HomeMy WebLinkAbout0118444-HVAC
~
OSHKOSH
ON THE WATER
Job Address 100NMAINST
CITY OF OSHKOSH
No
118444
HVAC PERMIT - APPLICATION AND RECORD
Owner
AKO OSHKOSH/PARKVIEW OSHKOSH/O~
Create Date 03/09/2006
Plan R3-107-1105-H
Contractor CONDON TOTAL COMFORT
U~~
Fuel 1,11 Gas
System ø New
~ Forced Air U Radiant
U Electric I 1 Hot Water
Chimney Type r) Chimney A () Chimney B
Heat Loss . As Approved ( ) Existing
BTU Rate . As Per Plan () Variable
Category 512 -Ind. & Comm-Both
1"'-1 Electric
1 I Solar
1 I Solid
0 Other
~ NC I ~ Vent
I 1 Con. Burner 1
. Not Applicable
n Replace
U Steam
U Supp!.
e ) Direct Vent
I
0 NotAppliceble
( ) Other
Value
Value
Use/Nature "Cranky Pats" - HVAC system as per State Trans ID # 1235009 - excludes Kitchen Exhaust system. Late Permit --ADDITIONALLY A
of Work SEPARATE REVIEW AND SUBMITTAL IS REQUIRED TO COMPLY WITH LOCAL SMOKING ORDINACE REQUIREMENTS.
Fees: Valuation
$16,400.00
Plan Approval
$0.00
Permit Fee Paid
$438.00
Date 03/09/2006
Issued By:
0 Permit Voided 1
Parcelld # 0800570000
In the performance of this work, I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which It is not a party, if you perform the work
described In this permit applicetion within an easement, the City strongly urges the permit applicent to contact the easement
holder(s) and to secure any necessary approvals before starting such activity.
Signature
Date
Agent/Owner
Address
PO BOX 184
RIPON
WI 54971 -184
Telephone Number
920-748-5050
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
(t)
OJHKOfH
City of Oshkosh
Division of Inspection Services
215 Church Avenue
PO Box 1130
Oshkosh WI 54903-1130
www.cLoshkosh.wLus
ON 'HE WATER
March IS, 2006
Paul Sobieck
Milwaukee Stove & Furnace
2442 Hutson Road
Green Bay, WI 54303
100 Block LLC
100NMainSt.
Oshkosh, WI 54901
Site:
Cranky Pats
IOONMainSt
Oshkosh WI 54901
For:
Description: Kitchen Exhanst Systems
Object Type: HV AC only
Class of Construction: llA - 3400 Sq Ft.;
Occupancy: A: Assembly
Plan Nnmber: R3-I07-1105-H2
sprinklered
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and
Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in Chapter
101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements
Key Item(s) / Conditions:
.
IMC 302.1 The building or structure shall not be weakened by the installation of mechanical systems.
VerifY that existing structure is capable ofsupportíng the additional weight of the proposed rooftop
equipment.
.
IMC 304.1 Equipment and appliances shall be installed as required by the terms oftheir approval, in
accordance with the conditions of the listing, the manufacture's instructions and this code.
IMC 401.5 Opening Location Outside air exhaust and intake openings shall be located a minimum of 10
feet (3048 mm) from lot lines or buildings on the same lot. Where openings front on a street or public way,
the distance shall be measured to the centerline of the street or public way.
IMC 401.5.1 Mechanical and gravity outside air intake openings shall be located a minimum of 10 feet
from any hazardous or noxious contaminant such as vents, chimneys, plumbing vents, streets, alleys,
parking lots and loading docks.
IMC 403.1 The amount of supply air shall be approximately equal to the amount ofretum and exhaust air.
Provide interlock with exhaust systems.
mc 904.11.2 System Interconnection The Interconnection of the fire suppression system shall
automatically shut down the fuel or electrical power supply to the cooking equipment. The fuel and
electrical supply reset shall be manual.
lhbri~m'20()(i Comm Phm Revjew\lU.1O7-l1O5-.1J2
s, Kitc),"n Hoode."",;
Page I of2
1
I
L
Comm 61.31(4) Revisions to approved plans. All proposed revisions and modifications which involve
rules under this code and which are made to construction documents that have previously been granted
approval by the department or its authorized representative, shall be submitted to the office that granted the
approval. All revisions and modifications to plans shall be approved in writing by the department or its
authorized representative prior to the work involved in the revision or modification being canied out. A
revision or modification to a plan, drawing or specification shall be signed and sealed in accordance with
Comm61.31(1).
MUN 30-35 (1)(5) All roof top and ground level mechanical equipment and utilities shall be fully screened
from view of any street or residential zoning district. Contact David Buck - Associate planner (920) 236-
5062 for additional information on screening requirements. All screening shall be properly anchored in
place to resist wind loads. Additionally mc 1608.8 Roofprojections - Drift loads due to mechanical
equipment, penthouses, parapets and other projections above the roof shall be determined in accord,ance
with Section 7.8 of ASCE 7. A screening plan for the make-up air unit is required to be approved prior
to HVAC permit being issuedfor this work.
City of Oshkosh Municipal Ordinance Section 14-1.2 "Smoking prohibited inside restarants"
Note: This plan has not been reviewed for complete compliance with this ordinance, as it does not include
information that addresses all the requirements for review. If there is a desire to create a separately
ventilated smoking room, additional plans are required to be submitted for review.
SUBMIT:
. Comm 61.50 (4) Supervision. Prior to the initial occupancy of an alteration the supervising professional
shall file a compliance statement form SBD-9720 with this office.
A copy of the approved plans, specifications, and this letter shall be on-site during construction. All pennits are required to
be obtained prior to commencement of work.
In granting this approval the CitY of Oshkosh Inspection Services Department reserves the right to require changes or
additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this
review shall relieve the designer of the responsibilitY for designing a safe building, structure, or component.
Inquiries concerning this correspondence may be made to me at the number listed below or the address on this letterhead.
~
Building Systems Consultant
(920) 236-5051 Monday-Friday 7:30 A.M. to 8:30 A.M and 12:30 A.M to 1:30 P.M.
bnoe@ci.oshkosh.wi.us
cc: Property file
Fee Required $
Fee Received $
Balance Due $
230.00
230.00
0.00
n,'briann'"OO6 Connn PI", Rooiow\R3-!O7.IIG5-H2 100 N \b, 51 Kitohm noolkd",'
Page2of2
03/03/2006 FRI 8:59 FAX 9204260389 Ganther - 2nd Floor
~ 001/003
GANTHER
CONSTRUCTION
Since 1900
FAX
To: Oa.V¡ d ßIA..c.. k.
Company: (.;"'7 or OSkkc:.",,-,
Phone: 236 - Só C;).
Fax: :2 '1' - SfS> $ '3
R~~n~: Cr~~7 p~+~
From:
Brian LaFrinì~
e-mail: blafriniere@ga.other.com
Pages: SJ I",-~) ~'.Iel""
Date: "3/~/Ob
I' ~
- /<:76 N, /J/f",},^ Sf-.
Da.v:-'ð,
A H-o..c.-he.cl o-õ-e. ft~s Sh.~v/I't1.:J' the. HVAc.
u."'~+ v./'€:., ~FKe- o..ÞO><..C.'t c>'" the PIM!!';(\{!...
-:¡:.;::- «::>v- l,o..v€.- o.."'Y ~ ""e-s '¡('-9'M -plel?>..';,e Co.. {L
We. wo..Jd, liKe- to. JE.+ r\e;>+'\~e ~-þ O-ff>tofAl
ò~ +~"-;j to ; t'..3,.,e ç it L@I/I.S Æ SA p.
-r- ~..kG J
ßr.~'^'
I"
I
í
Ganther Construction, Inl:.
~..&~
Brian LaFrinierc
CONSTRUCTIO1'< MANAGERS
GENERAL CONTRACTORS
DESlGNIBUILDILEASE BACK
Office: (920) 426-4774
Fax; (9%0) 426-4788
E-mail: ganther@g81ither.com
ProjectVision www.ganther.com
4825 County Road A
Odlkosh, WI 54901
03/03/2006 FRI 9: 00 FAX 9204260389 Ganther - 2nd Floor
@002/OO3
- -/[r - ~
1&0 ¡V, /V1.o.,,'r--, Sf.
90-<' 4i"\'o-\. oS ~+e.. Plo..Y"\
80 FT.
-. -
/v1 A :J: IV
fAIN STREET
:r
~
...
'"
.'"1
/
~
$ 0
~ g~
5< ¡gJ .i
~
If ....",,1
SóO-' e. I =-...""
/0
I~
l¡;j
I~
I
I~
I~
I~
Ie::
Jl::tj
03/03/2006 FRI 9: 00 FAX 9204260389 Gantber - 2nd Floor
CõQ.\S\ k ì' Ç>~ + \.s
@003/003
I ðO IV. lÞlo..~'f'; St.
::¡:
d
~
<:
,-I
~
..$c...-t~ /'1:::: 10 I
28.
,2
liS
,~
I~
:~
;~
p
~
:r
<J¡-
'r
l.
wv
0- ..,
. ""
'I< ><
WtJ
~-4::
..;.' x" .
v -
.. ~
":r 5"'-
t.i;ur
:S'" .,..
-0 &
~ ~
:I
'"
G
'\
()
;,
¡
:.
,
ç
j
g
~
-þ-
DEPARTMENT OF PUBLIC WORKS
215 Church Avenue
P.O. Box 1130
Oshkosh, Wisconsin 54903-1130
Ph. (920) 236-5065
Fax (920) 236-5068
(t)
O[!-;i~ 9tH
MEMORANDUM
Date:
March 2, 2006
To:
Darryn Burich
James Rabe
From:
RE:
Cranky Pat's -100 N. Main St.
. Darryn,
I met with Brian from Ganther Construction onsite at 100 N. Main St. this morning to discuss the proposed
location of the HV AC unit at the northwest corner of the building. There was some question as to whether this
unit would conflict with the storm water detention area to the north ofthe building. Based upon the site visit, and
discussion with Dave Patek, Director of Public Works, we approve of the proposed location, with the following
condition:
.
The detention area adjacent to the current construction has been constructed with the correct amount of
runoff storage per the approved Storm Water Management Plan for the site.
If you have any questions regarding this matter, please do not hesitate to contact us.
James Rabe
Civil Engineer I
cc:
David Patek, Director of Public Works
Ed Potempa, Civil Engineer II
Allyn Dannhoff, Director of Inspection Services
I:\EngineeringISWMP - (Non-residential)I!OO N. Main Stlcfanky Pats
Restaurant Memo 03-02-2006.doc
Page 1 of!