Job Address 3001 S WASHBURN ST
CITY OF OSHKOSH No 119006
BUILDING PERMIT - APPLICATION AND RECORD
Owner FIRST HORIZON GROUP LIMITED PTNSHP Create Date 0411212006
Designer
Contractor WARWICK CONSTRUCTION INC
Cate90ry
232 - Alteration Stores & Customer Service Plan R9-14-0206
Type
. Building
o Sign
o Canopy
o Fence
o Raze
Zoning
Class of Canst:
Size
Height
o Ft.
o Projection I
Unfinished/Basement ~ Sq. Ft.
Rooms
o
o
o
Stories
Canopies
o
o
Finished/Living
~Sq.Ft.
~Sq.Ft.
Bedrooms
Garage
Baths
Signs
Foundation . Poured Concrete 0 Floating Slab
o Concrete Block 0 Post
o Pier 0 Other
o Treated Wood
Occupancy Permit Required
Flood Plain
Height Permit
Park Dedication
# Dwelling Units _--2
# Structures
o
Use/Nature fSpace 070 I The Gap / Interior alterations for new tenant.
of Work
HV AC Contractor
Plumbing Contractor
Electric Contractor
Fees: Valuation
$311,563.00 Plan Approval
$0.00 Permit Fee Paid
$835.00 Park Dedication
$0.00
Issued By:
Date 0411912006
FinaIIO.P. 0010010000
o Permit Voided I
Parcelld # 1329420000
In the performance of this work I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement
holder(s) and to secur y necessa rovals before starting such activity.
Date 7-1'-tJ~.
Signature
Address 365 FM 1959 SUITE A
HOUSTON
TX 77034 - 0000 Telephone Number 832-448-7003
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
~
OfHKOfH
Spc-.<.-e.. 0'10
City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903-1130
www.cLoshkosh.wi.us
~-
ON THE WATER
April 10, 2006
Robert Tindall
Callison Architechts, Inc
1420 Fifth Ave # 2400
Seattle WA 98101-2343
Duane Henderson
Henderson Engineers Inc
8325 Lenexa Dr, Suite 400
Lenexa KS 66214-1654
Felice Arredondo
Prime Retail
217 E Redwing, 20th Floor
Baltimore MD 21202Name
Site: Plan Number: R9-14-0206
Gap Ontlet
3001 S Washburn St
Oshkosh WI 54904
For:
Description: Tenant space alterations
Object Type: Building and BV AC
Class of Construction: fiB - 12502 Sq Ft.; SprinkIered
Occupancy: M: Mercantile I Retail
Maxinrurn No of Occupants: 337
The snbmittal described above has been reviewed for confonnance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defmed in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Item(s) I Conditions:
. IBC 711.3 Any penetrations of fire rated assemblies are required to be protected with a listed firestopping
system that matches the rating ofthe walI assembly being penetrated. Copies of the firestopping systems
are required to be provided at the time of inspection.
. IBC 901.2 Fire protection systems shalI be instalIed, repaired, operated and maintained in accordance with
this code and the international fire code. (Construction of new walls may require the addition and or
relocation of sprinkler heads to maintain required coverage, and not obstruct spray paUerns offire
sprinklers)
. IFC 901.4 Fire protection systems shalI be maintained in accordance with the original instalIation
standards for that system. Required fire protection systems shall be extended, altered, or augmented as
necessary to maintain and continue protection whenever the building is altered, remodeled or added to.
Alterations to fire protection systems shalI be done in accordance with applicable standards. Submit plans
for fire sprinkler modifications.
. IBC 906.1 / IFe 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet.
. IBC 1003.2.10 Exit signs are required to be installed per this section
\\OSIIKOSTflVf.TSF$\I..JSER$\briann\2006 Comm PlanRevie\\'\R9~1.4,.Ol06 ::tOO! SWashhum St Bldg &: IIVAC.doc
Page 1 of3
-co
. IRC 1003.2.11 Means of egress illumination is required to be installed per this section. All paths of egress
through The Retail Display area are required to have adequate emergency lighting to meet the performance
requirements ofIBC 1003.2.11.3.
. IRC 1101.21ANSI A117.1-308.2 & 3 -Mechanical system controls shall be located a maximum of48"
above the finished floor if the floor space allows a forward approach by a wheel chair or if the clear space
allows a parallel approach.
. IRC 1209.1 Provide toilet room floors with smooth, hard, nonabsorbent surface extending minimum 6
inches up onto walls.
. COMM 62.1109 (12) Where counters are provided for sales or distribution of goods or services, at least
one of each type provided shall be accessible.
. IRC 2406.2 Glazing in an individual fixed or operable panel adjacent to a door where the nearest exposed
edge ofthe glazing is within a 24 inch arc of either vertical edge ofthe door in a closed position and where
the bottom exposed edge of the glazing is less than 60 inches above the walking surface is requires safety
glazing materials. VerifY that these requirements are met at new door openings in store front.
. IRC 2902..1 / Table 2902 Drinking water is required to be provided, since no drinking fountain is shown
on plans a bottled water cooler is required to be provided. Revised plan will be submitted showing water
cooler being relocated as part of toilet room relocation plan.
. IFC 901.4 Fire protection systems shall be maintained in accordance with the original installation
standards for that system. Required fire protection systems shall be extended, altered, or augmented as
necessary to maintain and continue protection whenever the building is altered, remodeled or added to.
Alterations to fire protection systems shall be done in accordance with applicable standards.
. IMC 302.1 The building or structure shall not be weakened by the installation of mechanical systems.
VerifY that existing structure is capable of supporting the additional weight of the proposed roof top
equipment.
. IMC 304.9 Guards. Guards shall be provided where appliances, equipment, fans or other components that
require service are located within 10 feet (3048 mm) of a roof edge or open side of a walking surface and
such edge or open side is located more than 30 inches (762 mm) above the floor, roof or grade below. The
guard shall extend not less than 30 inches (762 mm) beyond each end of such appliance, equipment, fan or
component and the top of the guard shall be located not less than 42 inches (1067 mm) above the elevated
surface adjacent to the guard. The guard shall be constructed so as to prevent the passage ofa 21-inch-
diameter (533 mm) sphere and shall comply with the loading requirements for guards specified in the
futemational Building Code. Caution on location of RTU's along roof edge.
. IMC 401.5.1 Mechanical and gravity outside air intake openings shall be located a minimum of 10 feet
from any hazardous or noxious contaminant such as vents, chinmeys, plumbing vents, streets, alleys,
parking lots and loading docks.
. IMC 405.1 Mechanical ventilation systems shall be provided with manual or automatic controls that will
operate such systems whenever the spaces are occupied. Air conditioning systems that supply required
ventilation air shall be provided with controls designed to automatically maintain the required outdoor air
supply rate during occupancy.
\\OSIIKOSJI~USF-S\l..jS,EJ.(S\briann\2006 Comm Phm Review\R9-1.4-O'106 JOOl S\Vmihbum Sf mdg & IIV..\C.doc
Page 2 of3
"".
. IMC 606.4.1 The duct mounted smoke detectors shall be connected to a fire alarm system.
. Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm61.31(1).
. MUN 30 This review does not include review for signage. Applications for and questions regarding
signage permits should be directed to David Buck - Associate Planner (920) 236-5062.
. MUN 30-35 (1)(5) All roof top and ground level mechanical equipment and utilities shall be fully screened
from view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236-
5062 for additional information on screening requirements. All screening shall be properly anchored in
place to resist wind loads. Additionally mc 1608.8 Roofprojections - Drift loads due to mechanical
equipment, penthouses, parapets and other projections above the roof shall be determined in accordance
with Section 7.8 of ASCE 7. Screening to be installed per plans
· Comm 5.34 No person may perform structural welding unless the person holds a registration issued by
Department of Commerce. Provide welders registration nnmbers for all people doing welding on this
project
SUBMIT:
· IECC 503.3.3.7 [Comm 63.0503(2)(t)] Balancing and documentation of the HV AC system shall conform
to the IMC. Balancing report required to be submitted prior to final occupancy being allowed.
. Comm 61.30(3) This review does not include lighting. Comm 63.0001 Prior to installation, lighting
plans and calculations shall be prepared in compliance with the code. Please submit lighting work sheets.
· Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All pennits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead.
nan oe
Building Systems Consultant
(920) 236-5051 Monday - Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to I :30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
Fee Required $
Fee Received $
Balance Due $
1110.00
1110.00
0.00
\\OSTIKOSIIM.JSFS\USERS\briann\2006 Comm Plan Revieiv\R9-14-0206 )(JOI S W"sbbun1 $f I11dg & nVA(',doc