HomeMy WebLinkAbout0118876-Electric ~ OSHKOSH ON THE WATER Job Address 110ALGOMABLVD CITY OF OSHKOSH No 118876 ELECTRIC PERMIT - APPLICATION AND RECORD . Change 0 Temp Owner ALGOMA BUILDING LLC Create Date 04/05/2006 Category 643 - Commercial-Addition/Remodels Plan 0 N/A Type 0 Overhead . Underground Circuits ~ Fixtures ~ Switches -~ Receptacles 0 Contractor PROGRESSIVE ELECTRICAL SERVICE: Service p New Volts 120/208 Amps 600 Appliances ~-::::~. " r-" ""- ~ ~ -, - '- '0" , ,-"' ,- ~ ,_. ~ -, ,-, "'"« Fees: Valuation $45,000.00 Plan Approval $0.00 Issued By: -~ a~~ n ~. -- 0 Permit Voided I Permit Fee Paid ~19.00' Date 04/10/2006 Parcelld # 0700060000 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is nota party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Address N9403 NOE RD Agent/Owner APPLETON WI 54915 - 9370 Telephone Number 920-766-9626 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i,e, Footing, Service, Final, etc,), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. Ci!)l örO<Moosb Dïvis¡œofl"'~¡~!iS<:r>l¡"*s P.O. &~ IU() omkœh, 'flv'l 54903-mO Ph""", (920) 23~5œ;;Q' .1'"" (no) 23~5DM EI..ECTmCAl PERMIT APPLICATION AU im;,nmlioJl! ~fter bold Cì:!teg"ries ::œ~t be !\mvidod. 1"comp!~w "WlicatJoos wi!i !lot be proc~~od. .. AwJi<mlion(s) md lee(s} csn bi~bt"ug¡'tto City Halt Rooml0;t ol'mailed 10 1t~I¡on Servi"es, PO 1'1"" 1128, O:diko$h WI 5400:;.11211. Comillmcing wenc wi¡hout permii($) wjJj fej;u!t in fees bcing doubled 01' $. !OO.OO pius the !J.,=I pcmi!t f~. wmell ever is gr""ter- OR DATE 'l- '..;!tef C1ŒCK 1i1I. ALL M'l"UCAJ1U!; USE CATEGORY IlliMuJti-Fmnily £JRcntal OCommereia! OIndmtria! SERVICE IIN~w OCh~ T'j{PE OOve~ Ii!!UI1<1.;rgroi1nd DN"t Applicab¡e }'lLL:!:N Tm: A.l'l'ROI'RlATE BLANI{ "'un 1m;~:.R R"e¡Jtm.d~.:! 11_.- C'Ii'Cllits #_-.---:.......- Swit.clli!$ 11______-- F!xtl!l.,i!Mi #_--~ Cm:CK h1jALL M'PUCA.nLE ß'kange OF." 011 Blower OMoto!'S ~¡sh~cr !':Wm1åœ OGIJ.$ !:'-mnps OGm'ooge Disposal !3:;(¡c - !avlal~I' Healer Sigr¡ . DESCID:Ml0N .-......------.-----..-..--,--.--- 45"1~ 3/1.>2 913 39';'d VG%99LøG6 Eø :613 9øøG/9ø/vø ED By: '\i\! D{ f~: .",.) .,.' z".... Wisconsin Public Service Attn: Sally Fax: (800) 305-9794 Load calculations for 110 Algoma: HVAC (8) Gas Furnaces @ 900 VA (1)GasBoiler@1100VA (8) AlC Units @4000 VA 7200 VA 1,100VA 32,000 VA General Loads General LiQhtinq 1200 Sq. Ft. x 3 VA " 3600 x 8 Units" 28,800 VA Small A¡:JPlian~ 1500 VA x 3 Circuits x 8 Units = Dishwasher, 950 VA x 8 Units Water Heater, 5000 VA x 8 Units Range, 8000 VA x 8 Units 36,000 VA 7,600 VA 40,000 VA 64,000 VA MisceHaneous Lobby - Corridor 1000 Sq. Ft x3VA Electric Heat, 5 KVA 3,000 VA 5,000 VA Total Demand Factor 224,700 VA x 42% = 224,7011 VA 94,374 VA !M.374 VA 208V xp--- 262,15 Amps Not~ Future Commercial Offices Not Included EØ 39\id ÞZ:9599L0Z:5 EØ :50 900Z:/90/Þ0 April 5, 2006 City of Oshkosh Electrical Inspections Dept. Attn: Kevin Benner Fax: 236-5084 This notice is to request permission to use .MC Cable at the 110 Algoma Street Building (dweìlìng units only). Thank YOll, ¿ j Jay A. Blasewitz President Progressive Electrical Services, Ine, Phone: (920) 766-9626 Fax: (920) 766-9624 Mobile: (920) 378-0749 ìay(â!progressíveelecJ.:om <::0 39\1d Þ<::%99LO<::5 £0 :50 900<::/gO/ÞO Job Address 110ALGOMABLVD Electric Permit Work Card Permit Number 118876 Create Date 04/05/2006 Owner ALGOMA BUILDING LLC Contractor PROGRESSIVE ELECTRICAL SERVICE! Category 643 - Commercial-Addition/Remodels . ChangeO Temp 0 NIA I Type 0 Overhead Circuits ~ Service p New Volts 120/208 Amps ~ . Underground 0 N/A Fixtures 0 Fee ~D Receptacles Value $45,000.00 Switches 0 Appliances Use/Nature of Work Commercial/ Apartments- Convert the upper two floors into 8 apartments. does not include the lower ["~' Inspections: Date 04/19/2006 Type Rough In Inspector Kevin Benner Requested rough and Service for Tuesday 2nd floor only. Splices were not done & the ground tails wer not installed. Furnaces were installed in the adjacent units for some of the apartments, DatelTime requested: 04/14/2006 07:35 AM Access: Meet Nate on site. Notice Type: Phone Number: 378-0749 Ready Date/Time: 04/18/2006 07:35 AM Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid Jay - Progressive..Elec Date 04/19/2006 Type Service Inspector Kevin Benner approved wlcond, The labeling of disconnects and meters was not done because the feeder Approved to energize. Faxed to WPS 4/20/6 DatelTime requested: 04/14/2006 07:06 AM Access: Notice Type: - Phone Number: 378-0749 Jay Ready DatelTime: 04/18/2006 00:00 AM Requested by: 0 Reinspect Fee 0 Fee Wavied 0 Reinspect Fee Paid PROGRESSIVE ELECTRICAL SERVICES