wool Thickness: 1-112" rer 6' Steel or Iron Pipe S'w 4' Copper or 6' Imn or Slee! Pipe 'f .. UL SYSTEM C-AJ-121'7 F RatIng: 4 Hr ' T Ratlng; 0 Steel or Iron Pipe: 30". Copper Pipe 6' AnnvlLIS: Point Ganlact to T . Sealant Depth: 1 IT Forming Materiel: NO/Yl 4 pcf Mineral Wool l1ghlly ~ to B ~ Depth. Fig. 2: INSUU,TED METALLIC PIPE PENETRATlONS- CONCREtEJMASONRY FLOORS & WALLS UL SYSTEM C-U-SOB7 F Fladng: :il Hr . T Rating: 1 Slrel or Iron Pips: 24" Insulated wlIh 2' THOl< Fiber Glass or Mineral Wool Pipe Il1!'lulllllon Annulus: 112" to 1-112' . Sealant Depth: 1 t:t Forming Materlal: Nom 4 pet Minoral Wool llQhtty Packed 10;;4' Deplh. Table Ci SEALANT REQUIREMENTS IN CUBIC INCHES PER 1/4 INCH OF INSTAUED DEPTH" Pip" SIll:. D..II'l..... of ~,!I_llItI (In.) ... . ... ..." D.D. 1.-' 2.0 3.0 4,,0 11.0 6.0 7,0 8.0 10 12 ~ 2S O,~C ."0:840 O.~ 0.6 1.6 :3.0,:4.1'!. 6,9 9.6 1~.4 19.5 2B.1 ._1~ 1~~.6 1.~_. 1.315 0.1) "0.4 ,."..,~ 2.8 4,EL 6,7 g,:3' ""'1i..:? 1~.3 27..Q,'~:,,,_~~ 132.4_ 1.!5" 1.900 .. ____ 1,1 2.'1 4.2 6.4 B.e 11,9 1B.9 2!-.E1 37,R 132:0 ,,- 2..375 0.7 . ..~.O ~.8 8.0 8.t; 11.5 l.a.!; _ 27.2 37.4. _!a1.5 2.5" 2.875 0.1 1.5 ~.3 5:;;:,:. _~ 10.9 1tl..!L. 26.7 36.9 1~-".L SA 3.500'- 0.7 2.5 ..~.?. 7.2 1Q..2 17.2 25.8 3ftJ 130.;L 3~5.' 4~oOO-'-.- .. iI} 3.9 8.S,..~.-I 16.~. .~?.1 35.3 129.8 4~._._. 4.800 'DIIftI","fa..tMtDepM7 __,.. Q.~ <l.0 ~:S. ...,../2..5 15.8 _..?4.?...., M.4 12B.7 foA lS.lS~!J 1/%" MlI/Iij)IjIby2 1.1 4.0 11.1 19:t 29.a 1~4.2 ""0- 1o..B.78~". 5/6- Mul/fWbyM 4.~."." ,- 13.6 23.6 _~.1~.~- au t. Mli/tlpl'1)y4 ,......__. .. 5.,6, 1~.8 110.0 '2- 12.750 M14" Multip~1)y5 8.~_.... .19.Q.,~~ M~-i.icioo'''"'. 196 IMPO~tANT N~ n.'loble I~ rot ~matlon pl""._ ~~~'Con!JU1I UL F1~ R~8Isll'l'l~. D~ltIryaSTI ~ & Ajlpll(:8llon (lIM~ i;;'''.P<CIflC In!\lllll8tlon reQllra~';;'; ..d n~hn;~~~- 2 www.sti(;r~$fop.eom << Toll FI'\l(l 80~992,llBO I~J Spacified Technologies. Inc. 05/05/2005 10:21 2335747 ThIJS all systems have been designed to provide T Ratings capable of matching the rating of the wall or floor assembly (where possible) when tested without penetrants. 5. SP-=CIFICATIONS See page 1. 6. INS1'AUAlION INstRUCI10NS General; Areas to be protected must be clean and free of oil, loose dirt. rust or scale. Instal- lation temperatures must be between 35QF and 100.F (1.70Cto 37.8"Cl. Allow product to dry a minimum of 24 hours before exposure to moisturt;l. System Selection: Selection of an appropriate firestop system design Is critical to the fire protection prooess, Space limitations pre- clude highly detailed information pertaining to individual application syStems. Please consult the STI Product & Application Guide as well as the UL@ Fire Resistance DirectOry for ad" ditionallnformatlon. Forming: Some installations may require forming as either an integral part of the sys- tem or as an option to facilitate Installation. In syStems where formin9 is required, mineral wool batts (1-1/2" to 3 nominal thickness. 4 Ib.lcu. ft. density) are recommended, Some gypsum wallboard systems utilize fiberglass. Cut forming meterial over-slzEl to allow for tight packing. Position forming material to allow for the proper depth of fill meltarial. Fill Material: SpecSeal@ Series SSS Sealant may be Installed by caulking using a standard caulking ~un or from bulk containers using a bulk loadlf1g caulk ~un, or by m~nually troWel- Ing using a mason s trower or putty knife. If tile sealant tends to pull back from a surface. clean the surface with a damp rag or sponge Sind reapply. Work sealant into all arsas exer- cising cere to eliminate voids or seams. The surface of the sealant can be smoothed using a putty knife dipped in water. Adding water to the sealant Itself is not recommended. Seal- ant (when dry) may be sanded and painted using most non-solvent based paints. In gyp- sum wallboard penetrations, crown searant 1/4" (6.35 mm) from penetrant to wallboard surface at a point approximately 1/2" (12.7 mml or more from opening, J RASMUSSEN PAGE 04/09 Fid- 3= ELI!CTRICAL. DATA OR c:oMMUNlCAnotlS PENETRATIONS - itA.TED oYPSlJM WALLBOARD ASSEMBLIES ... 8.- r~ (eolh~ I\-~)P"'" Wll- ~btf . Gyl*JIIl ~MfI1b1y UI- SYSTEM W.L-2093 FRs5ng: 1 or2 Hr - r RatIng: 1. 1-112 Hr 2" Rigid PYC, ENMT. CKOpllcal Rber Racewlil') 1-1/4" PVDF Optical Fiber Raceway: Sealarll Depth: 516' lAAtI'llf4" Crown I fig. 41 BECl'RlCAL PENETRATIONS . CONCRE1'EJMASONRY FLOORS & WALLS UI- SYSTEM W-L-3076 F Ratlna; 1 or 2 Hr - T Rmmg: 0 hr U'p 104" Cable Bundle CenteJ'l!ld In 4 - 112'" opening Sealant Depth: 518" v.11h 1/4" Crown l StwI SI_ 8alllgnt " eon"""" FIo<>r UL SYSTEM C-AJ.3154 F RatIng: 1, 2, 3 & 4 Hr . T R.3tlng: O. 112. & 2 3/4 Hr Or;nlonal Slee.oe-FVC or Steel El~ctrIcaI. TelephonS or D3lll CableS Annulus: 0" to Z' Sealant Depth: 112" Foming Mater1als: Nom II pef Mineral Wool Sealam Depth: 112" for 1, 2, 3 Hr; 3/4" for <1 Hr Fig" 5: BARE & INSULATED METALLIC PIPE PENETRATIONS. RATED GYPSUM WAllBOARD ASSEMBLIES UL SYSTEM C-A.l-8008 F Rallng: 31-1r . T Rating: 0 Hr Aluminum or Copper Bus Ducl 5,000 Amp Steel CcM3r Plate Sealant Depth: 112" Fonnlng Mater1~Is: Nom 4 p::r Mlnellll Wed Tlghtly Pa~ 108 depth of 1-117.' ~I)I UL SYSTEM W-L-1049 F RaUna: 1 t.:2 hr . T RatinQ: 0 Iv $lee! or Iron Pipe: 24". COpper I'tps: ll" Annulue: Point COn1aCl1O 1-314' SR.B1snt Dsplh: 518" WItt! 318" Cl1Jwn ~J Specified Technologies, Inc. UL SYSTEM W.L-5014 F RatIng; 1 & 2 Hr' T RatIng; 1 hr Steel or Iron Pipe: 12". CooperPIpc: 4" ln~laIed wllh 2' Thiel< ~Iber Glass or Mlner.31 Wool Pipe h"lSU\~lon Annulus: f1' 10 1-1/4" Sealant Depth: SIB' with 3Jg' Crow1 UL SYSTEM W.L.5051 F Ratlng: 1 & 2Hr - T R0llng: 1.1/2 Hr SleeI or Iron Pipe: 4", Capper P1,:.e: 4" Foam GI;$S F>lpe Insulalion: Z'Tt1Ick 12' WldA 0.01 (J' ThiCk M6llI1 Jacket VvTappo(l Around 1l1l3ulEllicn and $ecul13d with Metlll Banding ElS Sh(lWl1 A~nulus: a" to 3IfJ' Sealant Depth: 51fj www.atilirQ5top.com.ToIIFree800-992.1180 3 05/05/2005 10:21 2336747 Smoke Sealing: In some applications including nrestop col- lars. SpecSeal@ Series SSS Sealant Is recommended as a smoke seal. It is suggested in these applications that the sealant be applied to both sides of wails. In floor applica- tions. a sealing bead is suggested top and bottom. Cover Plate: In some designs a galvanized steel cover plate (26geuge) may be used to upgrade the fire resistance rating to 4 hours. Consult STI Produot and Application Guide for. dimensional and fastening requirements. LIMITATIONS: This product Is water-based and cures through the evaporeltion of water. Low temperatures, high humidity. the use of non-porous or Impermeable backing materials, cover plates or coatings may retard the drying process. Do not paint or seal in any way that prevents contact with air until sealant has dried through completely. This product has been designed to be safe with plastics and has been used extensively and successfully with a variety of different types of plastic pipes, tubes. and plamic cable insulations. Variations in these materials however, make It impossible to guarantee compatibility. STI strongly recommends that the user oonsult with the manufelcturer of the pipe. tubing, or cable in ques- tion regarding any known sensitivities or potential restrictions before applying this product. 7. MAINTENANCI! Inspection: Installations should be inspected periodically for TABLE D: ORDERING INFORMATION CAT. NO. DeSCRIPTION SSS100 10.1 oz- Tube (300 ml) 18.2 cU.in. SSS129 29 oz. Tube (85~ ml) 52 cu. in. S8S120 20 oz.. Sausage (592 ml) 36 cu. in. 888102 ;2 Gal. Pail (7.6 liters) 462 cu,ln. 888105 5 Gal. Pail (19.0 liters) 1.155 cuJn. Add/tIomII SpecSeeI hocfut:is- SSPFIrMtDp ~ Available both in bar fOnT! and In p~ds. putty provides eF.lllY retrofit forthrough-penetl1i!tions and economical proteetion 10r electrical boxes. SSB P'IrH1DP PIlIcwvs Durable. monolithic pillOWS for inatallations requiring quiCk and €21sy retroflttlng_ systems designed for pipos. cables f,lnd ceble tray in ~lIlypes of conRtruc:tion I J RASMUSSEN PAGE 05/09 subsequent damage. Any damage should be repaired using SpecSeal@ products per the original e1pproved design. Retrofit: When adding or removing penetrants. care should be taken to minimize damage to the seal. Reseal using SpecSeal<!!;1 produCts per the approved design. NOTE: New penetrants of a different nature than the original design may require a totally new firestop design or t;lxtensive modifica- tions to the existing design. Reseal all openings as per the requirements of the modified design. 8. TI!CHNICAL SERVICE Specified Technologies Inc. proVides toll free technical sup- port to assist in product selection and appropriate installation design. UL Systems, Material Safety Diilta Sheets and other technical Information Is available at the Technical LIbrary at www.stlflrestop.com. 9.. PRECAUTIONARY INFORMATION Consult Material Safety Data Sheet for additional Information on the safe handling and disposal of this material. Wash ar- eas 01 skin contact with soap and water. Avoid contaot with eyes. SEALANT IS CONDUCTIVE UNTIL DRY. 10. AVAILABILITY SpecSeal@ Series SSS Sealant is available from authori;ted STI distributors. Consult 'factory for the names and locations of the nearest sales representatives or distributors, Available packages and additional SpecSeel@ Product$ are listed be- low. IntumM(;eot wrap Sbtps ThreE! grades of intUfTl6scenl wrap strips provide an unmatcned combination of flexibility, economy, and expansion (up to 30X). Systems for plasrlc pipes inCluding FR Polypropylene up ro 8' rmde sizel MCIId8d I'IMstDp eon.m Easy to install, economical "rotectlon for ABS and PVC pipes (both solid end foam core) as well as CPVC. PVDF. end ~RPP. Callers available up to 6" trade size, CITY OF NEW YORK MEA 28-92M Impo",Int Nclb!!: o\Jllll9telT1'l"llI. IIlchnbll ill!oM1Slicln. E>">:l """"mmorn3llons contained ~n "'" besed "fXl" It!~ beI1ll'1ed to 00 11ll"b1n.1:xJt Ih~ BCCUI9::)I emd onm~ IMIllOi IS not g11~"'n!ot>d. WARRANTY: Specified T,:",:"oIO?I~e Inc. manur"",u",. It. ~od8ln e m9f1l1E'rtn bo f",,~ oT delects, Should env Clala",' "!:!cur In ~s goQas (wllhln nno )'CI~r). SpeclAed T<l~hnnlo9i"" Inc.. upon prom!)' noijllcellon. will "t k. "pllon. exchan~ or """,Ir rhe goods or '~un(llhn pun::1l8!l$ prlce Liml1allol1ll and F.i<c1U!llons: THIS wAAIlAN1YIS IN LIEU OF ALL OTf-lI;R REPRJ;SENTATIONS ExPRF.S-.<;ED OR IMPIJED (INCL!JOlNG THE IM~I ,lED W^RAANTIES OF MERCH^NT/lBILITY OR FITNESS .OR USE) AN[)lINOER NO CIRCUM$TANCf.~ SI"f\LL SPECIFIED l'ECt-lNOLOGIES INC. Be I'lIi.$PONSIBLE fOR ^NY INCIDENTAL OR eONSF.:QUENllAL PROPEm DAMf.GE OR LOSSES. PRIOR TO USE. TI'IE lJ5ER SI-I^LL DETERMINE THE SUITNllLllY OF THE PRODUCT FOR ITS INTEMOEO USE. ^NO THE U$F..R As."lUMeS ALL RISKS AND LIAB1LIlY FOR SU9SEQUF.NT USE. ~D ~I.atemem or racoml11ll<1cl:ltbn n~ contalll!ld ~n .1-..11 h>lvs env IOrce 01 ~ 1I~ " >In E1Qreemefll /IIClI"IecI by o"lm", of ""ikT;on:l rnsnufaeMa~ . . MADE IN THE USA - COPYRIG1"IT@ 2004. SPECIFIED rI;.CHNOLOGIES, INC, 4 www.~Il_Pop.ClOIt1 . Toll, ~Fll9 800-992.1180 II Specified '-STI Technologies · Inc. 200 Evans Way. somerville. NJ 08676 Phone; (000) 992-1180 . Fax: (90B) 526.9623 STI on \tie WEB: 'MWJ.sllflrestop.oom \~] SpecifIed TechnologiC', Inc. 05/05/2005 10:21 2335747 J RASMUSSEN PAGE 05/09 SIiL~-2tN)'llllll~ PRODUCT DATA SHEET Firestop Collars ReprodtJced from Electronic Media 1. PRODUCT DESCRIP'fION The SpecSea/(ij') Firestop Collar Is a factory..rnanufadlJred device designed to protect plastic pipes penetrating fire-rated walls and floors. UtIlizing a heavy gauge galVanized metal roJIar to house a molded intumescent insert. the SpecSeal@Collarisspecificallyslzedloflt 1-112". 2", 3",4", and 6" trade sized pipes. This product utilizes STI's pa~nted two-stage intUmescent technology, provlding a very responsive and highly dlrectionallzedexpansion. Expansion is extremelyfast, providing quick closure for burning combustible pipes. When exposed to temperatures In excess of250OF (121" e), the SpecSea/@Collar'smolded Insert begins to expand (Intumesce) rapidly to form a dense. highly insulative char. Its free expansion ranges m:rn 16-24 times original (pre-expanded) volume. expansion contlooes up to 1,??oo F. 2- APPLICATIONS specSeai!B) Collars are used to protedavarietyofplastic pipes including PVC. PVC Foam Core (ccPVC). CPVC,ABS,ABS Foam Core (ccABS). and FR Polypropylene In both vented ~WV) and closed (eIedrlcal conduit and water supply) installatiOns. specSea~ Collars are suitable 1br use in all oommon form$ of oonstruc.1lon including con<:rete floors, conaete OJer steel deck, conO'ete walls. concrete block walls. gypsum board walls. and wood floor assemblies. SpecSeal@ Collars are used alone or in combination, with other SpecSeal@ producls to protect a wide variety of nonmetallic pipe penetrations either irdlvldually or in combination wilh other typeS of penetrants. 3. PHYSICAL PROPERIlES See Table A This material is exI18meIy stable. Long tem'I aging studies indicate no signtflcant loss of physical properties nor significant change in expansion properties after elevated temperat1.re. humidity, and immersion testing. Consult factory for addlliohal infon'nalicn. 4. PERFORMANCE SpecSea~ Collars are the basis for systems that meet the exacting aiteria of ASTh1 EB14 (UL 1479). Systems have been tested for all common forms of construction and most common penetmn1s wiIh mtings up to three hours. STl designed firestop systems are ooglneered to maximize the fire resistance of the seal by not only sealing o1fthe spread of1ire and hot gasses but also by minimizing the amount of heat conducted through the assembly. Thus all systems have been designed to provide T RatIngs capable of matching the rating of the wan or floor assembly (where possible). Consult faclory tbr Infonnatlon not available in UL Fire Resistance Directory as of this printing. NOnce: The use of this product may be tegV#at8d by regiort81 or local codes. CONSULT THE LOCAf..AUTHORITYHAVING JURISDlCT1ON. 5. SPECIFICATIONS The firestop system shall be a factory assembled flrestop collar utilizing a molded two-stage, flexible Intumescent insert. The intumescent insert shall provide a minimum of 15X free expansion aod shall contain no water soluble expansion ingredients. The specified material shall be approved for a wide range of appli- cations includIng PVC. CPVC. ABS, ABS Foam Core, and FRPP pipes when used by itself or in combination with other products from the same manufac- turer- The collar shall be UL Classified and/or FM Systems Approved and tested to the requirements of ASTM E814 (UL 1479). SPECIFIED DMSIONS OIV. 7 07840 Through-Penetration Firestopping OW. 13 13900 Special Construction Fire Suppression & Supervisory Systems DIV. 15 15250 MechanicallnsuJation - Rre ProtaCtton ON. 16 16050 Basic Electrical Materials & Methods ~ llUll lIIROUGfl-PENETRATlON F1RatOll DEVICE CLAS$IFlEll BY UNOERWRrTERSLABOAATORIES INC. i SEE Ul. FIRE. RESISTANQ; DIRECTORY FEATURES .. Rapid Expansion: Closes off burning penetrants faster. . High VoIulI't8 Char. Expands over 20 times! .. WJdarI.Re8istant: No soIubte or hygroscopic ingredients. . economical: Factory assembly ' reduces field labor! .. Easy Installation: No guess work. . ApprovRd for a wide variety of pipes and constructions. For the latest Product and System Information, Call STrS FACTS"ON~DEMAND autGmated infonnation attendant system by dialing toll~frM (888)526-68001 STI Product tll'tA 9Nllll . Fl"'., !;oll_ FOO-5013 121~1I Pa~8 1 of 4 6. INSTALLATION GENERAL: The instaRation of1his product requires the app6cation of a smoke seal utilizing SpecSeal@ Serles SSS Sealant and suitable mechanIcal fasteners for attachment to the floor or waR surface. Sealant and flOOf or wall attachment hardware must be purchased separately. Any fasteners required to dose the conar around the pipe Itself are Included in the collar package. SYSTEM SELECTION: Proper methods and materlals are critical to flrestopping. A number of methods have been developed to suit a wide vartely ofllrestopping applications. Tables B and C have been provjded to assist in determining rI systems suitable for various applications. Furthermore, many installations have been llIustrated throughout this da1a sheet and nr:NJ ~s are continually being tesled. For more information consult your local disb1butor, sales rep. or call STI toll free at (800) 992-1180. SMOKE SEALING: Smoke seaRng is a vital s1ap in the fires10pplng process. , Sil1(:e proper smoke seal design wlII vary from one type of construction to another, STI has elected to require a separate seating step. A separate seal provIdeS for abnormalities in floor or wall surfaces (such as blow<luts in core drilled holes), variations in annular space, and preven1s the passage of smoke produced by deterioration of the pipe Itself within the wall or 1I00r cavlty. This seal in floor applications, also seals against water leakage into the floor cavtty in plumbing or mechanical installations. For additional information on this topic, request "Firestopping Plastic Pipes," SpecSeal@Technology Update. Smoke seals should be installed at the top and bottom surfaces offloor/ceifing assemblies. In solid concrete floors, a single seal may be installed at the ~er surface. It is strongly recommended however, thetan additional seal be caulked at the top side to seal against smoke generated within the floor cavity ilself. Smoke seals are required at both sides ofwood floor assemblies and hollow wall cavffies. . Apply sealant to a clean surface, free of dirt, oil, rust. or scale. Caulk annulus shut using a nominal 318" bead. Sealant may be smoothed out or the collar may be set dimclly into the wet sealant. NOTE: Collars Installed around pipes poured directly Into SpecSeal@ Mortar do not: require fhls sealing step. FASTENERS: IWmys use the COITect typeoftastener. ThefasteJ1ert)'pesused T8ble C. APPLICATION .NFORMATION A1in IPfa~shoustingldabere steelshown(le ind Ta~. DESCRIPI10II pfE SIZE ATTACtIMIOO' ANNlUR ilL SYS. NO, HOURLY FIG. ;;10"" '''' '" a or..........c FLOORIWALL CONSTRUCT. HARDWARE" SPACE RAnMG fasteners are unsuitable and should not be used). 11/4- or 1112"fenderwasher.; are used in conjundion with aD wall orfloor fasteners. AD fasteners should be Ins1aUed as per the recommendations of the manufactLlrer. CONCRETE: Expanding wedge type anchotS(1/4.x1314'~arerecommended. Powder activated fasteners may be used GYJIIlum Wanbolll'd at the discretion of the installer and are PVC. CF'VC.ABS, FRPP.PVDF subject to the recommendations of the PVC. CPVC. FR PP, ^9S fastener I1'I3nufaclurer. Wood Floor Dm"', WlBto, Vent Slack GYPSUM WALLBOARD: Toggle bol1sor PVC.ABS moWy-type expandlng anchors are suitable Wood ROCII' Slngllt Collar for collar attachment. PVC. CI'VC GYPSUM BOARD-WOOD FLOOR WoocI Floor DolIbltl Collar FLOORICEILlNGASSEMBLIES: Toggle pve. CPl/C bolls am suggested for gypsum wallboard ceiling attachment. Collars mounted internally and fastened to wood may use standard #8 x 112" round head wood SCl'eW$ for attachment. 06/05/2005 10:21 2335747 '.' Table A~ PHYSICAL PROPERTIES 1WlI11lIb1lt 8m SheD ConrltI'\ldocl 11'llurI1BlICll11..,t ElqllInBton B8ghI 1.5" ttru 8" 22 G1;I~ Gal. SIeeI Molded one pleoe, 250" F (1&1 slage) ~F(2nd_) 1610 24x (1l9U~nsian) "130. F. No Change (6O"C\" No Cl\angll (6O"C. 98% R.H.r \/ollmle EJIpmllIon In&NIce'tomp. Oven AgIng Hunlkllly Expoture . EvaWfiOn rlp~~lI!ldlD1al~ PeRe 2 or .4 J RASMUSSEN PAGE 07/09 Tab.. D: COLLAR DIMENSIONS - Mo! ~lAl ~I~I The following dlmel1!1!ons are provldlld for in~\allation pmpcsa~ only. All dlmllnsicns have be(!n roundad up 10 {na next 1110th In. "NOTE: (sea Below) The 'A' dlmtlnSlon for SSC800 I'lIpreseFl1s the max. width of collar allabs that are 1SOe oJlllOsed from each olhar. - -c- CAT NO: SSC151 SSC202 SSC301 SSC400 SSC600 Trade SI%o 1~1/1" 2'" 3" 4" S" A 4.2" 4.5" 5.SM 7.1" 11.2.... B 2.8" 3.2" 4.5" 6.2" 8.3" C 1.5" 1.5" 2" 2" 4" Com;reIIl Floor PVC, CPVC. ASS, PVDF FRPf' PVC, CPVC, FR pp, ASS S:4" s:4" ft ~112" SII2" s112" ('AI.2038 CAJ.2045 CAJ-2089 :;:3 !:2 !:3 J,4 3,4 '3 CClm;m.. or Block Wall P\lC, CPVC,ABS, P\IDF FRF'P PVC, C?VC. FR PF', ABS CAJ.;zo3B CAJ.2045 CAJ.2089 :>3 $2 ~3 5.6 5,6 5 $4" :$:oiI" 6" !:112:' ~112." $112" :!!::4" 6" ' 201'3 2<<3 WL-2029 Wl-2074 ~2 s:2 7 7 $112" $112" $4" 4 $1/'t' Fc.2034, ~5 ~4" 3 $112" Fc.2020 :;;2 8 S4" 3&4 s1/2" F~021 ~2 9 . AllACHMENT HARDWARE CODE: (Fender washer!! ere recommended and often requhed) 1 " Concrete wedge ancl!ln, 2 c Sll3e1 molly.type f85teJlBl'S S " 31'16' Toggle bolts. 4 " lIS X 112" 1'llUIld head wtlOd SCl'llWS. NOTE: PVC iii ABS IIRIlppnJWd for solid or c:ellulllt cant piping up 10 four Inch tI<Ido ,IZll, STI P",d_ Dma SlI&et. FI-top Cui"'... FOD.,,01~ 1,,/1lQ 06/05/2005 10:21 J RASMUSSEN 2335747 Fig 1 MllllCllllY And'lOl' Fig 3 P188t1c; PfP8 SlIeItlnl Ullllzgd AS Smoka SlIaI ~ .0 of. 4 <l of <1 .. t J lrrbmtaC8nt InsOrt st\tB1i= Shill! INSTALLING INTUMESCENT INSERT' INSTALLATION PROCEDURE: 1.Apply smoke seal (see above). 2. To install collar around pipe: Flex intumescent Insert. followed by the outer steel shen 8roood pIpe (See Fig- 1). Close s1eeI sheH around insert and fasten by crimping tab oIoswe for SSC151. 202. and 301 models (see Fig. 2), or by bolting shell together using supplied fasteners (SSC400 & 600 models). Snug fasteners sufficiently to allow collar to slide, 3. Slide collar to wall or floor surfaoo and mark anchor holes for drilBng. 4. Drill holes and install fasteners as per the requirements of the fastener manufacll.Jrer. Place 1 114" fender washers of the appropriate c6ameter r:Ne't fastener at collar mounting tabs and tighten anchors fully. 5. Recheck and tighten shell bolts ftlllyto complete instanation. 7. MAINTENANCE INSPECTION: InstBnationsshould be Inspected perioclically for subsequent damage. Any damage should be repaired using SpecSeai03) products per the original approved design. RElROFIT; When adding orremovlng penetrants, care should be l:eken to minimize damage to the seal. Re~al using SpecSea~ produdS per the approved design. NOTE: New penetrants of a different nature than the original design may require a totally new firestop design or extensive modifications to the exlsltng design. Reseal all openings as per the requirements of the new design. B. TECHNICAL SERVICE Specified Technologies 100, provides toll free ted1nical support to assist in produd selection and appropriate InstallatJJn design. Design System Dra\Nings suitable for submltlal or spec:lficationpurposes are available on request. 9. PRECAUTIONARY INFORMATION Consult Material Safety Data Sheet for additional information on the safe handling and disposal of this matertal. Wash areas of skin contact with soap and water. Avoid contact wltt1 eyes. F112; SIC151. 202 & 301 CRIMP CL08URIE & MOUNTING PAGE 08/09 Fig 4 4A of A Meoonry An~ S~I. SSC301 COliill' Fi9.5 SpecS8lI11l!I .. .. Collar Conc:ilWhI or BIodc WIlli .. .. FIg 6 ... SpeeS8llIa. SSC301 Collar of . CoI1I;r818 elf Block waI PQge 3 or 4 $" ProdlJC'! Of'l. Shftet .. F'....tcrp Celllllllnl- 3. Crimp tabs closed using pRem. 4. Fasten 10 wall or floor. FOO.~OlJ 1219il 1. Wrap collar around pipe. 2. Press tab into slot. 05/05/2005 10:21 2335747 Flg7 ~4 .... SlIGI,.,t UU~ M ~$MII Taggle Belt I~ CoII8r I Fig 9 PlyWOod SUbftDar GypsumJ WaIltlO8rC:l !!leallUlt Utlllzed NJ SITltlkB Seal Toggle Bolt J RASMUSSEN PAGE 09/09 10. AVAILABILITY SpeoSear Rreslop COIIam are available from authoriZed 511 distr\blJtOIS natio,r1Wlde. Consult f\:lCtOIY for the names and locations of the nearest sales represenlBtiVeS or dIstributOrS. Available packageS and additional SpecSeaf'b ProductS are !\sled in Table D. Table D: ORDERING INFORMAnON Cat. Mo. SSC151 M'DMe Oellcrlptlon Firer.lop Collar Fits 1-112" Trade size pipes. Utilizes crimp closure. SSC202. Firestop Conar Fits 2ft Trade si%a pipes. Utilizes crimp closure. SSC:;101 Firestop coller FilS~" Trade sl<:e pipes. Ubllzes crimp closure. SSC400 Flrestop Collar Fits 4" Trade size pipes. Utilizes bolt closure, bolls InclUded. SSC600 Flrestop CoII{lr FIts e" Trade size piper.. Utlllze$ bolt closure, br;l1ts Included. Additional SpecSeal Products... SMte9 SSS Sealant The indUsl!y'll most veraatlle sealant provides the ftrestcppplng solution!;! for a wide range of combUstlble and ntlneombulltible ,appllcatJon$. Water--beMd Intumascent sealant elCpands up to 6xI Serles LC Sealant An economical latex fln;!stoP sealant for noncombustible applications. NOr)otll;llogenate<l. easy clean up, flexible. water- I'llSlst9ntl SSP Flreatop PuttY Available both ill barform and In pads. putty pmvlde$ easy retrofit for through-penetratiollS and ecQfIOITIiClilI protection for eleetrlcal boxes. sse f'1res10p PIlIOW& DUl'able. monolithic: pllloY/5 fOr inslallirtiOns requiring quick and eer.y retrafilllng. SyS10ms designed for pipes I cables ~ncl cable tray In an types of cona'InJc:lkml FlntBlep Mortar LlghlWalght, versatile and economical! The bast chOic& for large or complex Insmllations. Pensl" Silicones SealardS and 1bam forthrough~netfstkms and constructionJointa. UnexceDed aging characteristiCS and flexlbnlty. Intume&cent Wr8p Strfps 1\vo grodllG of intumescent WI':!Ip sttips provide an unmatched oombinatlon of flexibility, eoonomy, and expanslOl1 (up to 30X). Systems for plasflc pipes including FR polypropylene up to aft trade slzel Elastomer1C Joint Seats New economical produr;ta for se~lling constllletion )oin1S. Chooaa caulk or spray applied products testad to VL.2079. CITY OF NEW YORK MEA 307-92M Impoltant Nallco: N1 ststal"lllll11!t, lechnicallntcnnation. 11m! recOmmendallot'l$ contained herein are baaed upOn lesdng belloved III 17$ l'$Ileb4e. but 1M accuracy !!1M compl0leneBll thamof 19 IICt gl/al8ntaed. WARRANTY'. Specllled 1lrlIIIol~ 'PIC. IT18l'I\If<IClU191l Jlll goodllln II M3IlI1Sr In be Il'ee of detllets. Should lIny defect occur In lis gootl"!1 (wllhln one year). Specllled Tee/lnologloo Ine., upon prompt notitteHllon. will 1lI: il!I optlcn, ~ehBnQs or ~Ir!he good!! Dr refurld lh9 purchase price. Umlllltlone and Exclut:lolltl: THIS WARRANTY IS IN UEU OF ALL OlHER REPf/.ESENTATIONS EXPRESSED OR IMPUED (1NCWOING THE: IMPWED WARRANTIES OF MERCHANT~ILITY OR F"ITNESS FOR USE) AND UNDeR NO CIRCUMSTANCES SHALL SPECIFIED TECHNOLOGIES INC. BE RESPONSIBl.E. FOR ANY INCIDENTAl. OR CONSEQUENTIAL PROPEFtlV DAMAGE OR LOSSES. PRIOR TO USE. neE uSER SHAll. DETERMINE 1l1E aUITA8'UTY OF THe: PROC\JCT FOR ITS INTENDED USE.. AND TJ--IE USE:R ASSUMES ALL RISKS AND I.IA61LITY FOR SUBSEQUENT USE. NO stBtamentorl'8COmmefldlllllon notCOt'rl~lned he~ir1 sM11 00'19 anyfm:e oreffocl unleSS in Illn Bg~t signed by ofIIcsl'!l ofllellgr and mBn~l'llr. MADE IN THE USA - COPYJtIGHT e 2tlOO SPECIFIED TECMNOLOGlES, INC. ~ Specified STI ~~~ologies 200 Evans Way A Somerville, NJ 08876 PhOne: (800) 992-1180 A FalC: (908) 526-9623 Facts.on-Demand: (888) 526-6800 STI on the WEB: www.stJfirestop.COOI pftg.. <I Df 4 STI Pmduef DAIA SI1RoI . ",",,,top Collars FQll.!!013 121M