HomeMy WebLinkAboutBuilding S3-27-0306 ~ OJHKOfH ON 1"E WATER City of Oshkosh Division of Inspection Services 215 Church Avenue PO Box 1130 Oshkosh WI 54903-1130 www.cLoshkosh.wi.us April 3, 2006 Duane Helwig Martin Ganther Group 4825 County Road A Oshkosh, WI 54901 Denise Markee 150 N Koeller St LLC 601 Oregon St Oshkosh WI 54901 Site: Go Wireless 150 N Koeller Rd Oshkosh WI 54902 For: Description: Tenant space alterations Object Type: Building only Class of Construction: VB -1758 Sq Ft.; Occupancy: M: Mercantile Maximum No of Occupants: 50 Plan Number: S3-27-0306 Unsprinklered The submittal described above bas been reviewed for confonnance with applicable Wisconsin Administrative Codes and Wisconsin Statates. The submittal bas been CONDITIONALLY APPROVED. The owner, as defined in Chapter 101.01(10), Wisconsin Statates, is responsible for compliance with all code requirements Key Item(s) I Conditions: ANSI 303.4 Changes in level greater than Yz inch shall be ramped in compliance with Section 405 or 406. Verify that entrance / exits meet accessibility requirements. !BC 711.3 Any penetrations of fire rated assemblies are required to be protected with a listed firestopping system that matches the rating of the wall assembly being penetrated. Copies of the firestopping systems are required to be provided at the time of inspection. . IBC 714.2.7 Fire doors shall be self closing or automatic closing. The door schedule included in the plans does not show closers. !BC 1209.1 Provide toilet room floors with smooth, hard, nonabsorbent surface extending minimum 6 inches up onto walls. COMM 62.1109 (12) Where counters are provided for sales or distribution of goods or services, at least one of each type provided shall be accessible. Comm 2902 (4) Separate facilities shall not be required in mercantile occupancies in which the occupant load is 50 or less. Note: if the occupancy changes in the future, the requirementsfor plumbingfn:tures will need to be reviewedfor compliance. 'ÙOSllKOS! IMTSFS\USERS'.briann\2006 Comm Plan Revicw\S3-27-0306 150 N Kodler SI IJIdg Only.doc Page 1 of2 !BC 2902..11 Table 2902 Drinking water is required to be provided, since no drinking fountain is shown on plans a bottled water cooler is required to be provided. Comm 61.30(3) 1 IMC 507.2 This plan review does not include heating, ventilation, or air conditioning. HV AC plans are required to be submitted and approved prior to installation ofHV AC equipment' . Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve rules under this code and which are made to construction documents that have previously been granted approval by the department or its authorized representative, shall be submitted to the office that granted the approval. All revisions and modifications to plans shall be approved in writing by the department or its authorized. representative prior to the work involved in the revision or modification being carried out. A revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with Comm 61.31(1). MUN 30-35 (1)(5) All rooftop and ground level mechanical equipment and utilities shall be fully screened ITom view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236- 5062 for additional information on screening requirements. All screening shall be properly anèhored in place to resist wind loads. Additionally IBC 1608.8 Roofprojections - Drift loads due to mechanical equipment, penthouses, parapets and other projections above the roof shall be determined in accordance with Section 7.8 of ASCE 7. No HVAC permits will be issued without an approved screening plan SUBMIT: . Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional shall file a compliance statement form SBD-9720 with this office. A copy of the approved plans, specifications, and this letter shall be on-site during construction. All permits are required to be obtained prior to commencement of work. In granting this approval the City of Oshkosh Inspection Services Department reserves the right to require changes or additions shouid conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in tills review shall relieve the designer of the responsibility for designing a safe building, structore, or component. Inquiries concerning this correspondence may be made to me at the number listed below or the address on tills letterhead. Respe~ 4??~ Building Systems Consnltant (920) 236-5051 Mpnday - Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M. bnoe@ci.oshkosh.wi.us cc: Property file Fee Required $ Fee Received $ Balance Due $ 320.00 320.00 0.00 \\OSHKOSIIMISFS\USERS'.b,iannI2006 COffin> PI\m R.,iew'.S3-27,0306 ! 50 N Koelle, Si Bldg Only,do, Page 2 of2