HomeMy WebLinkAbout0118539-Plumbing (interior)
~
OSHKOSH
ON THE WATER
Job Address 2325 HICKORY CT
CITY OF OSHKOSH
No
118539
PLUMBING PERMIT - APPLICATION AND RECORD
Owner MARCIA R KONRAD
Create Date 03/16/2006
Contractor SBS PLUMBING LLC
Category 410 - Residential-Interior
Plan
Bathtub 3 Shower 1 Water Sollner 0 Wai!.S!. ------2 Shamp Sink 0
Whirlpool 1 Floor Drain -----.!. Local Waste ------2 Ice Chest 0 FlrlWst Sink 0
Lavatory 3 Lndry Tray 0 Clothes Wshr 1 Exam Sink ------2 Catch Basin 0
Toilet -------1 Disposal -----.!. Bidet ------2 Sculry Sink 0 Wash Ftn 0
Res. Sink 1 Dishwasher 1 Beer Tap ------2 Hand Sink ------2 Urinal 0
Bar Sink 0 Sump Pump 1 Lab Sink 0 Plaster Sink 0 Standp Rec 2
Water Heater 1 Classrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker 0
Site Drain 0 Breakrm Sink ------2 Dip Well 0 F Prep Sink ------2 Gar Drain 0
Roof Drain 0 Ejector/Grind 0 Drink Ftn 0 Serv Sink ------2 Soda Disp 0
Misc. 0
Fixtures
Coffee Maker ------2
Int Grease Trap ------2
Ext Grease Trap ------2
RPZ Valve 0
Eye Wash Statn 0
Wtr Sewer Mtrs ------2
Deduct Meters ------2
Wtr Usage Mtrs ------2
Use/Nature
of Work
rrn, ~~, "" .^,ffi "ffim
Size
Material
Type
#
Conn. Type
Sanitary Sewer
0
0
0
0
0
0
0
0
0
0
Storm Sewer
Water Service
$7,185.00
Plan Approval
$0.00
Permit Fees
0
0
0
0
0
$140.00 0 Permit Voided I
Parcelld #
1526190800
Valuation
Issued By
Date 03/16/2006
In the performance of this work, i agree to perform all work pursuant to rules governing the described construclion.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the
easement holder(s) and to secure any necessary approvais before starting such activity.
Signature
Date
Address PO BOX 3904
AgenVOwner
OSHKOSH
WI 54903 - 3904
Telephone Number 920-410-5933
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
WATER CALCULATION WORKSHEET FOR ~~~ I 232.5 f/;d::cny
NMlfIAOOIĆSS Of' ÞROJ!'::or
c.¡,
----'--..
I tNFOR;~~ION REQUIRED TO CALCULATE WATER SERVICE SIZE l
r 1, Demand of building in- gallons p~r minute. '" ". ,', WSFU's .2.5'_- " (GPMì ...~...._.. ¡
~' Difference in !'Itain 6r external pressure tånk to building valve. (fee!) I
3. Size of the watermeter. (When applicable) 518-_.3/4" _.f!5i;J1.1fZ' __,2"_,3" __,4" --' 6",_, I
4, Dave loped lengtl) frommal,'nor ex, te,malPressure ta nk to building wnlro, I valve. (fee, 1(, ,.5~L, ' --' J
5. low pressure at main 10 street or ext",mal pressure tank. (psig) . .kfJ.:__,
----
CALCULATE WATER SERVICE PRESSURE lOSS
6.
low pressure al main in street or extemal pressure tank. (value of II 5 above)
Wai~r service di"met~ I!; .1':6--' Material is ~!&Ì.¥~--'-' Pressure 10$5
per 100ft" ~b. P$i. X~(decima!equivalentof$ervicelength,j,e.; 65ft" .65)
7.
(Subtract line 7, from line 6,)
%
subtotal S~,() <¡ ..
Deteimtne pressure gain or loss due to elevation,
(multiPly the value 01#;2 ;¡bove by .434) value of $" ~
Available pressure after the bldg, contra,l vatve, (Subtract or add lin" 8, Eoter in "8".) subtotal ,?,!-.:..'il... '"
B.
9,
CALCULATE THE PRESSURE AVAILABLE FOR UNIFORM lOSS (VALUE OF "A")
B.
Available pressure after the bldg. control valve. (from "9" above)
Pressure loss ofwaler meter (when meter is required or install9d)
Value of "13"
c.
Value of 'C-
(Subtract line C. from line B.)
subtotal
D.
Pressure a(controlling fixture,
(Controlling flJ(ture is T"/",d<r:;' !.ö"""
Value of '0"
-.J
(Subtract the value of D.)
subtotal
E.
Diflerence in'elevation between lhe building control valve
and IheCönlrotfing.fixlure in feel ~ X .434 psilfl
Value of 'E"
(Subtract the value of E.)
subtotal
F.
Pressure loss due to water treatment devices, instantaneous
water heaters and backflow preventers Which serve the
controlling fixture,
(Pressure loss due to )
(Subtract the valUe of F,)
subtotal
Value of "F"
G.
Developed length from building control valve to conlrOfling
fixture in feet~,:"'" X 1.5
Value of "G" 1M. 5"'.
." 5 13
(Divide by the value of G.)
(Water distribution piping material is T y....I1..!S1~--)
subtotal
A
Pressure available for uniform loss
Multiply by
"Au"
$I"""".'"""'"
S' 2, '136
2.,
5°'6'36
'2.0
'30<6;36
:L7?L
'25',2';; z
25,
f;Z-
-...1.Q.Q.....
'2.>