HomeMy WebLinkAbout0118859-Building
-0
OSHKOSH
ON THE WATER
Job Address 149 W 24TH AVE
CITY OF OSHKOSH
No
118859
BUILDING PERMIT - APPLICATION AND RECORD
Owner 149 W 24TH AVENUE LLC
Create Date
04/06/2006
Designer
Contractor
OWNER
Category
131 - Multi-Family Addition
Plan S3-28-0306
Type
. Building
0 Sign
0 Canopy
0 Fence
0 Raze
Zoning
Class of Const:
Size
Unfinished/Basement
----" Sq. Ft.
----" Sq. Ft.
Rooms
Height
Oft.
D Projection I
Finished/Living
Bedrooms 0
Stories
Canopies 0
Signs
Garage
----" Sq. Ft.
Baths
0
Foundation
0 Poured Concrete 0 Floating Slab
0 Concrete Block 0 Post
0 Pier
0 Treated Wood
. Other
Occupancy Permit Required
Flood Plain
Height Permit
# Dwelling Units 1
# Structures
0
Park Dedication
Use/Nature ¡o.partmemt Building/Interior alterations to convert former office/meeting area into a dwelling unit.
ofWork
HVAC Contractor
Plumbing Contractor
Electric Contractor
Fees: Valuation
$2,000.00 Plan Approval
$0.00 Permit Fee Paid
$26.00 Park Dedication
$0.00
Issued By:
Date 04/06/2006
Final/O.P. 00/00/0000
D Permit Voided I
Parcelld # 1411450100
In the performance of this work i agree to perform all work pursuant to rules goveming the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement
holder(s) and to secure any necessary approvals before starting such activity.
(}LtA~ rR. ~ .
Agent/Owner
Date ~,;..- ?-Ob
Signature
Address 601 B OREGON ST
OSHKOSH
WI 54902 - 5965
Telephone Number
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
CITY OF OSHKOSH - DEPT. OF COMMUNITY DEVELOPMENT
SITE PLAN REVIEW - ZONING
Location of Property: ) L¡ <Or
81<:.-1,,5
~:!- c Date:
Lf/S/O6
Applicant Name: ~ L.-, '-1'--<- f? Phone:
Applicant Address: \ '-1"'\ ,~1.1.\: \ k City:
Owner: ~~v-r<-¡'" Ç'(,/¡-2..f r1f;;" Parcel Nwnher(s):
Type ofConstruction:C\-..,..,\)<..".t ~ c,c4W¡{rê, {C~ 10 JA,u,I(v,,- Uvj' J-
./
Fax:
State: _Zip:-
Zoning: CL
i~ }'C;-rl\,
COInpliance Checklist
Use
LatWidth
Lot Depth
Lot Area
Floodplain
Airport
Height
Front Setback
Corner-Side Setback
Interior-Side Setback
Rear Setback
Building Area
Access Regnlations
Parking Standards
Loading Standards
Vision Clearance
Trans. Yard Standards
Screening
Landscaping
Lighting
Signage
Mechanical Screening
Var./CUP/PD Conditions
Other
Comments/Conditions
kO(Þ\'1-!j
I ~ vIA I oJ
) -s / Océjfe¿ \..,
ÚI¡'r
L.Ù~5d ð S
/C-
? (' ~-; t- '-7
~\()~r é~ ((?,c,
\ S
\ \~ It¿ ¿
+ 0 .~:;'O
Iv
Q Y--- r{-,~1<)IOv')
Review Fee:
(Disturbed area" 10,000 sq ft- $100 / > 10,000 sq ft= $200.00
Signage = $25
FJoodplain = $75)
/"",~Àpproved D. Approved w/Conditions
/"'" ../-2 /~
Reviewed by: / ...---::
0 Denied 0 Hold
Review Date: <7/-7ß;t:
Please contact the Zoning Administrator at 920.236.5062 if you have any questions.
REVIEW AUTHORITY
'" ",s"",," 3<>-5 E"ro~"""" of"" Ci<yZoo;"g """""~, "" Di=<worC"""""'¡<yD=1- 0<'-',"" ",,",~.I p!æu. ~_<h,tbUowmg, (I) Alt=¡,m w ;"torio<
w,",w"" <h"",.""ronnmg"""""" ooclw>g';, œ,"pro"". (2).....~~~_".g._&w;"d_",.,wh~""""'ro"fonnmg""'whrnro_g,'-
.."",,""'.29.05.0100
~
OIHKOJH
City of Oshkosh
Division of Inspection Se",ices
215 Church Avenue
PO Box 1130
Oshkosh WI 54903-1130
www.cLoshkosh.wLus
ON TH< WATER
April 3, 2006
Chet Wesenberg
Chet Wesenberg Architect LLC
3162 Hayward Ave
Oshkosh, WI 54904
Schwab Properties
601 Oregon St
Oshkosh, WI 54901
Site:
Bethany Estates
149 W 24th Ave
Oshkosh WI 54902
Plan Nnmber: S3-28-0306
For:
Description: Convert common space into living nnit
Object Type: Bnilding only
Class of Construction: VB - 755 Sq Ft.; Unsprinklered
Occnpancy: R2: Residential
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The snbmittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Item(s) I Conditions:
ANSI 303.4 Changes in level greater than Y, inch shall be ramped in compliance with Section 405 or 406.
VerifY that entrance / exits meet accessibility requirements.
706.4 Continuity. Fire barriers shall extend from the top of the floor/ceiling assembly below to the
underside of the floor or roof slab or deck above and shall be securely attached thereto. These walls shall
be continuous through concealed spaces such as the space above a suspended ceiling. The supporting
construction shall be protected to afford the required fire-resistance rating of the fire barrier supported
except for I-hour fire-resistance-rated incidental use area separations as required by Table 302.1.1 in
buildings of Types lIB, llIB and VB construction. Hollow vertical space!! within the fire barrier wall shall
be firestopped at every floor level. VerifY that existing walls to become rated walls have been properly
constructed to meet rated wall requirements.
1BC 707.5 Continuity. Shaft enclosure walls shall extend from the top of the floor/ceiling assembly
below to the underside of the floor or roof slab .or deck above and shall be securely attached thereto. These
walls shall be continuous through concealed spaces such as the space above a suspended ceiling. The
supporting construction shall be protected to afford the required fire-resistance rating of the element
supported. Hollow vertical spaces within the shaft enclosure construction wall shall be firestopped at every
floor level. Provide details showing proper construction ofHVAC chase as required to meet code
requirements.
ftlbriann'20()(i Camm Plan Rcview'.S3-28-0306 149 IV 24th Ave ßI¡Jg Only.doc
Page I of3
IBC 711.3 Any penetratiQns.offi~e rated assemblies are required to be protected with a listed firestopping
system that matches the rating of the wall assembly being penetrated Caution on potential rated floor
penetrations. Copies of the firestopping systems are required to be provided at the time of inspection.
IBC 714.2.3 Doors in corridors and smoke barriers. Fire doors required to have a minimum fire-
protection rating of 20 minutes where located in corridor walls or smoke barrier walls having a fire-
resistance rating in accordance with Table 714.2 shall be tested in accordance with NFP A 252 or UL IOC
without the hose stream test. If a 20-minute fire door or fire door assembly contains glazing material, the
glazing material in the door itself shall have a minimum fire-protection rating of 20 minutes and be exempt
from the hose stream test. Glazing material in any other part of the door assembly, including transom lites
and sidelites, shall be tested in accordance with NFP A 257, including the hose stream test, in accordance
with Section 714.3. Fire doors shall also meet the requirements for a smoke- and draft-control door
assembly tested in accordance with UL 1784 with an artificial bottom seal installed across the full
width of the bottom of the door assembly. The air leakage rate of the door assembly shall not exceed 3.0
cfm per square foot (0.01524 m3/slm2) of door opening at 0.10 inch (24.9 Pa) of water for both the
ambient temperature and elevated temperature tests. Louvers shall be prohibited.
IBC 714.2.7 Fire doors shall be self closing or automatic closing. The door schedule included in the
plans does not show closers for the added fire doors. All hardware installed on rated doors is required
to comply with NFP A 80 requirements for hardware on rated doors.
716.2.2 Concealed wall spaces. Fireblocking shall be provided in concealed spaces of stud walls and
partitions, inclumng furred spaces, at the ceiling and floor levels and at IO-foot (3048 mm) intervals both
vertical and horizontal. Install proper fireblocking at tub chase.
IBC 906.1 / IFC 906.3 The maximum travel distance allowed to a fire extinguisher is 75 feet.
907.2.10.1.2 Groups R-2, R-3, R-4 and 1-1. Single" or multiple-station smoke alarms shall be installed
and maintained in Groups R-2, R-3, R-4 and I-I, regardless of occupant load at all of the following
locations: I.On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of
bedrooms.
2. In each room used for sleeping purposes.
3. In each story within a dwelling unit, including basements and cellars but not including
crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and
without an intervening door between the adjacent levels, a smoke alarm installed on the
upper level shall suffice for the adjacent lower level provided that the lower level is less
than one full story below the upper level.
IBC 1009.1 / Comm 62.1009 In Group R occupancies and Group I-I occupancies. Provide emergency
escape and rescue opening in accordance with this section Openings shall be a minimum of 5.7 sq ft in
actual clear opening (5 sq ft on grade floor(s» and minimum of24" high and 20" wide with a maximum
sill heightof 44".
IBC Ú06.2 Air-borne sound.. Walls, partitions and floor/ceiling assemblies separating dwelling units
from each other or from public or service areas shall have a sound transmission class (STC) of not less than
50 (45 iffield tested) for air-borne noise when tested in accordance with ASTM E 90. ThisJequirement
shall not apply to dwelling unit entrance doors; however, such doors shall be tight fitting to the frame and
sill.
Ihbciann'.2006 Comm f'hm Roviow'.S3-28-0306 149 W24ù, Ave Bldg Only.don
Page20f3
Comm 61.30(3) / IMC 507.2 This plan review does not include heating, ventilation, or air
conditio~ing. HVAC plans are required to be submitted and approved prior to installation ofHV AC
equipment. Be aware that IBC 1004.3.2.4 contains additional restriction for air movement in corridors
Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
authorized representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with.
Comm 61.31(1).
SUBMIT:
. Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
A copy ofth.e approved plans, specifications, and th.is letter shall be on-site during construction. All pennits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to reqnire changes or
additions should conditions arise making them necessary for code compliance.) As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inqniries conceming this correspondence may be made to me at the number listed below or the address on this letterhead.
_Re~
~~
Bnilding Systems Consultant
(920) 236-5051 Monday-Friday 7:30AM. to 8:30A.M and 12:30 A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
Fee Required $
Fee Received $
Balance Due $
320.00
320.00
0.00
W'.b,i¡um'20ûÚ Comm Plan Rcvicw\S3-2S.030(i 149 W 24Ù, Ave BI¡Jg Only. doc
Page 3 00
BUILDINGS, HV AC, COMPLIANCE STATEMENT 88D-9720
This form is required to be submitted by the supervising professional (architect, engineer, HVAC designer or electrical
designer) observing construction of projects within buildings with total areas 50,000 cubic feet or greater and bleachers
(Comm 50.1 O/Comm 6' .50), Failure to submit this form may result in penalties as speCified In Comm 50,26/Comm 61.23
and/or local ordinances. This form must be submitted prior to the plan approval expiration date or another submittal may
be required.
Gen9rallnstrnctions~ Prior to the initial occupancy of new buildings or additions and the final occupancy of
<.Jal::!rf;1(j existing buildings, submit this completed and signed form to:
· The municipal building inspection office (refer to the plan approval letter for agency ilddres8 lDSt
· SafQty and Buildings. 10541 N Ranch Road Hayward, Wi. 54843
Note: If the review was done by the municipality, the compliance statement goes only to the municipal building
inspector. A copy is not needed by Safety & Buildings. .
Pl!~nallnfomlatlon you provide may be u~d mr ~col\dary pUI'pC!e$ [Privacy law, $ 15.04 (1)(m)1.
1. Jl~9;JECT INFORMATION: Please fill In the following with information from your plan approval letter.
~~f\ &Number S~ ,.1,.....~??d"b Project Name St/1han r./ ~$Pt-f-e ~
Site Number /
Site location (number & street) I'1Q W. /ttl~ AVe-
~Cjty 0 Villa~ 0 Town of t)"i(;,k;5h Counlyof ~h~eb":7d'
2. PURPOSE OF THIS STATEMENT: (Check Box A, B, C, or D to Indicate purpose and complete any other
applicable boxel:l and information. Attach additional pages if neceslSary.)
Check those which apply: )(SUilding Objed ID # 0 HVAC ObjecllD #
o Ughting Object 10 #
vI 1'f)\~ <<az.-. The following Item. am not in complla~ and must be addressed:
.-( ~ \.1..-. INt,ItN /JC'f" (,e/l,// t.A; t5 Jrl//"'-P vYeJ.)
~ '#':: \,~..) B) 0 Statement of Noncompll8nce
w.fV'~~C? Du~ II) IhI! {Q\lowIngIi5\ed llioIallOl\!;, \his prolettlt not ready tor oc.cupancy:
t~ 04-}
w,v-.-- C) 0 Supervfslng Professional WIthdrawn From Project (lJ$e A or B Ilbo\lll! 10 IndIcate proied stlllus II!: ofti'll!; <lale.)
D) 0 P~JectAba"doned
3. SU~E VISING PROFESSIONAL 51 HAT RE FO :
Bulllllng [J HVAC 0 Lighting
am~ (please pJlnt or lyp
Phone number 1.1;I/'L/QlJd CustomerlD# 97CJ tq 2,
o Partial Completion
Description of Portion ~rnpleted
A) )( Statement of Substantial Compliance
To the best of my knowledge, belief, and based 01'1 On!lite observation, construction of the following building Gnd/of HVAC
items applicable to this project have been completed in SUbstantial compliance with the approved plans and spedflC8tlons. .
D 8UILDlNGlLIGHTlNG ITEMS
1. Slructurlll system including JutlmlUal and erection of 1111 building compQnents
(Iruss8S, pf1tcast. melal building. alc.)
2. FlI'8 protectioo sysl~ms (Rprinklel"S. alarms, smok& detactols) designed, inslalled.
and \ested (including toIW9rd ftQW on bade ftQW devices) by approprlat&ly
reglsltHvd profess!onal$
3. Shaft IInd l:talrwllY anclQ$ure
4. ExllS lnduding exIt and dllectionalllgllls
5. Fire-resillbve construction. enclosure of hazards. fire walls. labeled doors. class [J HVAC ITEMS
of construction. fire slopped penelmtioos
S. SlInllaUon sy$tem (toll&t:s. sinks. drinking radlltles)
7, Barrier-free induding Comm 18 ell!valors and tills
8. Energy envelope reQuirements
9. All conditions of buildlnll plan approval and llppllcabl" wriances
10. EX1f1t1or lighting & conIrQI requirem&nls
, , . Interior li9hlinll & conlroll'llq\lif1tmenls
12. An conclilion(l of lighllng plan approval
lInd applicable variances
1. HVAC $~~m InCluding ftnalle~
2, All conditions of HVAC plan approval and
appliC:llble var111n~s
SHI).~'l:ZO 1R.04J:!(105)
~/"""" . ,.,." \.,,"...,......... '/
I e.6-ed
016170rzOZ6
IJ~IIHJav S~~H~S8M IHHJ VET:TT 90DZ'OZ Nor ~