City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903-1130
www.cLoshkosh.wi.us
April 3, 2006
Duane Helwig
Martin Ganther Group
4825 County Road A
Oshkosh, WI 54901
Denise Markee
150 N Koeller St LLC
601 Oregon St
Oshkosh WI 54901
Site:
Go Wireless
150 N Koeller Rd
Oshkosh WI 54902
For:
Description: Tenant space alterations
Object Type: Building only
Class of Construction: VB -1758 Sq Ft.;
Occupancy: M: Mercantile
Maximum No of Occupants: 50
Plan Number: S3-27-0306
Unsprinklered
The submittal described above bas been reviewed for confonnance with applicable Wisconsin Administrative Codes and
Wisconsin Statates. The submittal bas been CONDITIONALLY APPROVED. The owner, as defined in Chapter
101.01(10), Wisconsin Statates, is responsible for compliance with all code requirements
Key Item(s) I Conditions:
ANSI 303.4 Changes in level greater than Yz inch shall be ramped in compliance with Section 405 or 406.
Verify that entrance / exits meet accessibility requirements.
!BC 711.3 Any penetrations of fire rated assemblies are required to be protected with a listed firestopping
system that matches the rating of the wall assembly being penetrated. Copies of the firestopping systems
are required to be provided at the time of inspection. .
IBC 714.2.7 Fire doors shall be self closing or automatic closing. The door schedule included in the plans
does not show closers.
!BC 1209.1 Provide toilet room floors with smooth, hard, nonabsorbent surface extending minimum 6
inches up onto walls.
COMM 62.1109 (12) Where counters are provided for sales or distribution of goods or services, at least
one of each type provided shall be accessible.
Comm 2902 (4) Separate facilities shall not be required in mercantile occupancies in which the occupant
load is 50 or less. Note: if the occupancy changes in the future, the requirementsfor plumbingfn:tures
will need to be reviewedfor compliance.
'ÙOSllKOS! IMTSFS\USERS'.briann\2006 Comm Plan Revicw\S3-27-0306 150 N Kodler SI IJIdg Only.doc
Page 1 of2
!BC 2902..11 Table 2902 Drinking water is required to be provided, since no drinking fountain is shown
on plans a bottled water cooler is required to be provided.
Comm 61.30(3) 1 IMC 507.2 This plan review does not include heating, ventilation, or air
conditioning. HV AC plans are required to be submitted and approved prior to installation ofHV AC
equipment'
.
Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
authorized. representative prior to the work involved in the revision or modification being carried out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm 61.31(1).
MUN 30-35 (1)(5) All rooftop and ground level mechanical equipment and utilities shall be fully screened
ITom view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236-
5062 for additional information on screening requirements. All screening shall be properly anèhored in
place to resist wind loads. Additionally IBC 1608.8 Roofprojections - Drift loads due to mechanical
equipment, penthouses, parapets and other projections above the roof shall be determined in accordance
with Section 7.8 of ASCE 7. No HVAC permits will be issued without an approved screening plan
SUBMIT:
. Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to
be obtained prior to commencement of work.
In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or
additions shouid conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in tills
review shall relieve the designer of the responsibility for designing a safe building, structore, or component.
Inquiries concerning this correspondence may be made to me at the number listed below or the address on tills letterhead.
Respe~
4??~
Building Systems Consnltant